APPENDIX 1-A
STANDARDS AND DOCUMENTS REFERENCED IN THE ENERGY EFFICIENCY REGULATIONS

AIR-CONDITIONING, heating AND REFRIGERATION INSTITUTE

AHRI 210/240-2008

Performance Rating of Unitary Air Conditioning and Air-Source Heat Pump Equipment (2008 with Addendum 1)

ANSI/AHRI/CSA 310/380-2004

Standard for Packaged Terminal Air-Conditioners and Heat Pumps (2004)

AHRI 320-98

Water-Source Heat Pumps

AHRI 325-98

Ground Water-Source Heat Pumps (1998)

ANSI/AHRI 340/360-2007

Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment (2007 with Addenda 1 and 2)

ANSI/AHRI 365-2009

Commercial and Industrial Unitary Air-Conditioning Condensing Units (2009)

ANSI/AHRI 460-2005

Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant Condensers (2005)

AHRI 550/590-2011

Performance Rating of  Water-Chilling Packages Using the Vapor Compression Cycle (2011)

ANSI/AHRI 560-2000

Absorption Water Chilling and Water Heating Packages (2000)

AHRI 680

Available from:

Performance Rating of Residential Air Filter Equipment (2009)

Air-Conditioning and Refrigeration Institute

 

4301 North Fairfax Drive, Suite 425

 

Arlington, Virginia 22203

 

(703) 524-8800

 

AIR CONDITIONING CONTRACTORS OF AMERICA

'Manual J – Residential Load Calculation, Eighth Edition (2003)

Available from:

Air Conditioning Contractors of America, Inc.

 

2800 Shirlington Road, Suite 300

 

Arlington, VA 22206

 

www.acca.org

 

(703) 575-4477

 

AMERICAN NATIONAL STANDARDS INSTITUTE

ANSI Z21.10.3-2001

Gas Water Heaters, Volume 1, Storage Water Heaters with Input Ratings above 75,000 Btu/h (2001)

ANSI Z21.13-2000

Gas-Fired Low Pressure Steam and Hot Water Boilers (2000)

ANSI Z21.40.4-1996

Performance Testing and Rating of Gas-Fired, Air-Conditioning and Heat Pump Appliances (1996)

ANSI Z21.47-2001

Gas-Fired Central Furnaces (2001)

ANSI Z83.8-2002

Gas Unit Heaters and Gas-Fired Duct Furnaces (2002)

Available from:

American National Standards Institute

 

25 West 43rd Street, 4th Floor

 

New York, NY 10036

 

(212) 642-4900

ANSI/NSPI-5 2003

Residential Inground Swimming Pools (2003)ANSI C82.6-2005

 

Ballasts for High-Intensity Discharge Lamps - Methods of Measurement

Available from:

Association of Pool & Spas Professionals

 

2111 Eisenhower Ave.

 

Alexandria, VA 22314

 

(703) 838-0083

 

AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING ENGINEERS (NATIONAL PUBLICATIONS)

ASHRAE Standard 55-2004

Thermal Environment Conditions for Human Occupancy

ASHRAE Standard 62.2-2007

Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

ASHRAE Handbook

 

        Applications Volume,

Heating, Ventilating and Air-Conditioning Applications (2011)

        Equipment Volume,

Heating, Ventilating and Air-Conditioning Systems and Equipment (2008)

        Fundamentals Volume,

Fundamentals (2009)

Available from:

ASHRAE

 

1791 Tullie Circle N.E.

 

Atlanta, Georgia 30329-2305

 

www.ashrae.org

 

AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING ENGINEERS (REGIONAL PUBLICATION)

ASHRAE Climatic Data for Region X Arizona, California, Hawaii, Nevada, Publication SPCDX, 1982, ISBN #20002196 and Supplement, 1994, ISBN #20002596

Available from:

Order Desk

 

Building News

 

10801 National Boulevard

 

Los Angeles, CA 90064

 

(800) 873-6397 or (310) 474-7771

 

www.bnibooks.com

 

AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASME A112.18.1-2011/CSA B125.1-11

Plumbing Supply Fittings

Available from:

ASME

 

Three Park Avenue

 

New York, NY 10016-5990

 

(800) 843-2763

 

www.asme.org

 

 

AMERICAN SOCIETY FOR TESTING AND MATERIALS

ASTM C55-01

Standard Specification for Concrete Brick (2001)

ASTM C177-97

Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded Hot Plate Apparatus (1997)

ASTM C272-01

Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions (2001)

ASTM C335-95

Standard Test Method for Steady State Heat Transfer Properties of Horizontal Pipe Insulation (1995)

ASTM C518-02

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus (2002)

ASTM C731-00

Standard Test Method for Extrudability, After Package Aging, of Latex Sealants (2000)

ASTM C 732-01

Standard Test Method for Aging Effects of Artificial Weathering on Latex Sealants (2001)

ASTM C 1167-96

Standard Specification for Clay Roof Tiles

ASTM C1371-98

Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers (1998)

ASTM D822-01

Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings (2001)

ASTM D1003-00

Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics (2000)

ASTM D2824-02

Standard Specification for Aluminum-Pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered, and Fibered without Asbestos, 2002

ASTM D3805-97

Standard Guide for Application of Aluminum-Pigmented Asphalt Roof Coatings, 1997 (reapproved 2009)

ASTM D4798-01

Standard Test Method Accelerated Weathering Test Conditions and Procedures for Bituminours Materials (Xenon-Arc Method) (2001)

 

 

ASTM E96-00

Standard Test Methods for Water Vapor Transmission of Materials

ASTM E 283-91 (1999)

Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM E408-71(2008)

Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques (2008)

ASTM E972 - 96(2007)

Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight.

ASTM E1980 – 01

Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped opaque Surfaces

ASTM E2178-03

 

Standard Test Method for Air Permeance of Building Materials

ASTM E2357-05

 

Standard Test Method for Determining Air Leakage of Air Barrier Assemblies

ASTM E779-03

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

ASTM E1677-95 (2000)

Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls

ASTM C836-05

Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course (2005)

ASTM C1583-04

Standard Test Method for Tensile Strength of Concrete Surfaces and the Bond Strength or Tensile Strength of Concrete Repair and Overlay Materials by Direct Tension (Pull-off Method) (2004)

ASTM D522-93a (2001)

Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings (2001)

ASTM D1653-03

Standard Test Methods for Water Vapor Transmission of Organic Coating Films (2003)

ASTM D2370-98 (2002)

Standard Test Method for Tensile Properties of Organic Coatings (2002)

ASTM D3468-99

Standard Specification for Liquid-Applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing (1999)

ASTM D5870-95 (2003)

Standard Practice for Calculating Property Retention Index of Plastics (2003)

ASTM D6083-05e1

Standard Specification for Liquid Applied Acrylic Coating Used in Roofing (2005)

ASTM D6694-01

Standard Specification for Liquid-Applied Silicone Coating Used in Spray Polyurethane Foam Roofing (2001)

Available from:

American Society for Testing and Materials

 

100 Barr Harbor Drive

 

West Conshohocken, Pennsylvania 19428-2959

 

(800) 262-1373 or (610) 832-9585

 

CALIFORNIA BUILDING STANDARDS COMMISSION

2010 California Electrical Code

2010 California Plumbing Code

2010 California Mechanical Code

2010 California Building Code

Available from:

California Building Standards Commission

 

2525 Natomas Park Drive, Suite 130

 

Sacramento, CA 95833-2936

 

(916) 263-0916

 

http://www.bsc.ca.gov

 

 

CALIFORNIA ENERGY COMMISSION

Appliance Efficiency Regulations

 

Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Reference Appendices for the Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Nonresidential Alternative Calculation Method (ACM) Approval Manual

Nonresidential Alternative Calculation Method (ACM) Reference Manual

Nonresidential Compliance Manual

 

Residential Alternative Calculation Method (ACM) Approval Manual

Residential Alternative Calculation Method (ACM) Reference Manual

Residential Compliance Manual

 

New Solar Homes Partnership Guidebook, currently adopted by the Energy Commission.

Available from:

California Energy Commission/Publications

 

1516 Ninth Street

 

Sacramento, CA 95814

 

(916) 654-5200

 

www.energy.ca.gov/title24.

 

CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS

Standards for Insulating Material

Available from:

California Department of Consumer Affairs

 

Bureau of Home Furnishings and Thermal Insulation

 

3485 Orange Grove Ave

 

North Highlands, CA 95660

 

(916) 574-2041

 

COOLING TECHNOLOGY INSTITUTE

CTI ATC-105-00

Acceptance Test Code for Water Cooling Towers (2000)

CTI STD-201-04

Standard for the Certification of Water-Cooling Tower Thermal Performance (2004)

Available from:

Cooling Technology Institute

 

2611 FM 1960 West, Suite A-101

 

Houston, Texas 77068-3730

 

 

 

PO Box 73383

 

Houston, Texas 77273-3383

 

(281) 583-4087

 

 

 

 

 

 

COOL ROOF RATING COUNCIL

CRRC-1

 

Product Rating Program Manual (2007)

Available from:

Cool Roof Rating Council

 

1610 Harrison Street

 

Oakland, CA 94612

 

(866) 465-2523

 

www.coolroofs.org

 

HYDRONICS INSTITUTE

HI Heating Boiler Standard 86, 6th Edition, (1989)

Available from:

Hydronics Institute

 

35 Russo Place, P.O. Box 218

 

Berkeley Heights, New Jersey 07922

 

(908) 464-8200

 

 

 

ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA

The IESNA Lighting Handbook, Ninth Edition (2000)

Available from:

IESNA

 

120 Wall Street, 17th Floor

 

New York, New York 10005-4001

 

(212) 248-5000

 

Email: iesna@iesna.org

 

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

2007 California Mechanical Code

Available from:

International Association of Plumbing and Mechanical Officials

 

2001 E. Walnut Drive South

 

Walnut, California 91789-2825

 

800 85-IAPMO (854-2766)

 

www.iapmo.org

 

INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS

2007 California Building Code

Available from:

International Conference of Building Officials

 

International Code Council Los Angeles District Office

 

5360 South Workman Mill Road

 

Whittier, California 90601-2298

 

(800) 284-4406

 

www.icbo.org

 

INTERNATIONAL ORGANIZATION FOR STANDARDIZATION

ISO-13256-1

Water-Source Heat Pumps - Testing and Rating for Performance - Part 1: Water-to-Air and Brine-to-Air Heat Pumps (1998)

Available from:

ISO

 

1, rue de Varembe

 

Case postale 56

 

CH-1211

 

Geneve 20, Switzerland

 

NATIONAL FENESTRATION RATING COUNCIL

NFRC 100

 

Procedures for Determining Fenestration Product U-factors (2011)

NFRC 200

 

Procedures for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence (2011)

NFRC 202

 

Procedure for Determining Translucent Fenestration Product Visible Transmittance at Normal Incidence (2011)

Note: This Technical document has yet not been fully approved by NFRC. If this document is not approved before the Building Energy Standards effective date it will be removed.

NFRC 203

 

Procedure for Determining Visible Transmittance of Tubular Daylighting Devices (2012)

Note: This Technical document has yet not been fully approved by NFRC. If this document is not approved before the Building Energy Standards effective date it will be removed.

NFRC 400

 

Procedures for Determining Fenestration Product Air Leakage (2010)

Available from:

National Fenestration Rating Council

 

8484 Georgia Ave.

 

 Silver Spring, MD 20910

 

(301) 589-1776

 

WWW.NFRC.org and Email: info@nfrc.org

 

NSF INTERNATIONAL (formerly National Sanitation Foundation)

NSF/ANSI 50 2005

Circulation System Components and Related Materials for Swimming Pools, Spas/Hot Tubs (2005)

Available from:

NSF International

 

PO Box 130140

 

Ann Arbor, MI 48113

 

(734) 769-8010

 

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION

Residential Comfort System Installation Standards Manual (1998)

Available from:

Sheet Metal And Air Conditioning Contractors National Association (SMACNA)

 

4201 Lafayette Center Drive

 

Chantilly, VA 20151-1209

 

(703) 803-2980

 

www.smacna.org

 

UNDERWRITERS LABORATORIES

UL 181

Standard for Safety for Factory-made Air Ducts and Connectors (1996)

UL 181A

Standard for Safety for Closure Systems for Use with Rigid Air Ducts and Air Connectors (1994)

UL 181B

Standard for Safety for Closure Systems for Use with Flexible Air Ducts and Air Connectors (1995)

UL 723

Standard for Test for Surface Burning Characteristics of Building Materials (1996)

UL 727

 

Standard for Oil-Fired Central Furnaces (1994)

UL 731

 

Standard for Oil-Fired Unit Heaters (1995)

UL 1574

Track Lighting Systems (2000)

UL 1598

Standard for Luminaires (2000)

UL 2108

Low Voltage Lighting Systems (2008)

Available from:

Underwriters Laboratories

 

333 Pfingsten Road

 

Northbrook, Illinois 60062-2096

 

(847) 272-8800