NA8.1 Luminaire Power

The following tables contain a limited list of lamp and ballast combinations. These tables provide an alternate voluntary option to the provision in Section 130(c) for determining luminaire power for any lamp and ballast combination specifically listed in Appendix NA8. This appendix is not intended to list all possible lamp and ballast combinations, and shall not to be used to determine luminaire power for any lighting system not specifically listed in this appendix.

Table NA8-1 – Fluorescent U-Tubes

Type

Lamps -

Number

Lamps -

Designation

Ballasts -

Number

Ballasts -

Designation

Ballasts -

Description

System Watts

2 ft. Fluorescent U-Tube T8

1

FB31T8/F32T8U

1

ELECT NO

Electronic Normal Output

39

2 ft. Fluorescent U-Tube T8

2

FB31T8/F32T8U

1

ELECT NO

Electronic Normal Output

62

2 ft. Fluorescent U-Tube T8

3

FB31T8/F32T8U

1

ELECT NO

Electronic Normal Output

92

2 ft. Fluorescent U-Tube T8

1

FB31T8/F32T8U

1

ELECT DIM

Electronic Dimming

33

2 ft. Fluorescent U-Tube T8

2

FB31T8/F32T8U

1

ELECT DIM

Electronic Dimming

64

2 ft. Fluorescent U-Tube T8

3

FB31T8/F32T8U

1

ELECT DIM

Electronic Dimming

93

2 ft. Fluorescent U-Tube T8

4

FB31T8/F32T8U

1

ELECT DIM

Electronic Dimming

116

NO = ballast factor 85 to 100%

 

Table NA8-2 – Fluorescent Linear Lamps T5 

Type

Lamps -

Number

Lamps

Designation

Ballasts -

Number

Ballasts -

Designation

Ballasts -

Description

System Watts

~23” Fluorescent Program Start T5 (14W)

1

F14T5

1

ELECT

Elect. Program Start BF=1

18

~23” Fluorescent Program Start T5 (14W)

2

F14T5

1

ELECT

Elect. Program Start BF=1

34

~34.5” Fluorescent Program Start T5 (21W)

1

F21T5

1

ELECT

Elect. Program Start BF=1

27

~34.5” Fluorescent Program Start T5 (21W)

2

F21T5

1

ELECT

Elect. Program Start BF=1

50

~46” Fluorescent Program Start T5 (28W)

1

F28T5

1

ELECT

Elect. Program Start BF=1

30

~46” Fluorescent Program Start T5 (28W)

2

F28T5

1

ELECT

Elect. Program Start BF=1

60

~58.5” Fluorescent Program Start T5 (35W)

1

F35T5

1

ELECT

Elect. Program Start BF=1

40

~58.5” Fluorescent Program Start T5 (35W)

2

F35T5

1

ELECT

Elect. Program Start BF=1

78

~23” Fluorescent Program Start T5 High Output (24W)

1

F24T5HO

1

ELECT

Elect. Program Start BF=1

29

~23” Fluorescent Program Start T5 High Output (24W)

2

F24T5HO

1

ELECT

Elect. Program Start BF=1

55

~34.5” Fluorescent Program Start T5 High Output(39W)

1

F39T5

1

ELECT

Elect. Program Start BF=1

43

~34.5” Fluorescent Program Start T5 High Output(39W)

2

F39T5

1

ELECT

Elect. Program Start BF=1

85

~46” Fluorescent Program Start T5 High Output (54W)

1

F54T5

1

ELECT

Elect. Program Start BF=1

62

~46” Fluorescent Program Start T5 High Output (54W)

2

F54T5

1

ELECT

Elect. Program Start BF=1

121

~46” Fluorescent Program Start T5 High Output (54W)

1

F54T5

1

ELECT DIM

Elect. Dimming

63

~46” Fluorescent Program Start T5 High Output (54W)

2

F54T5

1

ELECT DIM

Elect. Dimming

125

~57.5” Fluorescent Program Start T5 High Output (80W)

1

ºF80T5

1

ELECT

Elect. Program Start BF=1

90

Table NA8-3 – Fluorescent Rapid Start T-8

Type

Lamps

Num-ber

Lamps

Desig-nation

Ballasts

Num-ber

Ballasts

Desig-nation

Ballasts

Descrip-tion

System Watts

2 foot Fluorescent Rapid Start T8 (17W)

Electronic Ballasts

1

F17T8

1

ELECT NO

Electronic Normal Output

22

2 foot Fluorescent Rapid Start T8 (17W)

Electronic Ballasts

2

F17T8

1

ELECT NO

Electronic Normal Output

33

2 foot Fluorescent Rapid Start T8 (17W)

Electronic Ballasts

3

F17T8

1

ELECT NO

Electronic Normal Output

53

2 foot Fluorescent Rapid Start T8 (17W)

Electronic Ballasts

3

F17T8

2

ELECT NO

Electronic Normal Output

55

2 foot Fluorescent Rapid Start T8 (17W)

Electronic Ballasts

4

F17T8

1

ELECT NO

Electronic Normal Output

63

2 foot Fluorescent Rapid Start T8 (17W)

1

F17T8

1

ELECT DIM

Electronic Dimming

20

2 foot Fluorescent Rapid Start T8 (17W)

2

F17T8

1

ELECT DIM

Electronic Dimming

37

2 foot Fluorescent Rapid Start T8 (17W)

3

F17T8

1

ELECT DIM

Electronic Dimming

56

2 foot Fluorescent Rapid Start T8 (17W)

4

F17T8

1

ELECT DIM

Electronic Dimming

69

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

1

F25T8

1

ELECT NO

Electronic Normal Output

27

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

2

F25T8

1

ELECT NO

Electronic Normal Output

48

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

3

F25T8

1

ELECT NO

Electronic Normal Output

68

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

4

F25T8

1

ELECT NO

Electronic Normal Output

89

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

1

F25T8

1

ELECT RO

Electronic Reduced Output

24

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

2

F25T8

1

ELECT RO

Electronic Reduced Output

41

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

3

F25T8

1

ELECT RO

Electronic Reduced Output

59

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

4

F25T8

1

ELECT RO

Electronic Reduced Output

76

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

1

F25T8

1

ELECT HO

Electronic High Output

29

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

2

F25T8

1

ELECT HO

Electronic High Output

51

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

3

F25T8

1

ELECT HO

Electronic High Output

74

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

1

F25T8

1

ELECT DIM

Electronic Dimming

25

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

2

F25T8

1

ELECT DIM

Electronic Dimming

49

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

3

F25T8

1

ELECT DIM

Electronic Dimming

76

3 foot Fluorescent Rapid Start T8 (25W)

Electronic Ballasts

4

F25T8

1

ELECT DIM

Electronic Dimming

96

 

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

1

F32T8/30ES

1

ELECT NO

Electronic Normal Output

29

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

2

F32T8/30ES

1

ELECT NO

Electronic Normal Output

54

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

3

F32T8/30ES

1

ELECT NO

Electronic Normal Output

79

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

4

F32T8/30ES

1

ELECT NO

Electronic Normal Output

104

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

1

F32T8/30ES

1

ELECT RO

Electronic Reduced Output

27

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

2

F32T8/30ES

1

ELECT RO

Electronic Reduced Output

48

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

3

F32T8/30ES

1

ELECT RO

Electronic Reduced Output

70

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

4

F32T8/30ES

1

ELECT RO

Electronic Reduced Output

91

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

1

F32T8/30ES

1

ELECT NO EE

EE Normal Output

33

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

2

F32T8/30ES

1

ELECT NO EE

Energy efficiency Normal Output

52

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

3

F32T8/30ES

1

ELECT NO EE

Energy efficiency Normal Output

77

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

4

F32T8/30ES

1

ELECT NO EE

Energy efficiency Normal Output

101

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

1

F32T8/30ES

1

ELECT RO EE

EE Reduced Output

28

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

2

F32T8/30ES

1

ELECT RO EE

EE Reduced Output

45

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

3

F32T8/30ES

1

ELECT RO EE

EE Reduced Output

66

4 foot Fluorescent Instant Start T8 (“Energy Saving” 30W)

4

F32T8/30ES

1

ELECT RO EE

EE Reduced Output

88

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

ELECT NO

Electronic Normal Output

32

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT NO

Electronic Normal Output

62

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

ELECT NO

Electronic Normal Output

93

4 foot Fluorescent Rapid Start T8 (32W)

4

F32T8

1

ELECT NO

Electronic Normal Output

114

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

EE NO

EE Normal Output

35

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

EE NO

EE Normal Output

55

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

EE NO

EE Normal Output

82

4 foot Fluorescent Rapid Start T8 (32W)

4

F32T8

1

EE NO

EE Normal Output

107

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

ELECT RO

Electronic Reduced Output

29

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT RO

Electronic Reduced Output

51

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

ELECT RO

Electronic Reduced Output

76

4 foot Fluorescent Rapid Start T8 (32W)

4

F32T8

1

ELECT RO

Electronic Reduced Output

98

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT HO

Electronic High Output

77

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

ELECT HO

Electronic High Output

112

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

EE RO

EE Reduced Output

30

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

EE RO

EE Reduced Output

48

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

EE RO

EE Reduced Output

73

4 foot Fluorescent Rapid Start T8 (32W)

4

F32T8

1

EE RO

EE Reduced Output

96

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT TL

Electronic Two Level (50 & 100%)

65

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

ELECT DIM1

Electronic Dimming

35

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT DIM1

Electronic Dimming

68

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

ELECT DIM1

Electronic Dimming

102

4 foot Fluorescent Rapid Start T8 (32W)

1

F32T8

1

ELECT DIM2

Electronic Dimming

33

4 foot Fluorescent Rapid Start T8 (32W)

2

F32T8

1

ELECT DIM2

Electronic Dimming

64

4 foot Fluorescent Rapid Start T8 (32W)

3

F32T8

1

ELECT DIM2

Electronic Dimming

93

4 foot Fluorescent Rapid Start T8 (32W)

4

F32T8

1

ELECT DIM2

Electronic Dimming

116

5 foot Fluorescent Rapid Start T8 (40W)

1

F40T8

1

ELECT

Electronic

46

5 foot Fluorescent Rapid Start T8 (40W)

2

F40T8

1

ELECT

Electronic

79

5 foot Fluorescent Rapid Start T8 (40W)

3

F40T8

1

ELECT

Electronic

112

RO = ballast factor 70 to 85%      NO = ballast factor 85 to 100%        HO = ballast factor >100%

Table NA8-4 – Fluorescent Rapid Start High Output (HO) T8, 8 ft

Type

Lamps -

Number

Lamps -

Designation

Ballasts -

Number

Ballasts -

Designation

Ballasts -

Description

System Watts

8 foot Fluorescent Rapid Start T8 High Output (86W)

1

F96T8/HO

1

ELECT

Electronic

88

8 foot Fluorescent Rapid Start T8 High Output (86W)

2

F96T8/HO

1

ELECT

Electronic

160

HO = ballast factor >100%

Table NA8-5 – High Intensity Discharge

Type

Lamps -

Number

Lamps -

Designation

Ballasts

Number

Ballasts -

Designation

Ballasts -

Description

System Watts

Comment

Metal Halide

1

M35/39

1

MAG STD

Mag. Stand.

58

 

Metal Halide

1

M35/39

1

ELECT

Electronic

44

 

Metal Halide

1

M50

1

MAG STD

Mag. Stand.

67

 

Metal Halide

1

M50

1

ELECT

Electronic

58

 

Metal Halide

1

M70

1

MAG STD

Mag. Stand.

95

 

Metal Halide

1

M70

1

ELECT

Electronic

86

 

Metal Halide

1

M100

1

MAG STD

Mag. Stand.

130

 

Metal Halide

1

M100

1

ELECT

Electronic

110

 

Metal Halide

1

M150

1

MAG STD

Mag. Stand.

185

 

Metal Halide

1

M150

1

ELECT

Electronic

168

 

Metal Halide

1

M175

1

MAG STD

Mag. Stand.

208

 

Metal Halide

1

M175

1

ELECT

Electronic

194

 

Metal Halide

1

M200

1

MAG STD

Mag. Stand.

232

 

Metal Halide

1

M250

1

MAG STD

Mag. Stand.

295

 

Metal Halide

1

M250

1

ELECT

Electronic

269

 

Metal Halide

1

M320

1

MAG STD

Mag. Stand.

368

 

Metal Halide

1

M320

1

ELECT

Electronic

343

 

Metal Halide

1

M360

1

MAG STD

Mag. Stand.

422

 

Metal Halide

1

M400

1

MAG STD

Mag. Stand.

452

 

Metal Halide

1

M400

1

ELECT

Electronic

430

 

Metal Halide

1

M450

1

MAG STD

Mag. Stand.

508

 

Metal Halide

1

M750

1

MAG STD

Mag. Stand.

818

 

Metal Halide

1

M1000

1

MAG STD

Mag. Stand.

1080

 

Metal Halide

1

M1500

1

MAG STD

Mag. Stand.

1605

 

High Pressure Sodium

1

S35

1

MAG STD

Mag. Stand.

47

 

High Pressure Sodium

1

S50

1

MAG STD

Mag. Stand.

66

 

High Pressure Sodium

1

S70

1

MAG STD

Mag. Stand.

91

 

High Pressure Sodium

1

S100

1

MAG STD

Mag. Stand.

128

 

High Pressure Sodium

1

S150

1

MAG STD

Mag. Stand.

188

 

High Pressure Sodium

1

S200

1

MAG STD

Mag. Stand.

230

 

High Pressure Sodium

1

S250

1

MAG STD

Mag. Stand.

295

 

High Pressure Sodium

1

S400

1

MAG STD

Mag. Stand.

464

 

High Pressure Sodium

1

S1000

1

MAG STD

Mag. Stand.

1100

 

 

Table NA8-6 –12 Volt Tungsten Halogen Lamps Including MR16, Bi-pin, AR70, AR111, PAR36
(Shall NOT apply to track lighting systems)

Type

Lamps -

Number

Lamps -

Designation

Ballasts -

Number

Ballasts -

Designation

Ballasts -

Description

System Watts

Comment

High Pressure Sodium

1

20 watt lamp

1

ELECT

Electronic Power Supply

23

 

High Pressure Sodium

1

25 watt lamp

1

ELECT

Electronic Power Supply

28

 

High Pressure Sodium

1

35 watt lamp

1

ELECT

Electronic Power Supply

38

 

High Pressure Sodium

1

37 watt lamp

1

ELECT

Electronic Power Supply

41

 

High Pressure Sodium

1

42 watt lamp

1

ELECT

Electronic Power Supply

45

 

High Pressure Sodium

1

50 watt lamp

1

ELECT

Electronic Power Supply

54

 

High Pressure Sodium

1

65 watt lamp

1

ELECT

Electronic Power Supply

69

 

High Pressure Sodium

1

71 watt lamp

1

ELECT

Electronic Power Supply

75

 

High Pressure Sodium

1

75 watt lamp

1

ELECT

Electronic Power Supply

80

 

High Pressure Sodium

1

20 watt lamp

1

MAG

Mag. Transformer

24

 

High Pressure Sodium

1

25 watt lamp

1

MAG

Mag. Transformer

29

 

High Pressure Sodium

1

35 watt lamp

1

MAG

Mag. Transformer

39

 

High Pressure Sodium

1

37 watt lamp

1

MAG

Mag. Transformer

42

 

High Pressure Sodium

1

42 watt lamp

1

MAG

Mag. Transformer

46

 

High Pressure Sodium

1

50 watt lamp

1

MAG

Mag. Transformer

55

 

High Pressure Sodium

1

65 watt lamp

1

MAG

Mag. Transformer

70

 

High Pressure Sodium

1

71 watt lamp

1

MAG

Mag. Transformer

76

 

High Pressure Sodium

1

75 watt lamp

1

MAG

Mag. Transformer

81