The following documents are incorporated by reference to the extent they are referenced in the Energy Efficiency Regulations.
AIR-CONDITIONING, heating AND REFRIGERATION INSTITUTE
AHRI 210/240-2008 |
Performance Rating of Unitary Air Conditioning and Air-Source Heat Pump Equipment (2008 with Addendum 1) |
Standard for Packaged Terminal Air-Conditioners and Heat Pumps (2017) | |
AHRI 320-98 |
Water-Source Heat Pumps |
AHRI 325-98 |
Ground Water-Source Heat Pumps (1998) |
ANSI/AHRI 340/360-2015 |
Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment (2015) |
ANSI/AHRI 365-2009 ANSI/AHRI 390-2003 ANSI/AHRI 400-2015 |
Commercial and Industrial Unitary Air-Conditioning Condensing Units (2009) Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps Liquid to Liquid Heat Exchangers (2015) |
ANSI/AHRI 460-2005 |
Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant Condensers (2005) |
AHRI 550/590-2015 |
Performance Rating of Water-Chilling Packages Using the Vapor Compression Cycle (2015) |
ANSI/AHRI 560-2000 |
Absorption Water Chilling and Water Heating Packages (2000) |
AHRI 1230-2014 Available from: |
Performance Rating of Residential Air Filter Equipment (2015) Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment (w/ Addendum 1) Air-Conditioning and Refrigeration Institute |
|
4301 North Fairfax Drive, Suite 425 |
|
Arlington, Virginia 22203 |
|
(703) 524-8800 |
AIR CONDITIONING CONTRACTORS OF AMERICA
Manual J – Residential Load Calculation, Eighth Edition (2016) | |
Available from: |
Air Conditioning Contractors of America, Inc. |
|
2800 Shirlington Road, Suite 300 |
|
Arlington, VA 22206 |
|
www.acca.org |
|
(703) 575-4477 |
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION
CANADIAN STANDARDS ASSOCIATION
WINDOW AND DOOR MANUFACTURERS ASSOCIATION
AAMA/WDMA/CSA 101/I.S.2/A440-11
Available from: |
NAFS 2011 – North American Fenestration Standard/Specification for windows, doors, and skylights
AAMA 1827 Walden Office Square, Suite 550 Schaumburg, IL 60173-4268 (847)303-5664 www.aamanet.org
CSA 5060 Spectrum Way, Suite 100 Mississauga, ON, Canada L4W 5N6 (800)463-6727 www.csagroup.org
WDMA 2025 M Street, NW, Suite 800 Washington, DC 20036-3309 (202)367-1157 www.wdma.com |
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGENISTS
2018 Threshold Limit Values (TLVS) and Biological Exposure Indices (BEIS)
Available from: |
ACGIH 1330 Kemper Meadow Drive Cincinnati, Ohio 45240 (513) 742-2020 www.acgih.org |
AMERICAN NATIONAL STANDARDS INSTITUTE
ANSI Z21.10.3-2017 |
Gas Water Heaters, Volume 1, Storage Water Heaters with Input Ratings above 75,000 Btu/h (2017) |
ANSI Z21.13-2017 |
Gas-Fired Low Pressure Steam and Hot Water Boilers (2017) |
ANSI Z21.40.4-2017 |
Performance Testing and Rating of Gas-Fired, Air-Conditioning and Heat Pump Appliances (2017) |
ANSI Z21.47-2016 |
Gas-Fired Central Furnaces (2016) |
ANSI Z83.8-2016 |
Gas Unit Heaters and Gas-Fired Duct Furnaces (2016) |
Available from: |
American National Standards Institute |
|
25 West 43rd Street, 4th Floor |
|
New York, NY 10036 |
|
(212) 642-4900 |
ANSI/NSPI-5 2003
|
Residential Inground Swimming Pools (2003)
|
ANSI C82.6 - 15 |
Ballasts for High-Intensity Discharge Lamps - Methods of Measurement - 2015 |
Available from: |
Association of Pool & Spas Professionals |
|
2111 Eisenhower Ave. |
|
Alexandria, VA 22314 |
|
(703) 838-0083 |
AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING ENGINEERS (NATIONAL PUBLICATIONS)
ASHRAE Standard 52.2 -2017 |
Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size |
ASHRAE Standard 55-2017 |
Thermal Environment Conditions for Human Occupancy |
ASHRAE Standard 62.2-2016 ASHRAE 193 - RA2014 |
Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings Method of Test for Determining the Airtightness of HVAC Equipment (RA2014) |
ASHRAE Handbook |
|
Applications Volume, |
Heating, Ventilating and Air-Conditioning Applications (2015) |
Equipment Volume, |
Heating, Ventilating and Air-Conditioning Systems and Equipment (2016) |
Fundamentals Volume, |
Fundamentals (2017) |
Available from: |
ASHRAE |
|
1791 Tullie Circle N.E. |
|
Atlanta, Georgia 30329-2305 |
|
www.ashrae.org |
AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING ENGINEERS (REGIONAL PUBLICATION)
ASHRAE Climatic Data for Region X Arizona, California, Hawaii, Nevada, Publication SPCDX, 1982, ISBN #20002196 and Supplement, 1994, ISBN #20002596 | |
Available from: |
Order Desk |
|
Building News |
|
10801 National Boulevard |
|
Los Angeles, CA 90064 |
|
(800) 873-6397 or (310) 474-7771 |
|
http://www.bnibooks.com/ |
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASME A112.18.1-2012/CSA B125.1-12 ASME A17.1 -16 |
Plumbing Supply Fittings Handbook on Safety Code for Elevators and Escalators (2016) |
Available from: |
ASME |
|
Three Park Avenue |
|
New York, NY 10016-5990 |
|
(800) 843-2763 |
|
|
AMERICAN SOCIETY FOR TESTING AND MATERIALS
ASTM C55-17 |
Standard Specification for Concrete Brick (2017) |
ASTM C177-13 |
Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded Hot Plate Apparatus (2013 |
ASTM C272-16 |
Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions (2016) |
ASTM C335/C335M-17 |
Standard Test Method for Steady State Heat Transfer Properties of Horizontal Pipe Insulation (2017) |
ASTM C518-17 |
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus (2017) |
ASTM C731-15 |
Standard Test Method for Extrudability, After Package Aging, of Latex Sealants (2015) |
ASTM C732-17 |
Standard Test Method for Aging Effects of Artificial Weathering on Latex Sealants (2017) |
ASTM C836/C836M-15 |
Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course (2015) |
ASTM C1167-11 |
Standard Specification for Clay Roof Tiles(2011) |
ASTM C1371-15 |
Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers (2015) |
ASTM C1492-16
|
Standard Specification for Concrete Roof Tile (2016) |
ASTM C1549-16 |
Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer (0216) |
ASTM C1583-13 |
Standard Test Method for Tensile Strength of Concrete Surfaces and the Bond Strength or Tensile Strength of Concrete Repair and Overlay Materials by Direct Tension (Pull-off Method) (2013) |
ASTM D448-17 |
Standard Classification for Sizes of Aggrerate for Road and Bridge Construction (2017) |
ASTM D522-17 |
Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings (2017) |
ASTM D822-13 |
Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings (2013) |
ASTM D1003-13 |
Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics (2013) |
ASTM D1653-13 |
Standard Test Methods for Water Vapor Transmission of Organic Coating Films (2013) |
ASTM D1863-11 |
Standard Specification for Mineral Aggregate Used on Built-Up Roofs (2011) |
ASTM D2370-16 |
Standard Test Method for Tensile Properties of Organic Coatings (2016) |
ASTM D2824-13 |
Standard Specification for Aluminum-Pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered, and Fibered without Asbestos (2013) |
ASTM D3468-13 |
Standard Specification for Liquid-Applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing (2013) |
ASTM D3805/D3805M-16 |
Standard Guide for Application of Aluminum-Pigmented Asphalt Roof Coatings (2016) |
ASTM D4798/-16 |
Standard Test Method Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method) (2016) |
ASTM D5870-16 |
Standard Practice for Calculating Property Retention Index of Plastics (2016) |
ASTM D6694/D6694M-15 |
Standard Specification for Liquid-Applied Silicone Coating Used in Spray Polyurethane Foam Roofing (2015) |
ASTM E96-16 |
Standard Test Methods for Water Vapor Transmission of Materials (2016) |
ASTM E283-12 |
Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen (2012) |
ASTM E408-13 |
Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques (2013) |
ASTM E972-13 |
Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight (2013) |
ASTM E1918-16 |
Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped Surfaces in the Field (2016) |
ASTM E1980-11 |
Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surfaces (2011) |
ASTM E2178-13 |
Standard Test Method for Air Permeance of Building Materials (2013) |
ASTM E2357-17 |
Standard Test Method for Determining Air Leakage of Air Barrier Assemblies (2017) |
ASTM E779-10 |
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization (2010) |
ASTM E1677-11 |
Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls (2011) |
|
|
Available from: |
American Society for Testing and Materials |
|
100 Barr Harbor Drive |
|
West Conshohocken, Pennsylvania 19428-2959 |
|
(800) 262-1373 or (610) 832-9585 |
CALIFORNIA BUILDING STANDARDS COMMISSION
2019 California Plumbing Code | |
2019 California Mechanical Code | |
2019 California Building Code | |
Available from: |
California Building Standards Commission |
|
2525 Natomas Park Drive, Suite 130 |
|
Sacramento, CA 95833-2936 |
|
(916) 263-0916 |
|
|
Appliance Efficiency Regulations | |
Alternative Calculation Method (ACM) Approval Manual | |
Available from: |
California Energy Commission/Publications |
|
1516 Ninth Street |
|
Sacramento, CA 95814 |
|
(916) 654-5200 |
|
www.energy.ca.gov/title24. |
CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS
Standards for Insulating Material | |
Available from: |
California Department of Consumer Affairs |
|
Bureau of Electronic and Appliance Repair, Home Furnishings and Thermal Insulation |
|
4244 South Market Court, Suite D |
|
Sacramento, California 95834-1243 |
|
(916) 999-2041 |
COOLING TECHNOLOGY INSTITUTE
CTI ATC-105-00 |
Acceptance Test Code for Water Cooling Towers (2000) |
CTI STD-201-15 |
Standard for the Certification of Water-Cooling Tower Thermal Performance (2015) |
Available from: |
Cooling Technology Institute |
|
2611 FM 1960 West, Suite A-101 |
|
Houston, Texas 77068-3730 |
|
|
|
PO Box 73383 |
|
Houston, Texas 77273-3383 |
|
(281) 583-4087
|
COOL ROOF RATING COUNCIL
Product Rating Program Manual (2018) | |
Available from: |
Cool Roof Rating Council |
|
449 15th Street, Suite 400 |
|
Oakland, CA 94612 |
|
(866) 465-2523 |
|
www.coolroofs.org |
HYDRONICS INSTITUTE
HI Heating Boiler Standard 86, 6th Edition, (1989) | |
Available from: |
Hydronics Institute |
|
35 Russo Place, P.O. Box 218 |
|
Berkeley Heights, New Jersey 07922 |
|
(908) 464-8200 |
|
|
ILLUMINATING ENGINEERING SOCIETY
The IES Lighting Handbook, Tenth Edition (2011) | |
IES LM-79-08 |
Electrical and Photometric Measurements of Solid-State Lighting Products (2008) |
Available from: |
IES |
|
120 Wall Street, 17th Floor |
|
New York, New York 10005-4001 |
|
(212) 248-5000 |
|
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS
2007 California Mechanical Code | |
Available from: |
International Association of Plumbing and Mechanical Officials |
|
2001 E. Walnut Drive South |
|
Walnut, California 91789-2825 |
|
800 85-IAPMO (854-2766) |
|
www.iapmo.org |
|
|
INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS
2007 California Building Code | |
Available from: |
International Conference of Building Officials |
|
International Code Council Los Angeles District Office |
|
5360 South Workman Mill Road |
|
Whittier, California 90601-2298 |
|
(800) 284-4406 |
|
www.icbo.org |
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
ISO-13256-1
ISO-13256-2 |
Water-Source Heat Pumps - Testing and Rating for Performance - Part 1: Water-to-Air and Brine-to-Air Heat Pumps (1998) "Water-source heat pumps --Testing and rating for performance -- Part 1: Water-to-water and brine-to-water heat pumps," (1998) |
Available from: |
ISO |
|
1, rue de Varembe |
|
Case postale 56 |
|
CH-1211 |
|
Geneve 20, Switzerland
|
international window film association
Visual Quality Standard for Applied Window Film |
Visual Quality Standard for Applied Window Film (Re-endorsed 2015)
|
Available from: |
International Window film Association P.O. Box 3871 Martinsville, VA 24115-3871 276-666-4932 |
|
|
|
|
|
|
|
|
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEMA SSL 7A-2015 |
“Phase Cut Dimming for Solid State Lighting: Basic Compatibility” |
Available from: |
1300 North 17th Street, Suite 1752 |
|
Rosslyn, VA 22209 |
|
703-841-3200 |
|
www.nema.org |
NATIONAL FENESTRATION RATING COUNCIL
Procedures for Determining Fenestration Product U-factors (2017) | |
NFRC 200 |
Procedures for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence (2017) |
NFRC 202 |
Procedure for Determining Translucent Fenestration Product Visible Transmittance at Normal Incidence (2017) Note: This Technical document has yet not been fully approved by NFRC. If this document is not approved before the Building Energy Standards effective date it will be removed. |
NFRC 203 |
Procedure for Determining Visible Transmittance of Tubular Daylighting Devices (2017) Note: This Technical document has yet not been fully approved by NFRC. If this document is not approved before the Building Energy Standards effective date it will be removed. |
NFRC 400 |
Procedures for Determining Fenestration Product Air Leakage (2017) |
Available from: |
National Fenestration Rating Council |
|
6035 Ivy Lane, Suite 140 Greenbelt, MD 20770. |
|
|
|
(301) 589-1776 |
|
WWW.NFRC.org and Email: info@nfrc.org |
NSF INTERNATIONAL (formerly National Sanitation Foundation)
NSF/ANSI 50 2016 |
Circulation System Components and Related Materials for Swimming Pools, Spas/Hot Tubs (2016) |
Available from: |
NSF International |
|
PO Box 130140 |
|
Ann Arbor, MI 48113 |
|
(734) 769-8010
|
Residential Energy Services network
ANSI/RESNET/ICC 380-2016 |
Standard for Testing Airtightness of Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems (2016) |
Available from: |
Residential Energy Services Network, Inc. (RESNET) |
|
P.O. Box 4561 |
|
Oceanside, CA 92052-4561 |
|
SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION
Residential Comfort System Installation Standards (2016) | |
Available from: |
Sheet Metal And Air Conditioning Contractors National Association (SMACNA) |
|
4201 Lafayette Center Drive |
|
Chantilly, VA 20151-1209 |
|
(703) 803-2980 |
|
www.smacna.org |
UNDERWRITERS LABORATORIES
Standard for Safety for Factory-made Air Ducts and Connectors (2017) | |
UL 181A |
Standard for Safety for Closure Systems for Use with Rigid Air Ducts and Air Connectors (2017) |
UL 181B |
Standard for Safety for Closure Systems for Use with Flexible Air Ducts and Air Connectors (2017) |
UL 723 |
Standard for Test for Surface Burning Characteristics of Building Materials (2017) |
UL 727 |
Standard for Oil-Fired Central Furnaces (2006) |
UL 731 |
Standard for Oil-Fired Unit Heaters (2012) |
UL 1077 |
Standard for Supplementary Protectors for Use in Electrical Equipment (2015) |
UL 1574 |
Track Lighting Systems (2016) |
UL 1741
UL 1973 UL 8750 |
Standard for Luminaires (2012) Standard for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources (2018) Standard for Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications (2018) Low Voltage Lighting Systems (2018) Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products (2018) |
UL 9540 |
Standard for Energy Storage Systems and Equipment (2016) |
Available from: |
Underwriters Laboratories |
|
333 Pfingsten Road |
|
Northbrook, Illinois 60062-2096 |
|
(847) 272-8800 |