For all systems where reporting of flicker is required, the test data shall be submitted to the California Energy Commission in the format specified in Table JA-10. For two years from the date of certification, the entity submitting the test report shall keep all documentation required for compliance, stored and shall provide copies of this documentation to the Energy Commission within 10 days of written request received from the Commission. This documentation shall also include for each measured system, a digital file containing the raw photometric data as described in Section JA10.5.
|
Data |
Units/Format |
|
Test Date |
|
|
Test Operator |
Company Name, Contact Name, Address, Phone Number, e-mail address |
|
Entity submitting results |
Company Name, Contact Name, Address, Phone Number, e-mail address |
|
|
Manufacturer or Brand |
|
Dimmer type,Manufacturer or Brand, model number | |
|
Tested lighting system component: light source (lamp or light engine) |
Light source type (lamp, light engine, etc), Manufacturer or Brand, model number |
|
Tested lighting system component: Ballast or Driver |
Ballast or Driver, Manufacturer or Brand, model number |
|
Recording interval |
seconds (no greater than 0.00005 seconds) |
|
Equipment Measurement Period |
seconds (no less than 1 second) |
|
Fraction of rated light output integrated over measurement period at 100%, 20% and minimum fraction of light output. |
Fraction of rated light output integrated over measurement period at 100%, 20% and minimum fraction of light output. |
|
Amplitude modulation unfiltered |
calculated percent amplitude modulation unfiltered for each dimming level (100%, 20% and minimum fraction of light output) |
|
Percent amplitude modulation with 1,000 Hz cut-off |
calculated percent amplitude modulation, data filtered with a 1,000 Hz cut-off frequency for each dimming level: (100%, 20%, and minimum fraction of light output) |
|
Percent amplitude modulation with 400 Hz cut-off |
calculated percent amplitude modulation, data filtered with a 400 Hz cut-off frequency for each dimming level: (100%, 20%, and minimum fraction of light output) |
|
Percent amplitude modulation with 200 Hz cut-off |
calculated percent amplitude modulation, data filtered with a 200 Hz cut-off frequency for each dimming level: (100%, 20% and minimum fraction of light output) |
|
Percent amplitude modulation with 90 Hz cut-off |
calculated percent amplitude modulation, data filtered with a 90 Hz cut-off frequency for each dimming level: (100%, 20% and minimum fraction of light output) |
|
Percent amplitude modulation with 40 Hz cut-off |
calculated percent amplitude modulation, data filtered with a 40 Hz cut-off frequency for each dimming level: (100%, 20% and minimum fraction of light output) |