Section 1606. Filing by Manufacturers; Listing of Appliances in the MAEDbS.

(a)   Filing of Statements.

Text

Description automatically generated with medium confidence

Each manufacturer shall electronically file with the Executive Director through the MAEDbS a statement for each appliance that is sold or offered for sale in California. The statement shall contain all of the information described in paragraphs (2) through (4) of this subsection and shall meet all of the requirements of paragraph (1) of this subsection and all other applicable requirements in this Article.

The effective dates of this section shall be the same as the effective dates shown in section 1605.1, 1605.2 or Section 1605.3 of this Article for appliances for which there is an energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in section 1605.1, 1605.2, or section 1605.3 of this Article

For appliances with no energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in Section 1605.1, 1605.2, or Section 1605.3, of this Article the effective date of this section shall be one year after they are added to Section 1601 of this Article, unless a different effective date is specified.

 

Exceptions to Section 1606(a) of this Article: Section 1606(a). is not applicable to:

(1)  external power supplies,

(2)  small electric motors, or

(3)  à la carte chargers meeting the EXCEPTION noted in Section 1605.3(w)(2) of this Article.

(4)  General service lamps

 

(1)   General Rules.

(A)  Format and Categories. Each statement shall be in a format (including but not limited to computer formats) and in categories specified by the Executive Director.

(B)  When Different Statements are Required. The Executive Director may establish, modify, and enforce schedules for the submittal of statements where it is reasonably necessary for orderly processing of submittals, for example when manufacturers or third parties often submit many statements simultaneously.

(C)  Asterisks in Model Numbers. In filing any statement, the manufacturer may use asterisks as a substitute for letters, numbers, blanks, or other characters in the model number, provided that an asterisk (i) shall be used only for a part of the model number that does not indicate energy consumption, energy efficiency, water consumption, or water efficiency, or a design or feature affecting such efficiency or consumption; (ii) shall represent a single letter, number, blank, or other character at the asteriskʹs location in the model number; and (iii) shall not be used for any of the first four letters, numbers, blanks, or other characters in the model number.

(D)  Different Functions. Except as provided in section 1606(a)(1)(G), of this Article if the same appliance is sold or offered for sale as more than one type of appliance shown in Table X (for example, if the appliance can serve both water heating and pool heating functions), the manufacturer shall submit a separate statement for each model of that appliance type. Each appliance type for which a statement is submitted must match all the common identifiers shown in Table X.

(E)  Multiple Statements. A manufacturer may electronically file statements through the MAEDbS for more than one appliance in a single submittal to the Executive Director. If a submittal contains statements for more than one appliance, there shall be only one statement for each appliance, except as provided in sections 1606(a)(1)(D) and 1606(a)(1)(G).of this Article. The Executive Director shall allow multiple statements to be submitted on the same sheet of paper or in the same electronic file under conditions she or he determines are reasonably necessary to ensure accuracy and compatibility with the MAEDbS

(F)  Split System Central Air Conditioners. The statement for split system air conditioners shall be for the combination of the compressorcontaining unit and the noncompressorcontaining unit tested under section 1604(c) of this Article.

(G)  Combination SpaceHeating and WaterHeating Appliances. Manufacturers of combination spaceheating and waterheating appliances shall file two statements for each such appliance. The first statement shall contain the information listed in Table X for combination spaceheating and waterheating appliances, and all other information shown in Table X for “all appliances;” and the second statement shall contain the information listed in Table X for the primary function of the appliance according to the determination required by sections 1605(e) and 1605(f), of this Article and containing all other information shown in Table X for “all appliances.” Each appliance type for which a statement is submitted must match all the common identifiers shown in Table X.

(H)  Portable Air Conditioners. A manufacturer shall file two statements for a single model of portable air conditioner if the model is sold or offered for sale in California with both single-duct and dual-duct configuration options. One statement shall be for the single-duct configuration, and the other statement shall be for the dual-duct configuration.

(I)    Air Filters. The statement for air filters shall be for each basic model of air filter tested under section 1604(c)(3) of this Article

 

(2)   Manufacturer Information.

(A)  The name, address, telephone number, email address and, if available, fax number, and URL (web site) email address of the manufacturer; provided, however, that if a parent entity is filing on behalf of a subsidiary entity, if a subsidiary entity is filing on behalf of a parent entity, or if an affiliate entity is filing on behalf of an affiliate entity, then each entity shall be clearly identified and the information shall be provided for both entities.

(B)  The name, address, telephone number, email address and, if available, fax number of the individual to contact concerning the statement pursuant to section 1606(a)(4) of this Article. There shall be only one individual to contact for each category (box) in the “Appliance” column of Table X, except that the individual may, during his or her absence, delegate his or her duties in this regard.

(C)  The name, address, telephone number, e-mail address and, if available, fax number of the person signing the declaration pursuant to section 1606(a)(4) of this Article.

(3)   Testing and Performance Information.

(A)  A statement that the appliance has been tested in accordance with all applicable requirements of Sections 1603 and 1604 of this Article If Section 1604 provides more than one test method that may be used, the manufacturer shall identify which method was used.

EXCEPTION 1. to Section 1606(a)(3)(A) of this Article:

For state-regulated compressors, the manufacturer shall submit a statement that the appliance has been tested in accordance with all applicable requirements of sections 1603 and 1604 of this Article, or that the appliance has been rated according to an alternative efficiency determination method (AEDM) in accordance with all applicable requirements of section 1604(s) of this Article

(B)   The name and address and, if available, telephone number, fax number, URL (web site) address, and e-mail address of the laboratory or other institution where the testing required by sections 1603 and 1604 of this Article was performed.

(C)   The applicable information listed in Table X; provided, however, that submittal of information marked with "1" is voluntary for federally regulated appliances, and that submittal of information marked with "2" is voluntary for state-regulated appliances. Where there is text in the "Permissible Answers" column, the information provided must be one of the answers shown. If the text in the "Permissible Answers" column states "other (specify)," the information provided must be a specific response for the "Required Information" category (e.g., a response of "other" is not acceptable).

 

EXCEPTION 2. to Section 1606(a)(3)(A) of this Article:

For integral cartridge-filter pool pumps and integral sand-filter pool pumps manufactured on or after July 19, 2021, in lieu of the statement required in section 1606(a)(3)(A) of this Article, a statement that the appliance meets the energy design requirements of sections 1605.1(g)(7)(C) and 1605.1(g)(7)(D) of this Article.

 

EXCEPTION 3 to section 1606(a)(3)(A) of this Article:

For residential pool pump and motor combinations and residential replacement pool pump motors, in lieu of the statement required in section 1606(a)(3)(A) of this Article, a statement that the appliance meets the design requirements of section 1605.3(g)(5)(A) and 1605.3(g)(5)(B) of this Article.

 

Exception 1. to Section 1606(a)(3)(C) of this Article:

If an appliance has an alternative test procedure pursuant to  section 1603(c)(1) of this Article, or an alternative assessment method specified pursuant to section 1603(c)(2)(A) of this Article, then the statement shall include:

(1) the following information from Table X: Manufacturer's Name, Brand Name, Model Number, and Regulatory Status; and

(2) all information from Table X that is applicable to the appliance and that is produced during the alternative test procedure or the alternative assessment method; and

(3) all other energy performance information produced during the alternative test procedure or the alternative assessment method.

 

Exception 2. to Section 1606(a)(3)(C) of this Article:

If the Executive Director has specified that there is no test method for an appliance pursuant to section 1603(c)(2)(B) of this Article, then the statement shall include the following information from Table X: Manufacturer's Name, Brand Name, Model Number, and Regulatory Status.

 

Exception 3. to Section 1606(a)(3)(C) of this Article:

Manufacturers of state-regulated LED lamps and LED versions of state-regulated small-diameter directional lamps may certify estimated values for rated lifetime until testing per section 1604 of this Article is complete. When reporting estimated values, the certification report shall describe the prediction method, which must be generally representative of the methods specified in 10 C.F.R. Appendix BB to subpart B of part 430, “Uniform Test Method for Measuring the Input Power, Lumen Output, Lamp Efficacy, Correlated Color Temperature (CCT), Color Rendering Index (CRI), Power Factor, Time to Failure, and Standby Mode Power of Integrated Light-Emitting Diode (LED) Lamps.” Manufacturers shall maintain records of the development of all estimated values and any associated initial test data. Manufacturers shall update the certification in the MAEDbS upon completion of the required test procedures for rated lifetime.

 

(D)  How Tested Data Must Be Reported.

1.   For any numerical value required by Table X that is produced by a test specified in section 1604, of this Article the reported value shall be no higher for the value for which the consumer would prefer a high number, and no lower for the value for which the consumer would prefer a low number, than the values obtained by testing; unless different specific instructions are specified in the test method specified in section 1604 of this Article.

2.   For any numerical value required by Table X that is produced by calculation from measured numerical test results, the reported value shall be no higher for the values where the consumer would prefer a high number than the exact result of the calculation, and no lower than the exact result of the calculation where the consumer would prefer a low number, than the values obtained by calculating, unless different specific instructions are specified in the test method specified in Section 1604 of this Article.

3.   Manufacturers may report:

a. numbers higher than tested values, where the consumer would, all other things being equal, prefer lower values (or is indifferent); and

b. numbers lower than tested values, where the consumer would, all other things being equal, prefer higher values (or is indifferent).

Example: An air conditioner is tested using the appropriate test method specified in Section 1604, and the test method does not include specific instructions about the precision of reporting.

   Cooling capacity is measured as: 36,014 Btu per hour.

   For cooling capacity, consumers prefer higher values.

   The manufacturer may not report any value over 36,014 Btu per hour.

   The manufacturer chooses to report 36,000 Btu per hour.

   Electrical energy use is measured at 3,487 watts.

   For electrical energy use, consumers prefer lower values.

   The manufacturer may not report any value under 3,487 watts.

   The manufacturer chooses to report 3,500 watts.

   Using the data the manufacturer chooses to report, EER = 36,000/3,500 = 10.285714.

   For EER, consumers prefer higher values.

   The manufacturer may not report any value of EER over 10.285714 (if EER is reported with only one decimal place, the maximum value would be 10.2).

   The manufacturer chooses to report EER = 10.2 Btu per watt hour.

   If the manufacturer had chosen to report the cooling capacity as 36,014 Btu per hour, and the electrical energy use as 3,487 watts, the calculated EER would have been 36,014/3,487 = 10.328076. In this case the manufacturer could not report any value of EER over 10.328076 (if EER is reported with only one decimal place, the maximum value would be 10.3).

 

Table X Data Submittal Requirements

 

A – Refrigerators, Refrigerator-Freezers, and Freezers

B - Room Air Conditioners, Room Air-Conditioning Heat Pumps, Packaged Terminal Air Conditioners, and Packaged Terminal Heat Pumps

C - Central Air Conditioners

D   Portable_Air_Conditioners

E   Gas and Oil Space Heaters and Electric Residential Boilers

F - Water Heaters

G - Pool Heaters, Portable Electric Spas, Residential Pool Pump and Motor Combinations, and Replacement Residential Pool Pump Motors

H - Plumbing Fittings

I - Plumbing Fixtures

J - Fluorescent Lamp Ballasts and Deep-Dimming Lamp Ballasts

K - Lamps

L - Emergency Lighting

M - Traffic Signal Modules

N - Luminaires and Torchieres

O - Dishwashers

P - Clothes Washers

Q - Clothes Dryers

R - Cooking Products and Food Service Equipment

S - Electric Motors

T - Distribution Transformers

U – None.

V - Computers, Computer Monitors, Televisions, Signage Displays, and Consumer Audio and Video Equipment

W - Battery Charger Systems

X – Landscape Irrigation Equipment

 

Table X- A
Refrigerators, Refrigerator-Freezers, and Freezers.
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

NonCommercial Refrigerators, NonCommercial RefrigeratorFreezers, NonCommercial Freezers

 

*Product Class

Category in Table A-2 or A3 (specify)

Access1, 2

Door, drawer, both door and drawer

Kitchen Unit1, 2

True, False

Refrigerator Volume

 

 

Freezer Volume

 

 

Total Volume

 

Adjusted Total Volume

 

Height

 

Width

 

Depth

 

Annual Energy Consumption (low)

 

Annual Energy Consumption (high)

 

Annual Energy Consumption (mean)

 

Antisweat Heater Switch

True, False

Refrigerant Type1, 2

Ozonedepleting, nonozone depleting

Insulation Type1, 2

Ozonedepleting, nonozone depleting

Selfcontained Commercial Refrigerators with or without doors, Selfcontained Commercial Refrigerator Freezers with or without doors, Self contained Commercial Freezers with or without doors, Selfcontained Commercial Refrigerators specifically designed for display and sale of bottled or canned beverages with or without doors, Remote Condensing Commercial Refrigerators, Remote Condensing Commercial Freezers, Commercial Ice Cream Freezers

(Note: units with multiple compartments must certify data for each compartment)

 

*Cabinet Style

Ice cream cabinet; milk or beverage cabinet; milk, beverage, or ice cream cabinet; undercounter cabinet; other reachin cabinet; passthrough cabinet; rollin or rollthrough cabinet; preparation table; buffet table; wedge case; work top table.

*Defrost System

Automatic, manual, partialautomatic

*Type

Icecream application, lowtemperature application, mediumtemperature application, pulldown application

Total Compartments (for hybrid models and refrigerator-freezers)

 

Equipment Family

Vertical open, semivertical open, horizontal open, vertical closed transparent, horizontal closed transparent, vertical closed solid, horizontal closed solid, service over counter

Condensing Unit Configuration

Remote, selfcontained

Multiple Compartments Number Code

 

Total Display Area (

TDA)

 

 

Total Volume

 

Height

 

Width

 

Depth

 

Anticondensate Energy Consumption (AEC) (for hybrid models and refrigerator-freezers)

 

Condensate Evaporator Pan Energy Consumption (PEC) (for hybrid models and refrigerator-freezers)

 

Defrost Energy Consumption (DEC) (for hybrid models and refrigerator-freezers)

 

Fan Energy Consumption (FEC) (for hybrid models and refrigerator-freezers)

 

Compressor Energy Consumption (CEC) (for hybrid models and refrigerator-freezers)

 

Lighting Energy Consumption (LEC) (for hybrid models and refrigerator-freezers)

 

Other Energy Consumption (OEC) (for hybrid models and refrigerator-freezers)

 

Daily Energy Consumption

 

Calculated Daily Energy Consumption (

CDEC)

 

 

Total Daily Energy Consumption (TDEC)

 

 

Refrigerant Type

Ozonedepleting, nonozonedepleting

Insulation Type

Ozonedepleting, nonozonedepleting

Automatic Commercial Ice Makers

 

*Equipment Type

Icemaking head, remotecondensing, selfcontained, both remotecondensing and remotecompressor

*Cooling Type

Air, water

*Ice Maker Process Type

Batch, continuous, cube other (specify)

Harvest Rate

 

 

Energy Consumption

 

Water Consumption

 

Ice Hardness Adjustment Factor (for continuous type models)

 

Water Dispensers

 

 

*Type

Bottle type; Bottle type with compartment; Pressure type, bubbler; Pressure type with compartment, bubbler; Pressure type, faucet; Pressure type with compartment, faucet, PointofUse

*Condenser Cooling Medium

Aircooled; Watercooled

*Style

Freestanding; FlushtoWall; Wall Hung; Wall Hung semirecessed; Remote; Recessed

*Refrigerated Compartment

 

Temperatures delivered

Cold only, cook (ambient) and cold, hot and cold

Cooling Capacity (gallons/hour)

 

Heating Capacity (6oz. cup per hour)

 

Standby Energy Consumption (kWh/day)

 

Walkin Coolers, and Walkin Freezers: Doors

 

Door Type

Passage door (medium temperature), passage door (low temperature), freight door (medium temperature), freight door (low temperature), display door (medium temperature), display door (low temperature)

Door surface area (ft2)

 

Transparent reach-in?

Door, window, both

Glass Type of Doors and Door Windows (if applicable)

1” triple pane insulated, 1” triple pane tempered, 2-pane Low-E Gas Fill, 3-pane gas fill, 3-pane heat reflective, 3-pane Low-E gas fill, 3-pane reflective gas fill, 3-pane heated, 3- pane unheated, none

Anti-sweat heater power draw (W per ft2 of door opening) (if applicable)

 

Door insulation R-value (if applicable)

 

All applicable design standards incorporated?

True, False

Daily energy consumption (kWh/day)

 

Equipped with a timer, control system, or other demand-based control reducing lighting power and/or heater wire and/or other electricity-consuming device?

Lighting, heater wire, other electricity-consuming device, lighting + heater wire, lighting + other electricity-consuming device, heater wire + other electricity-consuming device, all, none

Total rated lighting power (W) (if applicable)

c

Total rated heater wire power (W) (if applicable)

 

Total rated other electricity-consuming device power (W) (if applicable)

 

Walkin Coolers, and Walkin Freezers: Panels

Panel Type

Wall panels for walk-in coolers, ceiling panels for walk-in coolers, wall panels for walk-in freezers, ceiling panels for walk-in freezers, floor panels for walk-in freezers

R-value of wall insulation (if applicable)

 

R-value of ceiling insulation (if applicable)

 

R-value of floor insulation (if applicable)

 

Walkin Coolers, and Walkin Freezers: Refrigeration Systems

Refrigeration system Type

Dedicated condensing system medium temperature indoor; Dedicated condensing system medium temperature outdoor; Dedicated condensing system low temperature indoor; Dedicated condensing system low temperature outdoor; unit cooler medium temperature, unit cooler low temperature

Is outdoor dedicated condensing system also certified (for indoor dedicated condensing systems only?

True, False

Model number for outdoor dedicated condensing system (only applicable for indoor dedicated condensing systems where outdoor dedicated condensing system is also certified)

 

Refrigeration system net capacity (Btu/hr) (if applicable)

 

Evaporator fan motor horsepower (if applicable)

 

Condenser fan motor horsepower (if applicable)

 

All applicable design requirements incorporated?

True, False

Process cooling refrigeration system?

True, False

Annual Walk-in Energy Factor(AWEF)

 

Configuration tested for certification (if applicable)

Condensing unit only, unit cooler only, single package dedicated system, matched pair

Refrigerated

Bottled or Canned Beverage Vending Machines

 

 

Equipment Class (reporting of Combination A or Combination B for models manufactured on or after January 8, 2019)

Class A, Class B, Combination A,Combination B

Door Type

Glass front, closed front,

Machine use designation

Indoor, indoor / outdoor

Maximum Daily Energy Consumption at 75°F. Ambient Temperature

 

Standard Vendible Capacity

 

 

Low Power State – lighting

True, false

Low Power State – refrigeration

True, false

Low Power State – whole machine

True, false

OnSite Adjustable by Operator or Owner

True, false

Refrigerant Type

Ozonedepleting, nonozonedepleting

Insulation Type

Ozonedepleting, nonozonedepleting

Internal volume

 

Miscellaneous Refrigeration Products

Product Class

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12

Variable Defrost Control

True, False

Least time Between Defrosts (hours) (when “Variable Control” = True)

 

Max time Between Defrosts (hours) (when “Variable Control” = True)

 

Variable Anti-Sweat Heater Control

True, False

Heater Watts at 5%, 15%, 25%, 35%, 45%, 55%, 65%, 75%, 85%, and 95% humidity (Watts) (when “Variable Anti-Sweat Heater Control” = True)

 

Testing Conducted with Modifications to Standard Temperature Sensor Locations

True, False

Total Refrigerated Volume (ft3)

 

Total Adjusted Volume (ft3)

 

Annual Energy use (kWh/year)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-B
Room Air Conditioners, Room Air-Conditioning Heat Pumps,
 Packaged Terminal Air Conditioners, and Packaged Terminal Heat Pumps
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Room Air Conditioners and Room AirConditioning Heat Pumps

 

*Voltage

 

*Electrical Phase

1, 3

*Type

Room air conditioner, room air conditioning heat pump, casementonly room air conditioner, casementslider room air conditioner.

*Louvered Sides

Yes,

no

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Combined Energy Efficiency Ratio at 95°F

 

Standby and Off Mode Annual Energy Consumption

 

Heating Capability

Heat pump, electric resistance heating, heat pump and electric resistance heating, no heating capability

Refrigerant Type1

Ozonedepleting, nonozonedepleting

Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps

 

*Voltage

 

*Electrical Phase

1, 3

*Type

PTAC, PTHP

Size

Standard, nonstandard

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Energy Efficiency Ratio (EER) at 95°F

 

Heating Capability

Heat pump, electric resistance heating, heat pump and electric resistance heating, no heating capability

Heating Capacity (for models with heating capability only)

 

Electrical Input (for models with heating capability only)

 

Coefficient of Performance (for models with heating capability only)

 

Refrigerant Type1

Ozonedepleting, nonozonedepleting

Compressor Power1

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
3= Report both fields for split systems; either indoor or outdoor fan electrical input (not both) for single package models

Table X-C
Central Air Conditioners
 Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Air Filters manufactured on or after July 1, 2024

 

Length of tested air filter (inches)

 

Width of tested air filter (inches)

 

Depth of tested air filter (inches)

 

Face Area of tested air filter (inches)

 

Test Procedure used

AHRI Standard 680 (I-P)-2017, ANSI/ASHRAE Standard 52.2-2017

Face Velocity Utilized for the test procedure (feet per minute)

 

Minimum Efficiency Reporting Value (MERV) (if ANSI/ASHRAE Standard 52.2-2017 was used.)

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 N/A

Particle size Efficiency for 0.3 to 1.0 µm particle size

 

Particle size Efficiency for 1.0 to 3.0 µm particle size

 

Particle size Efficiency for 3.0 to 10 µm particle size

 

Airflow Rate value 1 (cubic feet per minute)

 

Airflow Rate value 2 (cubic feet per minute)

 

Airflow Rate value 3 (cubic feet per minute)

 

Airflow Rate value 4(cubic feet per minute)

 

Airflow Rate value 5-(cubic feet per minute) (Maximum Rated Airflow Rate if ANSI/ASHRAE Standard 52.2-2017 was used)

 

Calculated Airflow Rate value at an Initial Resistance of 0.1 inches water column (cubic feet per minute)

 

Initial Resistance at air flow rate value 1 (inches water column)

Test results to one-hundredths of an Inch of Water Column

Initial Resistance at air flow rate value 2 (inches water column)

Test results to one-hundredths of an Inch of Water Column

Initial Resistance at air flow rate value 3 (inches water column)

Test results to one-hundredths of an Inch of Water Column

Initial Resistance at air flow rate value 4 (inches water column)

Test results to one-hundredths of an Inch of Water Column

Initial Resistance at air flow rate value 5 (inches water column) (if ANSI/ASHRAE Standard 52.2-2017 was used)

Test results to one-hundredths of an Inch of Water Column

Final Resistance at the point where test is terminated and results determined (inches water column)

Test results to one-hundredths of an Inch of Water Column

Dust Holding Capacity at the maximum rated airflow rate as published by the manufacturer

Test results in multiples of one gram

*Coil Model Number with which Compressor was Tested (for split systems only)

 

*Type

Air conditioner, heat pump (heating and cooling), heat pump (heating only), heat pump (cooling only)

All Central Air Conditioners and Central AirConditioning Heat Pumps

*Energy Source for Cooling

Electricity, natural gas

*Energy Source for Heating

Gas, oil, electric heat pump, electric resistance, heat pump and electric resistance, none

*ARI Classification

 

*Voltage

 

*Electrical Phase

1, 3

Variable Refrigerant Flow

True, False

Heat Recovery (for Variable Refrigerant Flow models only)

True, False

Vertical Air Conditioner (for single package models only) (required on or after January 1, 2010)

True, False

Refrigerant Type1, 2

Ozonedepleting, nonozone depleting

Thermostatic Expansion Valve (for air source or aircooled models only)

Yes, no

Compressor Motor Design

Singlespeed, dualspeed, multiple speed, variablespeed

 

 

Seasonal Energy Efficiency Ratio (SEER)³

 

Cooling Capacity at 82°F³

 

AirCooled, Single Package CAC < 65,000 Btu/hour and

AirCooled, Split System CAC < 65,000 Btu/hour

Electrical Input at 82°F³

Degradation Coefficient at 82°F³

 

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Energy Efficiency Ratio (EER) at 95°F

 

Average Off Mode Power Consumption (Watts)

 

Spaceconstrained Product

Spaceconstrained; variable speed mini-split; small duct, high velocity; not spaceconstrained

 

 

Seasonal Energy Efficiency Ratio (SEER)

 

Cooling Capacity at 82°F³

 

AirSource, Single Package Heat Pumps < 65,000 Btu/hour and

AirSource Split System Heat Pumps < 65,000 Btu/hour

Electrical Input at 82°F³

Degradation Coefficient at 82°F³

 

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Energy Efficiency Ratio (EER) at 95°F

 

Average Off Mode Power consumption (Watts) (for models manufactured on or after January 1, 2015 only)

 

Heating Seasonal Performance Factor (HSPF3

 

Heating Capacity

 

Electrical input

 

Coefficient of Performance (COP) at 47°F (single package vertical heat pumps only)

 

Spaceconstrained Product

Spaceconstrained; variable speed mini-split; small duct, high velocity; not spaceconstrained

 

 

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Air-Cooled, Single Package CAC ≥ 65,000 and < 760,000 Btu/hour

Air-Cooled, Split System CAC ≥ 65,000 and < 760,000 Btu/hour

Energy Efficiency Ratio (EER) at 95°F (effective for models manufactured before January 1, 2018)

Integrated Part Load Value (IPLV) (effective for models manufactured before January 1, 2018)

 

Heating System Type1, 2

Gas, oil, electric resistance, none

 

 

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

Air-Source, Single Package Heat Pumps ≥65,000 and  < 760,000 Btu/hour; and

AirSource, SplitSystem Heat Pumps ≥65,000 and <760,000 Btu/hour

Energy Efficiency Ratio (EER) at 95°F (effective for models manufactured before January 1, 2018)

Integrated Energy Efficiency Ratio (IEER) at 95°F (effective for models manufactured before January 1, 2018)

 

Integrated Part Load Value (IPLV) If Applicable

 

Heating Capacity at 47°F

 

Electrical Input at 47°F

 

Coefficient of Performance (COP) at 47°F

 

Heating Capacity at 17°F

 

Electrical Input at 17°F

 

Coefficient of Performance (COP) at 17°F

 

 

 

Cooling Capacity at 95°F

 

Electrical Input at 95°F

 

EvaporativelyCooled Single Package CAC <760,000 Btu/hour and

EvaporativelyCooled Split System CAC <760,000 Btu/hour

Energy Efficiency Ratio (EER) at 95°F

Integrated Part Load Value (IPLV) If Applicable

 

Heating System Type1, 2

Gas, oil, electric resistance, none

 

 

Compressor Electrical Input (for models ≥65,000 Btu/hour only)

 

Indoor Fan Electrical Input (for models ≥65,000 Btu/hour only)

 

WaterCooled Single Package CAC < 760,000 Btu/hour and

WaterCooled, Split System CAC < 760,000 Btu/hour

Outdoor Fan Electrical Input (for models ≥65,000 Btu/hour only)

Cooling Capacity at 85°F Entering Water Temperature

 

Electrical Input at 85°F Entering Water Temperature

 

Energy Efficiency Ratio (EER) at 85°F Entering Water Temperature

 

Low Temperature EER at 70°F Entering Water Temperature (for models < 65,000 Btu/hour only)

 

Heating System Type1

Gas, oil electric resistance, none

 

 

Compressor Electrical Input (for models ≥65,000 Btu/hour only)

 

Indoor Fan Electrical Input (for models ≥65,000 Btu/hour only)

 

Water-Source, Single Package Heat Pumps< 760,000 Btu/hour and

WaterSource Split System Heat Pumps < 760,000 Btu/hour

Outdoor Fan Electrical Input (for models ≥65,000 Btu/hour only)

Cooling Capacity at 86°F Entering Water Temperature

 

Electrical Input at 86°F Entering Water Temperature

 

Energy Efficiency Ratio (EER) at 86°F Entering Water Temperature

 

Heating Capacity at 68°F Entering Water Temperature

 

Electrical Input at 68°F Entering Water Temperature

 

Coefficient of Performance (COP) at 68°F Entering Water Temperature

 

 

 

Compressor Electrical Input (for models ≥65,000 Btu/hour only)

 

Indoor Fan Electrical Input (for models ≥65,000 Btu/hour only)3

 

Ground WaterSource, Single Package Heat Pumps and

Ground WaterSource
Split System Heat Pumps

Outdoor Fan Electrical Input (for models ≥65,000 Btu/hour only)3

Cooling Capacity at 59°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

Electrical Input at 59°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

Energy Efficiency Ratio (EER) at 59°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

Heating Capacity at 50°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

Electrical Input at 50°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

Coefficient of Performance (COP) at 50°F Entering Water Temperature (for all sizes, including but not limited to models ≥ 240,000 Btu/hour)

 

 

 

Compressor Electrical Input (for models ≥65,000 Btu/hour only)

 

Indoor Fan Electrical Input (for models ≥65,000 Btu/hour only)3

 

GroundSource, Closed Loop, Single Package Heat Pumps and

GroundSource, Closed Loop, Split System Heat Pumps

Outdoor Fan Electrical Input (for models ≥65,000 Btu/hour only)3

Cooling Capacity at 77°F Entering Brine Temperature

 

Electrical Input at 77°F Entering Brine Temperature

 

Energy Efficiency Ratio (EER) at 77°F Entering Brine Temperature

 

Heating Capacity at 32°F Entering Brine Temperature

 

Electrical Input at 32°F Entering Brine Temperature

 

Coefficient of Performance (COP) at 32°F Entering Brine Temperature

 

 

 

Cooling Capacity – (cooling bin summary)

 

Gas Input While Cooling – (cooling bin summary)

 

GasFired Air Conditioners and Gas Fired Heat Pumps

Electric Input While Cooling – (cooling bin summary)

Cooling COP – Gas

 

Cooling COP – Electric

 

Heating Output – (heating bin summary)

 

Gas Input While Heating – (heating bin summary)

 

Electric Input While Heating – (heating bin summary)

 

Heating COP – Gas

 

Heating COP – Electric

 

 

 

Equipment Type

Aircooled, watercooled, water cooled with a fluid economizer, glycolcooled, glycolcooled with a fluid economizer, evaporatively cooled; chilled-water-cooled

Air Flow Direction

Downflow, horizontal flow, upflow

Computer Room Air Conditioners

 

Net Sensible Cooling Capacity (Aircooled, watercooled, glycolcooled, chilled-water-cooled models only)

Downflow Unit Power Input (watts) (Aircooled, watercooled, glycolcooled, chilled-water-cooled models only))

 

Downflow Unit SCOP (Aircooled, watercooled, glycolcooled, chilled-water-cooled models only)

 

Upflow Unit Power Input (watts) (Aircooled, watercooled, glycolcooled, chilled-water-cooled models only)

 

Upflow Unit SCOP (Aircooled, watercooled, glycolcooled, chilled-water-cooled models only)

 

Cooling Capacity at 95°F (evaporatively cooled models only)

 

Electrical Input at 95°F (evaporatively cooled models only)

 

Energy Efficiency ratio (EER) at 95ºF (evaporatively cooled models only)

 

 

 

Voltage*

 

Phase*

1, 3

Heat pump water-heating packages

 

Refrigerant Type*

Ozone-depleting, non-ozone-depleting

Compressor Motor Design*

Single-speed, dual-speed, multiple-speed, variable-speed

OD Fan Motor Design*

Single-speed, dual-speed, multiple-speed, variable-speed

Model number includes all components?

True, False

Is the model designed for space cooling?

True, False

Cooling Capacity (BTU per hour) if applicable

 

Cooling power input (watts) if applicable

 

Energy Efficiency Ratio (EER) if applicable

 

Integrated part load value (IPLV)

 

Heating Capacity (BTU per hour) at 47º

 

Heating power input (watts) at 47º

 

Coefficient of Performance (COP) at 47º

 

Heating Capacity (BTU per hour) at 17º

 

Heating power input (watts) at 17º

 

Coefficient of Performance (COP) at 17º

 

Heating Capacity (BTU per hour) of heat reclaim2

 

COPR of heat reclaim2

 

 

 

 

 

 

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

 

Table X-D
Portable Air Conditioners, Evaporative Coolers, Ceiling Fans, Ceiling Fan Light Kits
Whole House Fans, Residential Exhaust Fans, Dehumidifiers, Residential Furnace Fans
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Single-Duct and Dual-Duct Portable Air Conditioners

*Duct configuration

Single-duct, dual-duct, ability to operate in both single-duct and dual-duct configurations

Heating function available

True, False

Dehumidification mode available

True, False

Primary condensate removal feature

Auto-evaporation, gravity drain, removable internal collection bucket, condensate pump

Single-Duct Portable Air Conditioners

Combined Energy Efficiency Ratio (CEER) (Btu/Wh)

 

Seasonally Adjusted Cooling Capacity (SAAC) (Btu/h

 

Adjusted Cooling Capacity at 83⁰F conditions (Btu/h

 

Adjusted Cooling Capacity at 95⁰F conditions (Btu/h

 

Annual energy consumption in off-cycle mode (kWh/year)

 

Annual energy consumption in inactive or off mode (kWh/year)

 

Annual energy consumption in cooling mode (kWh/year)

 

 

 

Dual-Duct Portable Air Conditioners

Combined Energy Efficiency Ratio (CEER) (Btu/Wh)

 

Seasonally Adjusted Cooling Capacity (SAAC) (Btu/h

 

Adjusted Cooling Capacity at 83⁰F conditions (Btu/h

 

Adjusted Cooling Capacity at 95⁰F conditions (Btu/h

 

Annual energy consumption in off-cycle mode (kWh/year)

 

Annual energy consumption in inactive or off mode (kWh/year)

 

Annual energy consumption in cooling mode at 83⁰F conditions (kWh/year)

 

Annual energy consumption in cooling mode at 95⁰F conditions kWh/year)

 

Spot Air Conditioners

 

*Type

Single package, aircooled; single package, evaporativelycooled; split system: aircooled condensing unit, coil with blower; split system: evaporativelycooled condensing unit, coil alone; single package, aircooled (FD); single package, evaporativelycooled (FD); split system: aircooled condensing unit, coil with blower (FD); split system: evaporatively cooled condensing unit, coil alone (FD)

Cooling Capacity

 

Total Electrical Input

 

Cooling Efficiency Ratio (

CER)

 

 

Fan Electrical Input

 

Refrigerant Type

Ozonedepleting, nonozonedepleting

Evaporative Coolers

 

 

*Type

Direct, indirect, indirect/direct

Evaporative Media Saturation Effectiveness (%) (for direct evaporative coolers only)

 

Media Type (for direct evaporative coolers only)

Expanded paper, woven plastic, aspen wood, rigid cellulose, other (specify).

Cooling Effectiveness (for indirect evaporative coolers only)

 

Total Power (watts)

 

Airflow Rate (CFM)

 

Ceiling Fans

 

 

*Ceiling fan type (required for models manufactured on or after January 21, 2020 only)

High-speed small-diameter (HSSD), hugger, large diameter, standard, very small-diameter (VSD)

CFM (low, medium, high)

 

Watts (low, medium, high)

 

Efficacy (low, high) [CFM/watt] (required for models manufactured before January 21, 2020 only)

 

Efficacy [CFM/watt] (required for models manufactured on or after January 21, 2020 only)

 

Fan speed controls separate from light controls

True, false

Adjustable Speed Controls

(Specify) speed, variable

Reversible Fan Action Capable

Yes, no, Exception [See Section 1605.1(d)(1)(A)(3) of this Article]

Light Source Type

Compact fluorescent, incandescent, other (specify), None

Ceiling Fan Light Kits manufactured before January 21, 2020

 

Socket Type

Medium screw base, pinbased; other (specify)

Packaged with all appropriate lamps to fill all sockets

True, False

Screw-based Lamps Requirement (screw-base only)

1605.1(d)(2)(A)(1) of this Article (specify)

Meet 1605.1(d)(2)(B) (pin-based sockets only)

True, False

Operate with lamps totaling more than 190 watts (other socket types only)

True, False

Ceiling Fan Light Kits manufactured on or after January 21, 2020

 

Socket Type

Medium screw base, pinbased; other (specify)

Packaged with all appropriate lamps to fill all sockets

True, False

Lumens for each basic model of lamp or each basic model of integrated SSL (lm)

 

Rated wattage (watts)

 

Efficacy (lm/W)

 

Medium screw base sockets packaged with compact fluorescent lamps

True, False

Pin-based sockets for fluorescent lamps

True, False

Uses an electronic ballast (Pin-based sockets for fluorescent lamps only)

True, False

Whole House Fans and Residential Exhaust Fans

 

*Residential Exhaust Fan Type

Inline singleport, Inline multiport, Range hood, Bathroom and utility room

*WholeHouse Fan Type

Beltdrive singlefan, Beltdrive dualfan, Directdrive singlefan, Directdrive dual fan

Fan Motor Power (watts)

 

Air Flow (CFM)

 

Air Flow Efficiency (CFM/watt)

 

Dehumidifiers

 

Dehumidifier Type

Portable dehumidifiers with a capacity less than or equal to 25 pints per day, Portable dehumidifiers with a capacity greater than 25 pints per day and less than or equal to 50 pints per day, Portable dehumidifiers with a capacity greater than 50 pints per day, Whole-home dehumidifiers with a product case volume less than or equal to 8 cubic feet, Whole-home dehumidifiers with a product case volume greater than 8 cubic feet

Water Capacity (pints per day)

 

Case Volume

 

Integrated Energy Factor (Liters/Kilowatt Hour)

 

Residential Furnace Fans

 

Furnace Fan Types

Non-weatherized, non-condensing gas (NWG-NC); Non-weatherized, condensing gas (NWG-C); Weatherized non-condensing gas (WG-NC); Weatherized condensing gas (MH-NWG-C);Non-weatherized, non-condensing oil (NWO-NC); Non-weatherized electric furnace/ modular blower fan (NWEF/NWMB); Mobile home non-weatherized, non-condensing gas (MH-NWG-NC); Mobile home non-weatherized, condensing gas (MH-NWG-C); Mobile home electric furnace/modular blower fan (MH-EF/MB); Mobile home non-weatherized oil (MG-NOW); Mobile home weatherized gas

Wattage

 

Airflow at the maximum airflow-control setting (in cfm) (QMax)

 

Fan Energy Rating (FER)

 

 

 

 

Commercial and Industrial Fans and Blowers manufactured after November 16, 2023

Fan type

Centrifugal housed, centrifugal inline, centrifugal unhoused, centrifugal PRV supply, centrifugal PRV exhaust, axial inline, axial PRV, inline mixed-flow, power roof/wall ventilators, axial panel, radial housed

Fan impeller diameter (in.)

 

Type of Motor (if fans sold with a motor)

None, Single-phase induction, Polyphase induction, Synchronous DC (including ECM), Permanent magnet AC, or Other

Motor nameplate horsepower (if fan sold with an induction motor) (hp)

 

Pressure type

S = Static pressure

T = Total pressure

Transmission type (if fan is sold with a transmission)

Direct, V-belt, synchronous-belt, flexible coupling, none

Type of Controller (if fan sold with controller)

None, Variable frequency drive, or Other

Maximum fan speed (RPM)

 

Airflow at maximum fan speed (CFM)

 

Pressure at maximum fan speed (inches water gauge)

 

FEPact at maximum fan speed (kW

 

FEPref at maximum fan speed (kW)

 

Maximum pressure (inches water gauge)

 

Airflow at maximum pressure (CFM)

 

Fan speed at maximum pressure (RPM)

 

FEPact at maximum pressure (kW)

 

Maximum air flow (CFM)

 

Pressure at maximum airflow (inches water gauge)

 

Fan speed at maximum airflow (RPM)

 

FEPact at maximum airflow (kW)

 

FEPref at maximum airflow (kW)

 

Is the model a Series tested fan?

Yes, No

Associated Series Tested Fan Model Number (if not a series tested fan

Fan product line and model, (Field is N/A if it is a Series tested fan)

Method used to determine FEPact of test method in section 1604(d)(2), (ANSI/AMCA Standard 214-21

Section 6.1, 6.2, 6.3, 6.4, or 6.5 of the test method in section 1604(d)(2), (ANSI/AMCA Standard 214-21)

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-E
Gas and Oil Space Heaters and Electric Residential Boilers
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

All Space Heaters

 

*Energy Source

Natural gas, LPG, oil, combination (natural gas and oil), electricity

*Burner Type

Induced draft, luminous, injection type, power, pressure

Constant burning pilot light, (for gas or oil models only)

True, False

*Labeled for Outdoor Installation

True, False

*Electrical Phase

1, 3, none

Draft Equipment1, 2

Draft hood, draft diverter, barometric regulator, none

OffCycle Devices

Stack damper, electromechanical inlet damper, electromechanical flue damper, none

Flue Gas

Condensing, noncondensing

Control

 

Singlestage, twostage modulating, step modulating

Fan Motor Design (furnaces only)1, 2

Singlespeed, dualspeed, multiplespeed, variable speed

Total Nominal Fan Motor Horsepower (furnaces only)

 

Fan Motor Type (furnaces only)

Premium, standard

Fan Motor Power Factor (furnaces with variablespeed motors only)1, 2

 

Pump Motor Design (boilers only).
Note: This information is not required for boilers that are not provided with a pump.

Singlespeed, dualspeed, multiplespeed, variable speed

Total Nominal Pump Motor Horsepower (boilers only).
Note: This information is not required for boilers that are not provided with a pump.

 

Pump Motor Type (boilers only)
Note: This information is not required for boilers that are not provided with a pump.

Premium, standard

Pump Motor Power Factor (boilers with variablespeed motors only)1, 2

 

Nameplate Input Rating

 

Rated Output

 

Central Furnaces

 

 

*Mobile Home

True, False

*Air Flow Direction

Up, down, horizontal

Weatherized (required for non-mobilehome furnaces manufactured on or after November 19, 2015 only)

True, False

Fan Blower Capacity, High, at 0.5” W.C.1, 2

 

Fan Blower Capacity, Low, at 0.5” W.C.1, 2

 

Thermal Efficiency (for models ≥ 225,000 Btu/hour input and for threephase equipment < 225,000 Btu/hour input for which the manufacturer chooses to test using r sections 431.75 and 431.76)

 

Standby Watts [controls, not fan energy] (for models ≥ 225,000 Btu/hour input only)1, 2

 

Annual Fuel Energy Consumption (for models < 225,000 Btu/hour input only, except for threephase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76)

 

Annual Fuel Utilization Efficiency [AFUE] (for models < 225,000 Btu/hour input only, except for threephase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76)

 

Annual Auxiliary Electrical Energy Consumption (for models < 225,000 Btu/hour input only, except for threephase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76)

 

Thermal Efficiency at Minimum Capacity Provided and Allowed by the Controls (for models ≥ 225,000 Btu/hour input only)1, 2

 

Maximum Standby Mode Electrical Power Consumption (Watts) (applies to models manufactured on or after May 1, 2013 only)1, 2

 

Maximum Off Mode Electrical Power Consumption (Watts) (applies to models manufactured on or after May 1, 2013 only) 1, 2

 

Room Heaters, Floor Furnaces, and Wall Furnaces

 

*Type

Room heater (vented fan); room heater (gravity); floor furnace (fan); floor furnace (gravity); wall furnace (direct vent fan); wall furnace (direct vent gravity); wall furnace (vented fan); wall furnace (vented gravity)

Annual Fuel Utilization Efficiency (AFUE)

 

 

Auxiliary Electric Power (for fantype heaters only)

 

Average Annual Auxiliary Electrical Energy Consumption (for fantype heaters only)1

 

Duct Furnaces and Unit Heaters

 

*Type

Duct furnace; low static unit heater; high static unit heater; floormounted unit heater

Thermal Efficiency at Maximum Rated Capacity (mandatory for duct furnaces, voluntary for unit heaters only)

 

Energy Consumption During Standby (mandatory for duct furnaces, voluntary for unit heaters only)

 

Thermal Efficiency at Minimum Rated Capacity (mandatory for duct furnaces, voluntary for unit heaters only)

 

PowerVenting

True, False

Automatic Flue Damper

 

True, False

Infrared Gas Space Heaters

 

 

*Type

Patio heater, nonpatio heater

Intensity

High, low

Radiant Tube Type

True, False

Portable

True, False

Vented

True, False

Physically Possible to Measure Radiant Coefficient

True, False

Combustion Efficiency (for models using ANSI test method only)

 

Radiant Coefficient (for models using ANSI test method only; for models for which it is physically possible to measure radiant coefficient only)

 

Effective Heating Area (for patio heaters only)

 

Efficiency Index (for patio only)

 

Combination SpaceHeating and Water Heating Equipment

 

*Primary Function

Primary function is space heating, secondary function is domestic water heating; primary function is domestic water heating, secondary function is space heating

Volume (measured)

 

Volume (rated)

 

Energy Factor (for those models whose primary function is water heating)

 

Effective SpaceHeating Efficiency (CAAFUE) (for those models whose primary function is water heating)

 

Annual Fuel Utilization Efficiency (AFUE) (for those models whose primary function is space heating)

 

Effective WaterHeating Efficiency (CAEF) (for those models whose primary function is space heating)

 

 Combined Annual Efficiency (CAE)

 

Boilers

 

*Type

Steam, hot water

Natural Draft (for gasfired steam models manufactured on or after March 2, 2012 and ≥ 300,000 Btu/hour input only)

True, False

Design

Copper, cast iron, other

Automatic means for adjusting water temperature (small hot water boilers only)

True, False

Input at Minimum Capacity1

 

Output at Minimum Capacity1

 

Combustion Efficiency (for models ≥ 300,000 Btu/hour input only)

 

Thermal Efficiency (for models ≥ 300,000 Btu/hour input and < 2,500,000 Btu/hour input only)

 

Thermal Efficiency (for models ≥ 2,500,000 Btu/hour input only)1

 

Standby Loss (for packaged boilers ≥ 300,000 Btu/hour input only)1

 

Standby Loss (for nonpackaged boilers ≥ 300,000 Btu/hour input only) 2

 

Thermal Efficiency at Minimum Capacity Rating (for non packaged boilers ≥ 300,000 Btu/hour input only)

 

AFUE (for models < 300,000 Btu/hour input only)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-F
Water Heaters
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

All Water Heaters

 

*Energy Source

Natural gas, LPG, oil, electric resistance, heat pump

Rated Volume (except booster heaters, hot water dispensers, and large instantaneous water heaters < 10 gallons capacity)

 

Measured Volume (water heaters regulated under 10 C.F.R. section 431 subpart G as of January 1, 2017 only)

 

Input Rating

 

Heat Traps (for storage models only)

True, False

Ozone Depleting Substance in Insulation1, 2

True, False

Ozone Depleting Substance in Refrigerant (for heat pump water heaters only) 1, 2

True, False

Constant burning pilot light (for large gas and oil models only)

True, False

Mobile Home

True, False

Water Heaters Regulated Under 10 C.F.R. section 430.32

 

Water Heater Type

Gas-fired storage, oil-fired storage, electric storage, tabletop, instantaneous gas-fired, instantaneous electric, grid-enabled

First Hour Rating (for storage models only)

 

Maximum Gallons Per Minute (for instantaneous models only)

 

Recovery Efficiency

 

 

Annual Electrical Energy Consumption

 

Annual Fossil Fuel Energy Consumption (fossil fuel-fired models only)

 

Draw Pattern

Very small, low, medium, high

Uniform Energy Factor

 

 

Pilot Light Energy Consumption (for gas instantaneous models only)

 

Water Heaters Regulated Under 10 C.F.R. section 431.110
(EXCEPT residential-duty commercial water heaters)

 

Water Heater Type

Electric storage, gas-fired storage, oil-fired storage,  gas-fired instantaneous, gas-fired instantaneous

Thermal Efficiency

 

Standby Loss, %/hr. (electric models only) except for those models > 140 gallons for which exemption from standby loss standard is claimed)
Note: this data requirement is mandatory for all models except instantaneous models in which the data requirement is voluntary

 

Standby Loss Btu/hr. (fossil fuel fired models only) except for those models > 140 gallons for which exemption from standby loss standard is claimed)
Note: this data requirement is mandatory for all models except instantaneous models in which the data requirement is voluntary

 

Electrical Power During Recovery While Appliance is Heating (for storage models only)

 

Electrical Power During Standby

 

R-value of Insulation (for models > 140 gallons only) for which exemption from standby loss is claimed

 

Flue Damper (for models > 140 gallons only)

True, False

Fan Assisted Combustion (for models > 140 gallons only)

True, False

Hot Water Supply Boiler (for instantaneous models with input ≥ 300,00 Btu/hour and ≤ 12,500,000 Btu/hour only)

True, False

Residential Duty Commercial Water Heaters

Water Heater Type

Gas-fired storage, oil-fired storage electric instantaneous

Volume

 

Input

 

Draw Pattern

Very small, low, medium, high

Uniform Energy Factor

 

* “Identifier” information as described in Section 1602(a).
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X G
Pool Heaters, Portable Electric Spas, Residential Pool Pump and
 
Motor Combinations, and Replacement Residential Pool Pump Motors
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Heat Pump Pool Heaters

 

Heating Capacity at Standard Temperature Rating

 

ReadilyAccessible onoff Switch

True, False

Coefficient of Performance at Standard Temperature Rating

 

Heating Capacity at Low Temperature Rating

 

Coefficient of Performance at Low Temperature Rating

 

Average Coefficient of Performance (COP) at Standard Temperature Rating and Low Temperature Rating

 

Refrigerant Type1, 2

Ozonedepleting, nonozone depleting

Other Pool Heaters

 

Energy Source

Natural gas, LPG, oil, electric resistance

Constant Burning Pilot Light (for gas models)

True, False

Input

 

 

Thermal Efficiency

 

 

Pumps (data collection required for models manufactured on or after January 27, 2020 only)

 

Equipment Class

 

Total Pump Head in feet at BEP

 

Total Pump Head in feet at nominal speed

 

Volume per unit time (flow rate) in gallons per minute (gpm) at BEP

 

Volume per unit time (flow rate) in gallons per minute (gpm) at nominal speed

 

Nominal speed of rotation (rpm)

 

Calculated driver power input at each load point i (Pini) corrected to nominal speed, in horsepower (hp)3

 

Driver power input at each load point i (Pini), corrected to nominal speed, in horsepower, (hp)4

 

Driver power input (measured as the input power to the driver and controls)at each load point i (Pini), corrected to nominal speed, in horsepower, (hp)5

 

Full impeller diameter in inches

 

PEICL calculated or tested4

 

PEIVL calculated or tested5

 

Number of stages tested RSV and ST pumps only

 

Pump efficiency at BEP in in percent (%)1,3,4

 

Pump efficiency at BEP in PERCL1,3,4

 

Pump efficiency at BEP in percent (%)1,5

 

Pump efficiency at BEP in PERVL1,5

 

Pump configuration

 

Nominal motor efficiency in percent (%)4,5,6

 

Motor horsepower (hp) for the motor with which the pump is being rated4,5,6

 

Bowl diameter in inches (ST pumps only)3,4,5

 

PEICL

 

PEIVL

 

C-value

 

Residential Pool Pump and Motor Combinations and
Replacement Residential Pool Pump Motors
manufactured before July 19, 2021

 

Motor Construction is Split-Phase

True, False

Motor Construction is Capacitor Start-Induction Run

True, False

Motor Design

Singlespeed, dualspeed, multispeed, variablespeed

Motor has Capability of Operating at Two or More Speeds with the Low Speed having a Rotation Rate that is No More than OneHalf of the Motor’s Maximum Rotation Rate

True, False

Unit Type

Residential Pool Pump and Motor Combination,
Replacement Residential Pool Pump Motor

Pool Pump Motor Capacity

 

 

Motor Service Factor

 

Nameplate Horsepower

 

Pump Control Speed (compliance with Section 1605.3(g)(5)(B)(2) of this Article)

True, False

 

 

 

Dedicated-Purpose Pool Pumps manufactured on or after July 19, 2021

Dedicated-purpose pool pump product group

Self-priming pool filter pumps with rated hydraulic horsepower of 0.711 hp <= hhp < 2.5 hp. Self-priming pool filter pumps with rated hydraulic horsepower of hhp <0.711 hp. Non-self-priming pool filter pumps. Pressure cleaner booster pumps. Integral cartridge-filter pool pumps. Integral sand-filter pool pumps. Waterfall pumps

Freeze Protection Controls when Shipped

Enabled, Disabled, Not applicable

Default Dry-Bulb Air Temperature setting (in degrees F) (when “Freeze Protection Controls when Shipped” = Enabled)

 

Default Run-Time Setting (in minutes) (when “Freeze Protection Controls when Shipped” = Enabled)

 

Default Motor Speed (in rpm) (when Freeze Protection Controls when “Freeze Protection Controls when Shipped” = Enabled)

 

Default Motor Speed is More than ½ of the Maximum Available Speed (when Freeze Protection Controls when “Freeze Protection Controls when Shipped” = Enabled)

 

 

 

 

Self-Priming Pool Filter pumps, Non-Self-Priming Pool Filter Pumps, Pressure Cleaner Booster pumps or Waterfall Pumps

Weighted Energy Factor (WEF) in kilogallons per kilowatt-hour (kgal/kWh)

 

Rated Hydraulic Horsepower in horsepower (hp)

 

Speed Configuration for which the pump is being rated

Single-speed, Two-speed, Multi speed, or Variable-speed

True Power Factor at High Load Point

 

Dedicated-Purpose Pool Pump Nominal Motor Horsepower

 

Dedicated-Purpose Pool Pump Motor Total Horsepower

 

 

Dedicated-Purpose Pool Pump Service Factor

 

 

Input Power at the High Flow Load Point (watts)

 

Flow Rate at the High Flow Load Point (gpm)

 

Speed at the High Flow Load Point (rpm)

 

 

 

 

Self-priming pool filter pumps, Non-self-priming pool filter pumps or Pressure cleaner booster pumps

Input Power at Maximum Rotating Speed (watts)

 

Flow Rate at Maximum Rotating Speed (gpm)

 

Speed at Maximum Rotating Speed (rpm)

 

True Power Factor at Low Load Point

 

Pump Certified with NSF/ANSI 50-2015

True, False

Vertical Lift (in feet) (when “Pump Certified with NSF/ANSI 50-2015” = False)

 

True Priming Time (in minutes) (when “Pump Certified with NSF/ANSI 50-2015” = False)

 

Input Power at the Low Flow Load Point (watts)

 

Flow Rate at the Low Flow Load Point (gpm)

 

Speed at the Low Flow Load Point (rpm)

 

Self-priming pool filter pumps or Non-self-priming pool filter pumps

True Power Factor at Low Load Point

 

Pump Certified with NSF/ANSI 50-2015

True, False

Vertical Lift (in feet) (when “Pump Certified with NSF/ANSI 50-2015” = False)

 

True Priming Time (in minutes) (when “Pump Certified with NSF/ANSI 50-2015” = False)

 

Input Power at the Low Flow Load Point (watts)

 

Flow Rate at the Low Flow Load Point (gpm)

Speed at the Low Flow Load Point (rpm)

 

 

 

 

Self-priming pool filter pumps, Non-self-priming pool filter pumps, or Waterfall Pumps

Maximum Head (in feet)

 

 

 

 

Integral cartridge-filter pool pumps or Integral sand-filter pool pumps

Pool pump control is either integral to the pump or a separate component that is sold or offered for sale with the pump.

True, False

Maximum Run-Time (in hours) of the Pool Pump Control

 

 

 

 

Replacement Dedicated-Purpose Pool Pump Motors manufactured on or after July 19, 2021

Replacement Dedicated-Purpose Pool Pump Motor is a Variable-speed replacement dedicated-purpose pool pump motor

True, False

Dedicated-purpose pool pump motor total horsepower (hp)

 

Nominal efficiency at full-load and maximum operating speed (%)

 

Motor speed at full-load and maximum operating speed (rpm)

 

Motor torque at full-load and maximum operating  speed (lb-ft)

 

Input power at full-load and maximum operating speed (watts)

 

Power factor at full-load and maximum operating speed (%)

 

Motor phase

Single-phase, polyphase

Sold with motor drive

True, False

Meets requirements of 1605.3(g)(6)(D) (when “Sold with motor drive” = True)

True, False

Freeze protection controls is shipped enabled

Enabled, Disabled, Not applicable

Default dry bulb air temperature setting (“Freeze protection controls are shipped enabled”)

 

Default motor speed (rpm) (when “Freeze protection controls are shipped enabled”)

 

Default run time (minutes) (when “Freeze protection controls are shipped enabled”)

 

Is the default motor speed more than 1/2 of the maximum available speed? (when “Freeze protection controls are shipped enabled”)

True, False

 

 

 

Portable Electric Spas

*Spa type

Combination Spa, Exercise Spa, Inflatable Spa, Standard Spa

*Tested Spa Cover Model Number

 

Tested Spa Cover Manufacturer

 

Rated Capacity (number of people)

 

Rated Voltage (volts)

 

Tested Spa Cover Is Insulated

True, False

Spa Enclosure is Fully Insulated

True, False

Spa includes a skimmer

True, False

Maximum water Temperature setting is less than 1000 (for exercise spas and the exercise spa portion of combination spas only)

True, False

Portable Electric Spa Rated Volume (gallons)  (for standard spas, inflatable spas, and the standard spa portion of combination spas only)

 

Exercise Spa Rated Volume (gallons)  (for exercise spas, and the exercise spa portion of combination spas only)

 

Portable Electric Spa Fill Volume (gallons) for standard spas, inflatable spas, and the standard spa portion of combination spas only)

 

Exercise Spa Fill Volume (gallons) (for exercise spas, and the exercise spa portion of combination spas only)

 

Portable Electric Spa Normalized Standby Power (Watts) (for standard spas, inflatable spas, and the standard spa portion of combination spas only)

 

Exercise Spa Normalized Standby Power (Watts) (for exercise spas, and the exercise spa portion of combination spas only)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances

Table X H
Plumbing Fittings
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Plumbing Fittings

 

 

*Type

Showerhead, lavatory faucet (independent or collective), public lavatory faucet, kitchen faucet, metering faucet (independent or collective), lavatory replacement aerator, kitchen replacement aerator, wash fountain, lifttype tub spout diverter, turntype tub spout diverter, pulltype tub spout diverter, pushtype tub spout diverter

Flow Rate

 

 

Pulsating (for showerheads only)

True, False

Minimum Flow rate at 45 psi and 80 psi (for showerheads manufactured on or after July 1, 2016

 

Minimum Flow rate at 20 psi (for showerheads manufactured on or after July 1, 2016

 

Rim Space (for wash fountains only)

 

Tub Spout Leakage Rate When New

 

Tub Spout Leakage Rate After 15,000 Cycles

 

Commercial Prerinse Spray Valves

 

 

Product Class (required for models manufactured on or after January 28, 2019)

Product Class 1, Product Class 2, Product Class 3

Flow Rate (gpm)

 

Spray force (ounce-force (ozf))

 

 

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federallyregulated appliances
2 = Voluntary for stateregulated appliances

Table X I
Plumbing Fixtures
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Plumbing Fixtures

 

 

*Type

Blowout water closet, gravity tank type water closet, dualflush water closet, electromechanical hydraulic water closet, flushometer tank water closet, prisontype urinal, prisontype water closet, flushometer valve water closet, trough type urinal, wallmounted urinal, waterless urinal, other type urinal, vacuum type water closet

Water Consumption (dualflush effective flush volume for dualflush water closet)

 

Passes waste extraction test

True False

Waste extraction value

grams

Trough Length (troughtype urinals only)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X J
Fluorescent Lamp Ballasts and Deep Dimming Lamp Ballasts
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Fluorescent Lamp Ballasts

 

 

*Ballast Input Voltage

120, 277, between 120 and 277 other (specify)

*Number of Lamps

 

*Type of Fluorescent Lamp

F34T12, F96T12/ES, F96T12HO/ES (2-foot U-shaped, 4-foot medium bipin, 4-foot miniature bipin high output, 4-foot miniature bipin standard output, 8-foot high output, 8-foot slimline

Product Class (from U.S. DOE CCMS product template

 

Designed for Dimming to 50% or Less of Maximum Output

True False

Power Factor

 

 

*Building Application

Commercial, designed (not classified as sign ballasts) to operate 8-foot high output lamps, designed and labeled as sign ballasts to operate 8-foot high output lamps, residential; not classified as residential, other

Sign Ballasts

True False

Input Power Watts

 

Ballast Luminous Efficiency

 

 

Circuit Design

Cathode cutout, electronic, magnetic

*Start

Instant, programmed rapid

Ballast Frequency

High frequency, low frequency, other

Average Total Lamp Arc Power

 

 

Deep-Dimming Fluorescent Lamp Ballasts

 

*Ballast Input Voltage

120, 277, other (specify)

*Number of Lamps

 

*Lamp Type

T5, T8, other (specify)

*Dimming Type

Continuous, stepped, individual lamp control, other (specify)

*Control Type

3-wire, 0-10 volts, digital communication, phase, other (specify)

*Start Type

Instant start, rapid start, program start, other (specify)

P100

 

Arc Power 100

 

P80

 

Arc Power 80

 

P50

 

Arc Power 50

 

BLE 100

 

BLE 80

 

BLE 50

 

 

P0 (standby mode power)

 

Weighted Ballast Luminous efficacy

 

 

Power Factor

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X K
Lamps
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Federallyregulated general service

fluorescent lamps

 

 

*Type

4foot medium bipin general service fluorescent lamp, 2foot Ushaped general service fluorescent lamp, 8foot slim line general service fluorescent lamp, 8foot high output general service fluorescent lamp, 4foot miniature bipin standard output general service fluorescent lamp, 4foot miniature bi pin high output general service fluorescent lamp

Rated Color Rendering Index

 

Correlated Color Temperature (for lamps manufactured on or after July 15, 2012)

 

Minimum Average Lamp Efficacy (LPW)

 

Federally regulated incandescent reflector lamps sold before January 1, 2020

Minimum Average Lamp Efficacy

 

Federally regulated Medium Screw Base Compact Fluorescent Lamps sold before January 1, 2020

 

Lamp Power (Watts)

 

Minimum Efficacy (LPW)

 

Lamp Configuration

Bare or Covered (no reflector)

1,000 Hour Lumen Maintenance

True False

Lumen Maintenance Requirements

True False

Rapid Cycle Stress Test

True False

Average Rated Lamp Life

True False

Federally regulated Medium Screw Base General Service Incandescent and OLED Lamps sold before January 1, 2020

 

Type

General Service Incandescent, LED, OLED

Voltage Range

 

 

Rated Lumen Range

 

Maximum Rate Wattage

 

Minimum Rate Lifetime

 

Color Rendering Index

 

Minimum Efficacy (LPW) (required on or after January 1, 2018)

 

Modified Spectrum

 

True False

Bulb Finish (incandescent only)

Clear, frost, soft white

ANSIdesignated Bulb Shape

A15, A19, A21, A23, A25, PS25, PS30, BT14.5, BT15, CP19, TB19, CA22

Federally regulated Candelabra Base and Intermediate Base Incandescent Lamps sold before January 1, 2020

Base Type

Candelabra, intermediate

Maximum Rated Wattage

 

Federally regulated Medium Screw Base Modified Spectrum General Service Incandescent Lamps sold before January 1, 2020

Type

 

Rated Voltage

 

 

Rated Lumen Range

 

Maximum Rate Wattage

 

Minimum Rate Lifetime

 

Color Rendering Index

 

State-regulated small diameter

directional lamps

 

Base Type

Lamp Type (examples PAR16, MR11, MR16, R)

 

Lamp Power (Watts)

 

Lamp Output (Lumens)

 

Beam Angle

 

 

Center Beam Candle Power (CBCP)

 

Efficacy (Lumens per Watt)

 

Color Rendering Index (CRI)

 

 

Combined CRI + Efficacy (only applies where efficacy < 80 LPW)

 

Correlated Color Temperature

 

Rated Lifetime Test Completed

 

Estimated rated Lifetime (hours) (when “Rated Lifetime Test Completed = False

True False

Rated Lifetime (hours) (when “Rated Lifetime Test Completed = True)

 

State-regulated

Light Emitting Diode (LED) lamps

 

Base Type

Lamp Shape

E12, E17, E26, GU-24, retrofit kit

Dimmable

A, B, BA, C. CA. F. G. other

Minimum Dimming level (%) (if Dimmable = True)

True, False

Reduced Flicker Operation (if Dimmable = True)

True, False

Correlated Color Temperature

 

Duv

 

 

Rated Lifetime Test Complete

 

Estimated rated Lifetime (hours) (when “Rated Lifetime Test Completed = False

 

Rated Lifetime (hours) (when “Rated Lifetime Test Completed = True)

Ambient, Elevated

Lifetime test environment temperature

 

Lamp Power (Watts)

 

Lumen Output (Lumens)

 

Efficacy (Lumens per Watt)

 

Color Rendering Index (Ra)

 

Compliance Score

 

Power Factor

 

 

Standby Power (Watts (if applicable)

 

Connected network type (if applicable)

Wi-Fi, ZigBee, ANT, Bluetooth, RF, Wired, Other

R1

 

R2

 

R3

 

R4

 

R5

 

R6

 

R7

 

R8

 

R92

 

Meets applicable luminous intensity distribution requirements

 

Audible Noise at 100% output (decibels)

 

Audible Noise at 20% output (decibels)

 

Start Time2

 

6000 hour lumen maintenance2

 

6000 hour survival rate2

 

Projected time to L702

 

Dimming Control Compatibility (when “Dimmable” = True)

Forward, Phase cut control, reverse phase cut, powerline carrier, digital, 010 VDC, other

NEMA SSL 7A Compatible 2 (If compatible with forward phase cut dimmer control answer “True,” If not answer “False.”)

True, False

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X L
Emergency Lighting
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Emergency Lighting

 

Light Source Type

LED, electroluminescent, fluorescent, incandescent, other (specify)

Battery Backup

 

True, False

Number of Faces

 

Sign Format

Edgelit, panel, matrix, stencil, other (specify)

Input Power Demand

 

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliance

Table X-M
Traffic Signal Modules
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Traffic Signal Modules for Vehicle control

 

Module Color

Green, amber, red

Module Type

Circular, arrow, lane controlarrow, lane controlX, pedestrian, other (specify)

Modular Size (circular, arrow only)

 

Nominal Wattage at 25° C

 

Maximum Wattage at 74° C

 

Traffic Signal Modules for Pedestrian Control

 

Module Type

Hand, Walking Person, walk, don’t walk, countdown (Specify)

Power Consumption at 25° C

 

Power Consumption at 74° C

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X- N
Luminaires and Torchieres
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Torchieres

 

 

*Lamp Type of UpwardFacing Lamp(s)

Screwbased Incandescent, Halogen, Fluorescent Pinbased, Other (specify)

*Lamp Type of Side Lamp(s)

Screwbased Incandescent, Halogen, Fluorescent Pinbased, Other, None (specify)

Total Number of Lamp Sockets

 

Maximum Possible Power Demand, All Sockets (watts)

 

Method of Insuring 190 Watt Maximum Power Consumption

Currentlimiting Device, Thermal Switch, Other (specify)

Metal Halide Luminaires

 

*Lamp Position (orientation)

Vertical BaseUp, Vertical Base Down, Horizontal, Universal, Other (specify)

Lamp Rating, low (watts)

 

Lamp Rating, high (watts)

 

Outdoor Luminaire

True, False

Compliance Option Used

≥ 90/92% efficient ballast,

≥ 88% efficient ballast with integral control (Occupancy Sensor),
≥ 88% efficient ballast with integral control (Automatic Daylight Control),
 ≥ 88% efficient ballast labeled for relamping with only 150160 watt, 200215 watt, 290335 watt, or 336500 watt lamps

Ballast Type [only applies to models manufactured on or after January 1, 2006]

Probestart electronic, probestart magnetic, pulsestart electronic, pulsestart magnetic, other (specify)

Minimum Ballast Efficiency (percent)

 

Lamp Exceptions2

Exception(s) met, no exceptions met

Integral Control Type (for integral control compliance method only)

Occupancy sensor, Automatic daylight control

Integral Control Method (for integral control compliance method only)

Directly into luminaire housing Packaged and sold prewired Integrated wireless radio controlled sensor

Maximum relamping rated wattage on a factoryinstalled label (watts) (for relamping wattage compliance method only)

 

Packaged with efficient lamps (for relamping wattage compliance method only)

True, False

UnderCabinet Fluorescent Fixtures (Luminaires)

 

Lamp Length (inches)

 

Number of Lamps for which Fixture (Luminaire) is Designed

 

Ballast Efficacy Factor

 

* “Identifier” information as described in Section 1602(a)
 1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-O
Dishwashers
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

* Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Dishwashers

 

 

*Type

Compact, standard

* Number of Place Settings

 

Water Heating

Dishwasher

 

True, False

Truncated Normal Cycle Capable

True, False

Soil Sensing

True, False

Maximum Energy Use

 

Maximum Water Use

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-P
Clothes Washers
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Clothes Washers that are consumer products

 

*Type

Frontloading, top loading

*Controls

Automatic, semiautomatic, other (specify)

*Axis

Horizontal, vertical

SudsSaving

 

True, False

Combination Washer/Dryer1

True, False

Clothes Container Compartment Capacity

 

Power Consumption Per Cycle1

 

Water Consumption Per Cycle

 

Integrated Modified Energy Factor

 

 

Integrated

Water Factor

 

 

Remaining Moisture Content

 

Commercial Clothes Washers

 

 

*Type

Frontloading, top loading

*Controls

Automatic, semiautomatic, other (specify)

*Axis

Horizontal, vertical

SudsSaving

True, False

Combination Washer/Dryer

True, False

Clothes Container Compartment Capacity

 

Power Consumption Per Cycle

 

Water Consumption Per Cycle

 

Modified Energy Factor

 

Water Factor (effective for models manufactured before January 1, 2018)

 

Integrated Water Factor (effective for models manufactured on or after January 1, 2018)

 

Remaining Moisture Content (required only on and after January 1, 2004)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-Q
Clothes Dryers
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Clothes Dryers

 

 

*Energy Source

Gas, electric

*Drum Capacity

 

*Voltage

120, 240, other (specify)

Combination Washer/Dryer1

True, False

Venting

Vented, ventless

Combined Energy Factor

 

Constant Burning Pilot Light (Gas models only)

True, False

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-R
Cooking Products and Food Service Equipment
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Consumer Product Cooking Products

 

*Type

Conventional range, conventional cooking top, conventional oven, microwaveonly oven, countertop convection microwave oven, builtin microwave oven, overthe range convection microwave oven, combined cooking products, other (specify)

*Energy Source

Gas, electric, microwave

Electrical Supply Cord (for gas models only)

True, False

*Constant Burning Pilot Light

True, False

Annual Cooking Energy Consumption

 

Clock Power Consumption (for gas conventional ovens only)

 

Pilot Light Consumption (for gas conventional ovens only)

 

Annual Secondary Energy Consumption (for gas conventional ovens only)

 

Average Standby Power (data required for various microwave ovens manufactured on or after June 17, 2016 only)

 

Off Mode Power1

 

On Mode Power

 

Commercial Convection Ovens

 

 

Energy Input Rate

 

Idle Energy Consumption Rate

 

Commercial Hot Food Holding Cabinets

 

 

Measured Interior Volume (ft3)

 

Energy Input Rate

 

Idle Energy Consumption Rate

 

Commercial Range Tops

 

 

Energy Input Rate

 

Cooking Energy Efficiency

 

Test Cooking Vessel Diameter

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-S
Electric Motors
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Electric Motors

 

 

Type

NEMA Design A, NEMA Design B, IEC NEMA Design C, IEC, Design H, IEC Design N, Fire pump electric motor

Voltage (V)

 

Speed1 (RPM)

 

Rated Horsepower (hp)

 

Input Power (kW)

 

Air Exchange

Open, enclosed

Number of Poles

2, 4, 6, 8

Nominal Full Load Efficiency (%)

 

State-regulated Compressors

Isentropic Efficiency

 

Equipment Class

Rotary, lubricated, air-cooled, fixed-speed compressor; Rotary, lubricated, air-cooled, variable-speed compressor; Rotary lubricated, liquid-cooled, fixed-speed compressor; Rotary, lubricated, liquid-cooled, variable-speed compressor

Full-load package isentropic efficiency (fixed-speed compressor only) or part-load package isentropic efficiency (variable-speed compressor only)

 

Full-load actual volume flow rate (CFM)

 

Compressor motor nominal horsepower (HP)

 

Full-load operating pressure (psig)

 

Maximum full-flow operating pressure (psig)

 

Pressure ratio at full-load operating pressure

 

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-T
Distribution Transformers
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Distribution Transformers

 

Distribution Transformer type (Data required for liquidimmersed and mediumvoltage drytype on or after January 1, 2010 only)

Lowvoltage drytype; liquid immersed; mediumvoltage drytype

*Phase

1, 3

kVa (BIL kVa for mediumvoltage dry type)

 

Rated Output Power

 

Total Loss Power

 

Efficiency (for mediumvoltage models, this will be the Efficiency at 2045 kV)

 

Efficiency 2 (medium voltage models only, Efficiency at 4695 kV)

 

Efficiency 3 (medium voltage models only, Efficiency at ≥ 96 kV)

 

* “Identifier” information as described in Section 1602(a).
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-V
Computers, Computer Monitors, Televisions,
Signage Displays, and Consumer Audio and Video Equipment.
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Televisions

 

Type*

CRT, Plasma, LCD, DLP, Rear Projection, Laser, OLED, LCOS

Viewable Screen Area

 

 

Screen Size

 

 

Automatic Brightness

Control

 

True, False

Automatic Brightness Control enabled

True, False

Forced Menu

 

True, False

Native Vertical Resolution

 

 

Aspect Ratio

 

 

Integrated Occupancy Sensor

 

True, False

Lhome

 

Lhigh

 

Luminance Ratio

 

TV StandbyPassive Mode Power (watts)

 

On Mode Power (watts)

 

Retail On Mode Power (watts)

 

Power Factor

 

 

Consumer Audio and Video Equipment

Compact Audio Products

 

Power Usage in Audio StandbyPassive Mode for Models Without a PermanentlyIlluminated Clock Display (watts)

Power Usage in Audio StandbyPassive Mode for Models With a PermanentlyIlluminated Clock Display (watts)

 

Digital Versatile Disc Players and Digital Versatile Disc Recorders

Power Usage in Video StandbyPassive Mode (watts)

 

Computer Monitors

 

Backlight Type

CCFI, LED, OLED, Quantum Dots

EPD

True, False

OLED

True, False

Gaming Monitor w/ Incremental Hardware

True, False

Gaming Monitor w/o Incremental Hardware

True, False

Fast refresh rate gaming monitor

 

True, False

Maximum Refresh Rate (Hz)

 

KMM_KVM

True, False

Very High Performance

True, False

Curved Monitor

True, False

Viewable Screen area (square inches)

 

Screen size (diagonal inches)

 

Automatic Brightness Control

True, False

Automatic Brightness Control Enabled when Shipped

True, False

Screen Luminance (Candelas Per Square Meter)

 

Native resolution (megapixels)

 

Power Draw in On Mode (watts)

 

Power Draw in Computer Monitor Sleep Mode (watts)

 

Power Draw in Computer Monitor Off Mode (watts)

 

Touch Screen Capability

True, False

Touch Screen Enabled in On Mode

True, False

Touch Screen Enabled in Computer Monitor Sleep Mode

True, False

Touch Screen Enabled in Computer Monitor Off Mode

True, False

Color Gamut

>32.9% OF cieluV (99% or more of defined Srgb colors),
>38.4% OF cieluV (99% or more of defined Adobe rgb colors),
<32.9% OF cieluV

Medical Computer Monitor

 

(Other than the identifier information shown under “All Appliances” (e.g., manufacturer name, brand name, model number), no other data is required for medical computer monitors at this time.)

 

Computers

(Note: Units with more than one integrated display must certify related data for each screen)

Computer Type

Desktop, Notebook, Small-Scale Server, Workstation, Thin Client, Portable All-In-One, Mobile Gaming System, Mobile Workstation, High Expandability Computer, Rack-mounted Workstation

Operating System Type

None, Limited Capability Operating System, Other

Operating System Type (Provide the operating system used during testing to calculate energy consumption.)

 

Core Speed (gigahertz)

 

Number of CPU Cores

 

CPU Support for 4 or more channels of memory or a 256 bit or greater memory interface

True, False

Number of 3.5” hard-disk drives and Others (other than main storage)

 

Number of 2.5” hard-disk drives (other than main storage)

 

Number of solid state drives (other than main storage)

 

Number of hybrid solid state drives (other than main storage)

 

Nameplate output power of the external power supply (watts) (notebook computers and mobile gaming systems only)

 

Total Battery Capacity (watt-hours) (notebook computers, portable all-in-one, and mobile gaming systems only)

 

Discrete GPU(s) present in system

True, False

First Discrete GPU is packaged on the same substrate as the CPU

True, False

First Discrete GPU Frame Buffer Bandwidth (rounded to nearest gigabyte per second)

 

Total Number of Discrete GPUs

 

Integrated display

True, False

Multi-screen notebook

 

True, False

Number of integrated screens

 

Color Gamut (if computer has integrated display)

>32.9% OF cieluV (99% or more of defined Srgb colors),
>38.4% OF cieluV (99% or more of defined Adobe rgb colors),
<32.9% OF cieluV

Diagonal screen size (inches) (if computer has integrated display)

 

Viewable screen area (square inches) (if computer has integrated display)

 

Resolution (megapixels) (if computer has integrated display)

 

Enhanced Performance (if computer has integrated display)

True, False

Length of time of user inactivity before computer entering sleep (minutes)
Do not report a number if the model does not enter sleep.

 

Length of time of user inactivity before placing display into sleep (minutes)
Do not report a number if the model does not enter sleep.

 

Notebook computer with Cyclical behavior

True, False

Operation of the notebook computer without a battery pack is a supported configuration when connected to the mains power source

True, False

One complete cycle of battery charging and discharging in computer short-idle mode (hours:minutes:seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

Computer short-idle mode test duration (hours:minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

One complete cycle of battery charging and discharging in computer long-idle mode (hours: minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

Computer long-idle mode test duration (hours: minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

One complete cycle of battery charging and discharging in computer sleep mode (hours: minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

Computer sleep mode test duration (hours: minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

One complete cycle of battery charging and discharging in computer off mode (hours: minutes: seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

Computer off mode test duration (hours: minutes :seconds) (Applies only to notebook computers with cyclical behavior where operation without a battery pack is not a supported configuration when connected to the mains power source)

 

Wired Ethernet or Fiber Card with a transmit rate of more than 1 GB/s or greater

True, False

Data transmission rate of wired Ethernet port with a transmit rate of more than 1 Gb/s and less than 10 Gb/s that is not an Add-in card

 

Energy Efficient Ethernet Capability

True, False

Total Number of Add-in Cards

 

Total Number of Video Surveillance Cards

 

Total Number of Wired Ethernet or Fiber Cards with a transmit rate of 10 GB/s or greater

 

System memory bandwidth (gigabytes/second))

 

8 gigabytes or more of system memory with a bandwidth of 632 GB/s or more

True, False

8 gigabytes or more of system memory with a bandwidth of 432 GB/s or more

True, False

4 gigabytes or more of system memory with a bandwidth of 146 GB/s or more

True, False

4 gigabytes or more of system memory with a bandwidth of 134 GB/s or more

True, False

Total Number of System Memory Channels Used

 

First channel system memory type

DDR, GDDR, HBM, Other, None

First channel system memory bandwidth (GB/s)

 

First channel system memory (GB)

 

Second channel system memory type

DDR, GDDR, HBM, Other, None

Second channel system memory bandwidth (GB/s)

 

Second channel system memory (GB)

 

Third channel system memory type

DDR, GDDR, HBM, Other, None

Third channel system memory bandwidth (GB/s)

 

Third channel system memory (GB)

 

Fourth channel system memory type

DDR, GDDR, HBM, Other, None

Fourth channel system memory bandwidth (GB/s)

 

Fourth channel system memory (GB)

 

Fifth channel system memory type

DDR, GDDR, HBM, Other, None

Fifth channel system memory bandwidth (GB/s)

 

Fifth channel system memory (GB)

 

Sixth channel system memory type

DDR, GDDR, HBM, Other, None

Sixth channel system memory bandwidth (GB/s)

 

Sixth channel system memory (GB)

 

Seventh channel system memory type

DDR, GDDR, HBM, Other, None

Seventh channel system memory bandwidth (GB/s)

 

Seventh channel system memory (GB)

 

Eighth channel system memory type

DDR, GDDR, HBM, Other, None

Eighth channel system memory bandwidth (GB/s)

 

Eighth channel system memory (GB)

 

Computer sleep mode type

ACPI S3, Other

Computer off mode power (watts)

 

Computer sleep mode power (watts)

 

Long-idle  power (watts)

 

Short-idle  power (watts)

 

Expandability Score

 

Meets full capability mode weighting criteria

True, False

Meets remote wake mode weighting criteria

True, False

Total Annual Energy Consumption (kilowatt hours per year)

 

Power Supply Meets Table V-9 or Level VI

True, False

Small Volume Manufacturer

 

True, False

Motherboard model number

 

Power supply type

Internal, External

Internal power supply size (watts)

 

Power factor at full load of the computer’s power supply that is not a federally regulated external power supply

 

Median power factor during short-idle of the computer’s power supply that is not a federally regulated external power supply

 

Power supply model number

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally
regulated appliances
2 = Voluntary for state
regulated appliances

Table X-W
Battery Charger Systems
Data Submittal Requirements

Appliance

CFDHBG Required Information

Permissible Answers

All Appliances

** Manufacturer’s Name

 

* Brand Name

 

*Model Number

 

Date model to be displayed

 

Regulatory Status

Federallyregulated consumer product, federallyregulated commercial and industrial equipment, nonfederallyregulated

Small Battery Charger Systems

 

 

*Consumer Product Model Number

End use product model number (specify)

Product Type

 

24hour charge and maintenance energy

 

Battery maintenance mode power

 

No battery mode power

 

Battery capacity of tested battery (if more than 1 charger port report the total of all battery capacities connected during test)

 

Inductive charger systems

 

True, False

Number of charger ports

 

Compatible battery chemistries

 

Battery backup or uninterruptible power supply

True, False

Á la carte charger

True, False

USB charger system

 

True, False

Location of marking or labeling

Packaging, Product

Battery Test Procedure Used

 

Consumer Product (T/F)

True, False

Large Battery Charger Systems

 

 

Product Type

 

Charge return factor 100

 

Charge return factor 80

 

Charge return factor 40

 

Power conversion efficiency

 

 

Power factor

 

 

Maintenance mode power

 

No battery mode power

 

Battery capacity of tested battery

 

Compatible battery chemistries

 

Location of marking or labeling

Packaging, Product

Federally Regulated Battery Chargers (manufactured on or after June 13, 2018)

Product Group Code

1, 2, 3, 4, 5, 6, 7

 Nameplate Battery Voltage of Test Battery in Volts (V)

 

 Nameplate Battery Charge Capacity of Test Battery in Ampere-Hours (Ah)

 

 Nameplate Battery Energy Capacity of Test Battery in Watt-Hours (Wh)

 

 Maintenance Mode Power in Watts (Pm)

 

 Standby Mode Power in Watts (Psb)

 

 Off Mode Power in Watts (Poff)

 

 Battery Discharge Energy in Watt-Hours (Ebatt)

 

 24-Hour Energy Consumption in Watt-Hours (E24)

 

 Duration of the Charge and Maintenance Mode Test in Hours (Tcd)

 

 Unit Energy Consumption (UEC) (kWh/yr)

 

 Manufacturer of Test Battery

 

 Model of Test Battery

 

 Manufacturer of External Power Supply (If Applicable)

 

 Model of External Power Supply (If Applicable)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances

 

Table X-X
Landscape Irrigation Equipment
Data Submittal Requirements

Appliance

Required Information

Permissible Answers

Spray Sprinkler Bodies

Regulation pressure (psi)

 

Maximum operating pressure (psi)

 

Percent difference between the initial calibration flow rate and the maximum flow rate at any tested pressure level, averaged for the selected samples at the test pressure levels where the maximum flow rate occurred (percent)

 

Percent difference between the initial calibration flow rate and the  flow rate at any tested pressure level, averaged across all pressure levels and all selected samples (percent)

 

Average outlet pressure at the initial calibration point of the selected samples (psi)

 

* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances

 

 

(4)   Declaration.

(A)  Each statement shall include a declaration, executed under penalty of perjury of the laws of California, that

1.   all the information provided in the statement is true, complete, accurate, and in compliance with all applicable provisions of this Article;

2.   the requirements of Section 1606(g) have been and are being complied with;

3.   for appliances for which there is an energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in Section 1605.1, 1605.2, or Section 1605.3, that the appliance complies with the applicable standards;

4.   the appliance was tested under the applicable test method specified in Section 1604, and, for the following appliances, was tested as follows:

a.    for other selfcontained commercial refrigerators, refrigeratorfreezers, and freezers with doors that are passthrough and rollthrough refrigerators and freezers, that the back (loading) doors remained closed throughout the test;

b.    for all refrigerators, refrigeratorfreezers, and freezers were tested using alternating current electricity only;

c.    for all split system central air conditioners and compressorcontaining units, these models were tested with the combination of compressor-containing and noncompressor containing units specified in 10 C.F.R. section 429.16 (b)(2);

d.    for all gasfired air conditioners and gasfired heat pumps, all appliances were tested to ANSI Z21.40.41996 as modified by CEC, Efficiency Calculation method for GasFired Heat Pumps as a New Compliance Option (1996);

e.    for evaporative coolers, all appliances were tested to the applicable test method referenced in Table D3 with the modifications appearing in Table D3;

f.     for whole house fans, all appliances were tested to HVI916, and if equipped with louvers, were tested with manufacturerprovided louvers in place;

g.    for battery charger systems for which certification is based on testing of representative battery charger system models, the models tested as representative are those known or expected to have the poorest performance characteristics such that the data generated meets the requirements of Section 1606(a)(3)(D) of this Article for all associated models; and

h.    for kitchen faucets that utilize an optional and temporary higher flow rate than 1.8 gpm, the higher flow rate has been tested utilizing the test procedure identified for kitchen faucets in section 1604(h) at 60 psi and verified to have a flow rate less than or equal 2.2 gpm.

i.     for state-regulated compressors that are rated using an alternative efficiency determination method (AEDM) in lieu of testing, that the represented value of efficiency, consumption, or other non-energy metrics for the basic model was determined through the alternative efficiency determination method specified in section 1604(s).

 

Exceptions to Section 1606(a)(4)(A)4: Section 1606(a)(4)(A)4 is not applicable to the following types of appliances that have no test methods found in section 1604 of this Article:

(1)   federally regulated organic light emitting diode (OLED) lamps,

(2)   federally regulated candelabra base incandescent lamps,

(3)   federally regulated intermediate base incandescent lamps,

(4)   traffic signal lamps,

(5)   torchieres, and

(6)   portable luminaires showing compliance with Sections 1605.3(n)(3)(A)1., 1605.3(n)(3)(A)2., or 1605.3(n)(3)(A)5. of this Article, and

(7)   self-contained lighting controls.

 

5.    all units of the appliance are marked as required by Section 1607, of this Article, and, for the following appliances, are marked as follows:

a.    for all air conditioners, heat pumps, furnaces, boilers, and water heaters that are not subject to NAECA and that comply with the October 29, 2001 provisions in Tables 6.2.1 A through G of ASHRAE/IES Standard 90.11999, they are marked, permanently and legibly on an accessible and conspicuous place on the unit, with a statement that the equipment complies with the 2001 requirements of ASHRAE Standard 90.1;

b.    for all other air conditioners, heat pumps, furnaces, boilers, and water heaters that are not subject to NAECA and that comply with the October 29, 1999 provisions (but not with the October 29, 2001 provisions) in Tables 6.2.1 A through G shall be marked, permanently and legibly on an accessible and conspicuous place on the unit, with a statement that the equipment complies with the 1999 requirements of ASHRAE Standard 90.1;

c.    for all distribution transformers, each appliance complies with the labeling requirements of “DOE Compliant” or equivalent;

d.    for all illuminated exit signs meeting the criteria of Section 1605.1(l), of this Article, each appliance is marked by the manufacturer with a block E inside a circle; the mark commonly referred to as “Circle E.” The size of the mark shall be commensurate with other markings on the sign, but not smaller than 1/4”;

e.    for all torchieres, each unit of torchieres and each package containing a torchiere is marked, permanently and legibly on an accessible and conspicuous place on the unit, in characters no less than 1/8” on the inner surface of the reflector bowl of the torchiere, and 1/4” on the packaging, “LAMPS MUST TOTAL NO MORE THAN 190 WATTSTORCHIERE IS NONCOMPLIANT IF IT IS ABLE TO DRAW MORE THAN 190 WATTS.”;

f.     for commercial prerinse spray valves, each unit is marked, permanently and legibly on an accessible and conspicuous place on the unit, in characters no less than 1/8”, the flow rate of the unit, in gallonsper minute (gpm) at 60 psi;

g.    for residential pool pumps, each pool pump is marked permanently and legibly on an accessible and conspicuous place on the unit, in characters no less than 1/4”, with the nameplate HP of the pump and, if manufactured on or after January 1, 2010, with the statement, “This pump must be installed with a two, multi, or variablespeed pump motor controller”;

h.    for residential pool pump motors, each pool pump motor is marked permanently and legibly on an accessible and conspicuous place on the unit, in characters no less than 1/4”, with the pool pump motor capacity of the motor.

i.     each replacement dedicated-purpose pool pump motor is marked in accordance with subdivision 1607(d)(16) of this Article.

(B)  If the manufacturer is a corporation, partnership, or other business entity, the declaration shall be signed by an individual authorized to make the declaration and file the statement on behalf of the business entity, and the declaration shall contain an affirmation that the individual signing is so authorized.

(C)  The declaration shall be submitted electronically through the MAEDbS and maintained by the Executive Director for a period of at least ten years, pursuant to the requirements in section 1606(j) of this Article.

 

(b)   Review of Statements by the Executive Director.

Text

Description automatically generated with medium confidence

In this subsection, “manufacturer” also includes a third party filing a statement under Section 1606(f) of this Article.

(1)  Determination. The Executive Director shall determine whether a statement is complete, accurate, and in compliance with all applicable provisions of this Article, and whether the appliance for which the statement was submitted complies with all applicable standards in Section 1605.1, 1605.2, and Section 1605.3 of this Article.

(2)   Informing Manufacturer and Third Party of Determination.

(A)  The Executive Director shall inform the manufacturer's MAEDbS-designated contact person or the third party's MAEDbS-designated contact person, as described in section 1606(f) of this Article, of the determination within 30 calendar days after receipt by the Executive Director

(B)  The Executive Director's determination shall be sent electronically through the MAEDbS to the manufacturer's MAEDbS-designated contact person..

(3)   Nature of Determination.

(A)  Statement is Incomplete. If the Executive Director determines that a statement is not complete, or that the statement does not contain enough information to determine whether it is accurate or whether the appliance complies with an applicable standard, the Executive Director shall return the statement through the MAEDbS to the manufacturer's MAEDbS-designated contact person with an explanation of its defects and a request for any necessary additional information. The manufacturer shall refile the statement through the MAEDbS with all information requested by the Executive Director. The Executive Director shall review the refiled statement according to the time limits in Section 1606(b)(2) of this Article.

(B)  Statement is Inaccurate or Appliance Does Not Comply. If the Executive Director determines that the statement is inaccurate or that the appliance does not comply with an applicable standard, the Executive Director shall reject the statement and return it through the MAEDbS to the manufacturer's MAEDbS-designated contact person with an explanation of its defects. The manufacturer may submit a revised statement through the MAEDbS for the appliance at any time.

(C)  Statement is Complete and Accurate and Appliance Complies. If the Executive Director determines that the statement is complete and accurate and that the appliance complies with all applicable standards, the Executive Director shall immediately include the appliance in the MAEDbS and shall so inform the manufacturer's MAEDbS-designated contact person. (section 1608(a) of this Article. states that no appliance within the scope of these regulations may be sold or offered for sale in California unless the appliance is in the MAEDbS.)

 

(c)   Modernized Appliance Efficiency Database System of Appliance Models.

Text

Description automatically generated with medium confidence

(1)  Creation of the MAEDbS. The Executive Director shall maintain a database known as the Modernized Appliance Efficiency database (MAEDbS). The MAEDbS shall consist of two parts:

(A)  ”Approved MAEDbS.” The Approved MAEDbS shall contain, at least, information on all appliances that are currently in production, for which complete and accurate statements have been received pursuant to section 1606(a), and that have not been removed from MAEDbS.  The Approved MAEDbS shall contain, at least, information on all appliances that are currently in production, for which complete and accurate statements have been received pursuant to Sections 1606(c)(3), Sections 1606(d)1606(e), or 1608(c)|topic=(c) All Appliances\: Submittal of Reports of Manufacturers' Certification Testing. 1608(e) of this Article.

If basic models are certified using an alternate test procedure established pursuant to Section 1603(c)(1) of this Article or for which the Executive Director has made a specification under either section 1603(c)(2)(A) or section 1603(c)(2)(B) of this Article, the Approved MAEDbS shall contain a second section which shall contain only those basic models for which certification to an applicable alternate test procedure is made.

(B) “Archived MAEDbS.” The Archived MAEDbS shall contain, at least, information on all appliances that:

1. are no longer in production, for which complete and accurate statements have been received pursuant to section 1606(a) of this Article or

2. have been removed from the Approved MAEDbS pursuant to sections 1606(e)(2) or 1608(c) of this Article.

(2) Status of the MAEDbS. The MAEDbS is the directory published by the Energy Commission within the meaning of Title 24, California Code of Regulations, part 6, Subchapter 1, Section 100(h). The MAEDbS in existence on the effective date of this paragraph is the directory referred to in this paragraph, until that existing MAEDbS is modified by the Executive Director pursuant to this Article.

(3) Confirmation of the MAEDbS Listings. The Executive Director may, by electronically writing (either via e-mail or directly through the MAEDbS) to the most recent electronic address filed pursuant to section 1606(a)(2)(B) of this Article, request each manufacturer of an appliance listed in the MAEDbS to confirm the validity, or to correct in compliance with this Article, all of the information in each of its MAEDbS listings. If within 30 calendar days of the electronic mailing there is no such reply, the appliance shall be removed from the Approved MAEDbS and moved into the Archived MAEDbS, and it may be presumed that the appliance is no longer in production.

(A) If the lack of compliance with any requirements of this Article is strictly limited to non-compliance with standards adopted since the most recent filing by the manufacturer, after initially notifying the manufacturer under the requirements found in section 1606(c)3 of this Article, all affected models will be moved from the Approved MAEDbS to the Archived MAEDbS without providing any additional electronic notice to the manufacturer. The effective date for moving such affected models to the Archived MAEDbS will be the effective date of the new standard.

 

(d)   Assessment of Completeness, Accuracy, and Compliance of Manufacturer Statements.

Text

Description automatically generated with medium confidence

(1). Notwithstanding any other provision of these regulations, the Executive Director may at any time challenge the completeness, accuracy, and compliance with the requirements of this Article, of any statement or confirmation filed pursuant to this Section. If the statement is incomplete or inaccurate, or if the Executive Director determines that the statement otherwise fails to comply with any of the requirements of this Article then he or she shall, ten working days after providing electronic notice via e-mail or directly through the MAEDbS to the person designated in section 1606(a)(2)(B) of this Article, remove the appliance from the MAEDbS described in section 1606(c) of this Article.

 

(e)   Modified and Discontinued Appliances.

Text

Description automatically generated with medium confidence

(1) If any of the characteristics listed in Table X are changed, the manufacturer shall file a statement containing the identifiers and all the information for the appliance, including all the characteristics that have been changed for the appliance. Upon receipt of such a statement, the Executive Director shall review the statement under section 1606(b) of this Article. If the statement is complete, accurate, in compliance with all applicable standards, the Executive Director shall modify the MAEDbS accordingly.

(A) If no data currently certified for a specific appliance has changed, no notification of modification is necessary, nor will it be accepted in MAEDbS.

(2)  After any appliance has ceased being sold or offered for sale in California the manufacturer shall file a statement so stating and only containing the identifiers shown in Table X for the appliance. Upon receipt of such a statement, the Executive Director shall review the statement under section 1606(b) of this Article. If the statement is complete, accurate, and in compliance with all applicable provision of this Article s, the Executive Director shall modify MAEDbS.

(A) Section 1606(e)(2) of this Article applies either when:

1. a manufacturer or third-party certifier provides information about deleting a model, or

2. Energy Commission Appliance Efficiency Program staff independent of any manufacturer or third-party certifier determine that an appliance has ceased being sold or offered for sale in California.

(3) If a manufacturer of a computer fails to obtain two ISV certifications within 60 days of certifying a computer model or loses ISV certifications such that the computer model no longer meets the definition of a workstation or mobile workstation, that manufacturer shall either file to remove the appliance from the database as described in Section 1606(e)(2) of this Article or shall modify the model certification as described in Section 1606(e)(1) of this Article to comply as a different computer type.

 

(f)    Filing by Third Parties.

Text

Description automatically generated with medium confidence

(1)   A third party may file on behalf of a manufacturer the information required by sections 1606(a)(2), 1606(a)(3), 1606(a)(4), 1606(c)3 or 1606(e) of this Article if:

(A)  before or with its first submittal, the third party submits through the MAEDbS a declaration, under penalty of perjury, that:

1. the third party has read and understood all the provisions of this Article, of federal law, and of all other documents applicable to each appliance category in section 1601(a)-(x) of this Article for which the third party will file information, including but not limited to updated test procedures, standards and filing requirements; and

2. the third party is financially and technically capable of complying with the applicable provisions of this Article;

(B)  before or with the first submittal made by the third party, the manufacturer submits to the third party and Executive Director through the MAEDbS:

1.   a declaration under penalty of perjury,

a.    that all information provided to the third party by the manufacturer is true, complete, accurate, and in compliance with all applicable provisions of this Article,

b.   that no unmodified model data is being submitted.

c.    that on behalf of the manufacturer, the third party is authorized to file information in compliance with the provisions of this Article, and

d.   for appliances for which there is an energy efficiency, energy consumption, energy design, water consumption, water efficiency, or water design standard in section 1605.1, 1605.2, or Section 1605.3, that the model complies with the applicable standards.

(C)  the third party submits to the Executive Director, through the MAEDbS in compliance with the requirements of this Article applicable to manufacturerfiled submittals:

1.   the information that is required; and

2.   a declaration under penalty of perjury that:

a.    to the best of the third partyʹs knowledge and belief, the information submitted to the Energy Commission is the same as the information submitted by the manufacturer to the third party;

b.   the information is true, complete, accurate, and in compliance with all applicable provisions of this Article; and,

c.    for appliances for which there is an energy efficiency, energy design, water consumption, or water efficiency standard in Section 1605. 1, 1605.2, or Section 1605.3, of this Article the appliance complies with the applicable standards.

(D) the third party provides, upon ten days' written notice from the Executive Director, all information provided by the manufacturer

(1)  Whether a manufacturer files information required by this Section by itself or via a third party, the manufacturer remains responsible for the truth, accuracy, completeness, and timeliness of all required filings.

(2)  Upon a finding of noncompliance with an applicable provision of this Article, the Executive Director may suspend a third party from making filings, allow continued filings under specific conditions or remove affected appliances from MAEDbS.

(3)  If the Executive Director has suspended or revoked the approval of a trade association directory under Section 1606(h)(2)(B), that trade association is prohibited from being approved as a third party until it has obtained reapproval under Section 1606(h)(2)(B).I

(4)  if the Executive Director has suspended or revoked the approval of a trade association directory under section 1606(h)(2)(B) of this Article, that trade association is prohibited from being approved as a third party until it has obtained re-approval under section 1606(h)(2)(B) of this Article.

(5)  The provisions of this Article are applicable to all submittals and filings, whether made by a manufacturer directly or by a third party on behalf of a manufacturer.

 

(g)   Electronic Filing.

Text

Description automatically generated with medium confidence

(1) Unless otherwise stated in this Article, the statements and other submittals required or allowed by this Article shall be filed electronically to the MAEDbS by all third parties acting under section 1606(f) of this Article so that the electronic filing to the MAEDbS uses a format and characteristics, including without limitation appropriate formatting, that are specified by the Executive Director, and includes a declaration that complies with section 1606(a)(4) of this Article.

(2) Any electronic filing to the MAEDbS constitutes a representation by the person making the filing that:

(A) all applicable requirements of this Article have been met;

(B) the person will electronically acknowledge receipt through the MAEDbS of all electronic communications concerning the filing from the Executive Director through the MAEDbS to the person;

(C) all electronic communications concerning the filing from the Executive Director through the MAEDbS to the person shall be deemed received by the person upon notification to the Executive Director, by the computer from which the Executive Director communication has been sent, that the communication has been sent; and

(D) all electronic communications concerning the filing from the person to the Executive Director shall be deemed received by the Executive Director only upon actual receipt.

(3) At any time the Executive Director may forbid electronic filings by any person, or generically, and may remove affected appliance models from the MAEDbS, if he or she finds that an applicable requirement of this Article is not being met

 

(h)   Trade Association Directories.

Text

Description automatically generated with medium confidence

(1)  A paper or electronic directory, or a part thereof, published by an appliance trade association may be used for any purpose that the MAEDbS established pursuant to Section 1606(c) of this Article is used for, if the Executive Director approves the directory, or part thereof, by determining and confirming that:

(A)  the trade association is an approved industry certification program within the MAEDbS and meets all requirements shown in section 1603(b) of this Article. or each appliance listed in the directory;

(B)  all of the applicable requirements of section 1606(f) of this Article for third party submittals are met for the directory;

(C)  the entity submits to the Executive Director:

1.   all of the information in the directory, within three working days of the approval of the directory;

2.   all of the information in the directory that has changed since the previous submittal, at the end of each month during which there has been any change;

3.   a declaration, signed under penalty of perjury of the laws of California, that to the best of the trade associationʹs knowledge and belief:

a.    the information in the directory is the same as the information submitted by manufacturers to the trade association;

b.   the information is true, complete, accurate, and in compliance with all applicable provisions of this Article;

c.    each appliance complies with the applicable standards in Section 1605.1 of this Article; and

d.   for any appliance for which there is a standard in section 1605.3, that the appliance meets all applicable standards unless the directory states, in a format approved by the Executive Director (including without limitation font, type size, and placement in the directory), that it is illegal in California to sell the appliance or offer it for sale.

(D)  for each appliance that is listed in a trade association directory, the directory includes all of the following information, where applicable to the appliance:

1.  manufacturer

2.  brand

3.  model number as it appears on the appliance

4.  type

5.  fuel type

6.  voltage

7.  electrical phase

8.  capacity or other size measurement

9.  input

10. output

11. standby consumption, loss, or other similar measurement; and energy efficiency,

12. energy consumption, water efficiency, or water consumption;

 

(E)  the directory contains no appliance in the following categories:

1.   an appliance that fails to meet an applicable energy efficiency, energy consumption, energy design, water efficiency, or water consumption standard established in or pursuant to NAECA or EPAct;

2.   an appliance for which the manufacturer has stated or certified that the appliance meets an energy efficiency, energy consumption, energy design, water efficiency, or water consumption standard not applicable to it; or

3.   an appliance that does not, or an appliance whose manufacturer does not, meet an applicable requirement of this Article, unless the directory states, in a format approved by the Executive Director (including without limitation font, type size, and placement in the directory), that it is illegal in California to sell the appliance or offer it for sale; and

(F)  each paper or electronic directory contains the following statement, in at least 20 point bolded type and on the front cover or first page, or in another format and with other characteristics as specified by the Executive Director:

“This directory [insert parts if appropriate] has been approved by the California Energy Commission (Energy Commission) for determining compliance with its appliance efficiency regulations (Title 20, California Code of Regulations, Sections 16011608) and its building standards (Title 24, California Code of Regulations, Part 6). UNLESS INDICATED OTHERWISE, any appliance listed in this directory [insert parts if appropriate] may be sold, offered for sale, or installed in new construction in California. For appliances manufactured by manufacturers participating in this directory, but who have not given authorization for data submittal to the Energy Commission, this directory cannot be used for determining compliance. For information about such appliances, appliances that are beyond the scope of this directory, or appliances produced by manufacturers who do not participate in this directory, please contact the Appliance Efficiency Program at: <appliances@energy.ca.gov>. Manufacturers not granting authorization for data submittal to the Energy Commission as of the publication date of this directory include [list all affected manufacturers]”; and

(G)  at the end of each calendar quarter, the trade association provides, at no cost to recipients, an electronic copy of the current directory or supplement or part thereof to the Executive Director and to all California building officials as specified by the Executive Director, and provides to the Executive Director a list of the building officials to whom the directory or supplement was sent.

(2)  If the Executive Director at any time determines that an approved trade association directory does not comply with an applicable provision of this Article, or that any information in a trade association directory is substantially incomplete, inaccurate, or not in compliance with an applicable provision of this Article, then:

(A)  upon written notice from the Executive Director the trade association shall immediately indicate in the directory, in a format approved by the Executive Director (including without limitation font, type size, and placement in the directory), that it is illegal in California to sell the appliance. In addition, the Executive Director shall remove the appliance from the the Energy Commissionʹs MAEDbDs established under Section 1606(c) of this Article or indicate in the database that the appliance cannot legally be sold or offered for sale in California. The appliance shall be removed from, or indicated in, the Energy Commissionʹs MAEDbDs and the trade association directory, for at least sixty days, until the end of a proceeding held to consider the matter pursuant to Sections 11445.1011445.60 of the California Government Code (or, at the third party or affected manufacturerʹs option, pursuant to Sections 11425.1011425.60 of the California Government Code); and

(B)  the Executive Director may suspend or revoke the approval of the trade association directory; if approval is revoked, the trade association may not seek reapproval for two years after the revocation.

(3)  If the Executive Director takes action under sections 1606(b)(3)(A) or (B), or 1608(c), (d), or (e), of this Article he or she shall direct that all trade association directories be modified accordingly.

(4)  There may be more than one thirdparty directory for the same appliance.

 

(i)    Retention of Records.

Manufacturers, and third parties or trade associations acting under sections 1606(a), 1606(f) of this Article and 1606(g), shall retain all data, forms, information, and all other records required by this Article concerning each appliance:

(1)  for at least 2 years after the manufacturer informs the Executive Director, in writing, of the cessation of production of the appliance; and

(2)  in a manner allowing ready access by the Executive Director on request.

The Executive Director shall retain all data, forms, information, and all other records required by this Article concerning each appliance for at least 10 years after the record is initially filed or reconfirmed.

 

(j)    Small Volume Manufacturers.

(1) Entities seeking to be designated as a “small volume manufacturer” for purposes of Section 1605.3(v)(7) of this Article shall certify and retain records to demonstrate the following information:

(A) Gross revenues from the 12-month period preceding the certification from all of the entity's operations, including operations of any other person or business entity that controls, is controlled by, or is under common control of the entity, is $2,000,000 or less; and

(B) The manufacturer assembles and sells the computers at the same location.

(2) If a small volume manufacturer no longer meets one of the requirements to be a small volume manufacturer, the entity shall file to remove itself from the database as a small volume manufacturer within 90 days.

 

The following documents are incorporated by reference in section 1606.

 

Number

Title

CALIFORNIA ENERGY COMMISSION

California Energy Commission Voluntary California Quality Light-Emitting Diode (LED) Lamp Specification (December 2014)

California Title 24, Part 6,

Qualification Requirements

Joint Appendix 8 JA-8 - 2015

for High Efficacy Light Sources

Copies available from:

CALIFORNIA ENERGY COMMISSION

ENERGY HOTLINE

1516 NINTH STREET, MS-25

SACRAMENTO, CALIFORNIA 95814

PHONE: (916) 654-5106

FAX: (916) 654-4304

FEDERAL STATUTES AND REGULATIONS

C.F.R., Title 10, section

Uniform Test  Method for Measuring

430.23(ee) (Appendix BB to subpart B of part 430)

The Input Power, Lumen Output,

(Jan. 1, 2017)

Lamp Efficacy, Correlated Color

Temperature (CCT), Color Rendering

Index (CRI), Power Factor, Time to

Failure, and Standby Mode Power of

 

Integrated Light-Emitting Diode

 

(LED) Lamps

 

 

Copies available from:

SUPERINTENDENT OF DOCUMENTS

U.S. GOVERNMENT PRINTING OFFICE

WASHINGTON D.C. 20402

http://www.gpo.gov

 

 

NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA)

NEMA SSL 7A (2013)

Phase Cut Dimming for Solid State

Lighting: Basic Compatibility

Copies available from:

NATIONAL ELECTRIC MANFACTURERS

ASSOCIATION

1300 N. 17TH STREET, SUITE 1847

ROSSLYN, VA 22209

www.nema.org

PHONE: (703) 841-3200

FAX: (703) 841-3300

 

Note: Authority cited: Sections 25213, 25218(e), 25401.9(b), 25402(a)-25402(c), and 25960, Public

Resources Code; and sections 16, 26, and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015).

Reference: Sections 25216.5(d), 25401.9(b), 25402(a)-25402(c), 25402.5.4, and 25960, Public

Resources Code; and section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).

 

HISTORY

1. Order of Repeal of subsections (c)(7)(F)1, (c)(7)(F)2 and (d) filed 6-3-85 by OAL pursuant to Government Code section 11349.7; effective thirtieth day thereafter (Register 85, No. 26). For prior history, see Register 83, No. 18.

2. Amendment of subsection (c)(7)(C) filed 3-3-86; effective thirtieth day thereafter (Register 86, No. 10).

3. Amendment filed 7-20-87; operative 8-19-87 (Register 87, No. 30).

4. Amendment filed 8-29-88; operative 9-28-88 (Register 88, No. 37).

5. Amendment filed 6-5-90; operative 7-5-90 (Register 90, No. 31).

6. Amendment of subsections (a), (b), (d) and (f) filed 11-6-91; operative 12-6-91 (Register 92, No. 9).

7. Amendment of Table J and subsection (b)(9) filed 7-23-92; operative 8-24-92 (Register 92, No. 35).

8. Repealer and new section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).

9. Amendment of subsections (a) and (a)(3)(D)-(a)(3)(E)3.b., Table U and subsection (b)(2)(A) filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.

10. Certificate of Compliance as to 4-1-2003 order, including amendment of Table U footnote, transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).

11. Amendment of Table U, subdivision P, filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).

12. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).

13. Amendment of Exceptions to subsection (a) and subsection (a)(2)(A), repealer of Exception and new Exceptions 1-3 to subsection (a)(3)(D), amendment of Table V, parts A, C, D, G, K, N and U, new subsections (a)(4)(A)4.-(a)(4)(A)5.h., amendment of subsection (c)(1)(A) and new subsections (f)(1)(F)-(f)(1)(F)4. filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).

14. Amendment of Table V-D, V-F, V-G, V-K and V-N and subsection (a)(4)(A)5.f., and amendment of Note filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).

15. Amendment of subsection (a) - Table V and subsections (b)(2)-(b)(2)(A) filed 8-22-2007; operative 9-17-2007 pursuant to Government Code section 11343.4 (Register 2007, No. 34).

16. Amendment of subsection (a) - Table V filed 11-29-2007; operative 12-29-2007 (Register 2007, No. 48).

17. Amendment of subsection (a), and subdivisions thereof, including redesignation of former Table V as new Table X, amendment of subsections (c)(1)(A)-(c)(2), (e)(1)-(2), (f)(1)(A)1. and (f)(1)(F) filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).

18. Amendment of subsection (a) - Table X-K and X-N, new subsection (j) and amendment of Note filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).

19. Amendment of subsection (a) - Table X-V and new subsections (a)(4)(A)5.j.-k. filed 9-1-2010; operative 1-1-2011 (Register 2010, No. 36).

20. New Exception 4 to subsection (a)(3)(D), amendment of subsection (a) - Table X-L and X-W and new subsection (a)(4)(A)4.m. filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).

21. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).

22. Amendment of subsection (a) - Table X-H and Table X-I, new subsection (a)(4)(A)4.j. and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5-15-2015 (Register 2015, No. 20).

23. Amendment of subsection (a)(3)(E) - Table X-H filed 8-20-2015; operative 8-20-2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).

24. Amendment of subsection (a)(3)(E) - Table X filed 6-30-2016; operative 7-1-2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).

25. Amendment of subsection (k) and list of documents incorporated by reference filed 11-1-2016; operative 1-1-2017 (Register 2016, No. 45).

26. Amendment of subsection (a)(3)(E) - Table X-G filed 3-27-2017 as an emergency; operative 3-27-2017 (Register 2017, No. 13). A Certificate of Compliance must be transmitted to OAL by 9-25-2017 or emergency language will be repealed by operation of law on the following day.

27. Amendment of subsection (a)(3)(E) - Table X-C filed 3-27-2017 as an emergency; operative 3-27-2017 (Register 2017, No. 13). A Certificate of Compliance must be transmitted to OAL by 9-25-2017 or emergency language will be repealed by operation of law on the following day.

28. Amendment of Table X, part V and new subsections (e)(3) and (k)-(k)(2) filed 8-22-2017; operative 10-1-2017 (Register 2017, No. 34).

29. Change without regulatory effect amending subsection (a)(4)g. filed 9-11-2017 pursuant to section 100, title 1, California Code of Regulations (Register 2017, No. 37).

30. Certificate of Compliance as to 3-27-2017 order transmitted to OAL 8-25-2017 and filed 10-5-2017 (Register 2017, No. 40).

31. Amendment of subsection (a)(3)(E)3.b., Table X-V and subsection (k)(2) filed 1-25-2018; operative 1-25-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 4).

32. Amendment of Table X-G filed 7-19-2018; operative 10-1-2018 (Register 2018, No. 29).

33. Amendment of section heading, section and Note filed 9-26-2018; operative 10-1-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).

34. Editorial correction of subsections (a) and (a)(3)(C) and Table X - sections C, G, J, S and T (Register 2018, No. 45).

35. Editorial correction of Table X (Register 2019, No. 11).

36. Change without regulatory effect amending subsection (a), Table X and list of documents incorporated by reference filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).

37. Amendment of subsection (a)(1), new subsection (a)(1)(H) and amendment of Table X filed 3-18-2019; operative 3-18-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 12).

38. Amendment of subsections (a), (a)(3)(A) and (a)(3)(C) and Table X and new subsection (a)(4)(A)4.i. filed 6-10-2019; operative 6-10-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).

39. Amendment of Table X adding new section (X) and amendment of Note filed 10-7-2019; operative 10-1-2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).

40. Amendment of EXCEPTIONS to subsection (a) and Table X - section K filed 12-24-2019; operative 1-1-2020 (Register 2019, No. 52).

41. Amendment of subsection (a)(3)(A) adding Exceptions 2. and 3., amendment of Table X - section G and subsection (a)(4)(A)5.g. and new subsection (a)(4)(A)5.i. filed 9-21-2020; operative 1-1-2021 (Register 2020, No. 39). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-66-20.

42. Amendment of Table X, section V filed 2-3-2021; operative 12-9-2021 pursuant to Government Code section 11343.4(b)(1) and Public Resources Code section 25402(c)(1) (Register 2021, No. 6).

43. Amendment of subsections (a)(3)(A), amendment of Table X, sections A, D, G, L and X, amendment of subsections (c)(4)(A)4.h.-i., (e)(3), (f)(1)(A)1. and (j)(1) filed 3-16-2021; operative 3-16-2021 pursuant to Government Code section 11343.4(b)(3) (Register 2021, No. 12). (Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20.)

44. Change without regulatory effect amending subsection (a)(3)(C) - Exception 3., Table X, section V and subsections (a)(4)(A)5.i., (c)-(c)(1) and (h)(1)(A) filed 7-12-2021 pursuant to section 100, title 1, California Code of Regulations (Register 2021, No. 29).

45. Amendment of Table X - section G filed 9-8-2021; operative 1-1-2022 (Register 2021, No. 37).

46. Change without regulatory effect amending subsections (a)(1)(E), (a)(2)(B), (d)(1), (g)(3) and (h)(3) filed 8-24-2022 pursuant to section 100, title 1, California Code of Regulations (Register 2022, No. 34).

47. Amendment of Table X section D adding “Commercial and Industrial Fans and Blowers” filed 1-17-2023; operative 11-16-2023 (Register 2023, No. 3).

48. New subsection (a)(1)(I), amendment of Table X -- section C and amendment of list of documents incorporated by reference filed 4-7-2023; operative 7-1-2024 (Register 2023, No. 14).

49. Repealer of subsection (n)(3) - Portable luminaires and amendment of subsection (a)(4) - EXCEPTIONS to section 1606(a)(4)(A)4. filed 4-25-2023; operative 4-25-2023 pursuant to Government Code section 11343.4(b)(3) (Register 2023, No. 17).

 

This database is current through 4/19/24 Register 2024, No. 16.

Cal. Admin. Code tit. 20, § 1606, 20 CA ADC § 1606