2016 Residential Compliance Documents – Change Notes
CF1R-NCB-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-NCB-01-E-PrescriptiveNewlyConstructedBuilding.pdf
• Inserted a new Section/Table F. – “Roof/Ceiling Insulation”
• Deleted Section G. – “Radiant Barrier”
• Updated minimum required HVAC efficiencies:
o AFUE = 81%
o HSPF = 8.0
o SEER = 14
• Updated required airflow rate
o CFM per ft2
• Updated minimum required net free vent area
o 1 ft2 per 750 CFM
CF1R-ADD-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-ADD-01-E-PrescriptiveAdditionsBuilding.pdf
•
Sections B & C – inserted note at the bottom of the table
o “Note: Where insulation is
installed above the roofing membrane, or above the layer used to seal the roof from water
penetration, the insulation shall have a maximum water absorption of 0.3 percent
by volume when tested according to ASTM Standard C272.”
CF1R-ADD-02
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/Alterrations_and_Additions_Paper_Forms/2016-CF1R-ADD-02-E-PresAdditions-SimpleNonHERS-PaperVersion.pdf
•
Sections B & C – inserted note at the bottom of the
table
o “Note: Where insulation is
installed above the roofing membrane, or above the layer used to seal the roof from water
penetration, the insulation shall have a maximum water absorption of 0.3 percent
by volume when tested according to ASTM Standard C272.”
CF1R-ALT-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-ALT-01-E-PrescriptiveAlterationsBuilding.pdf
•
Sections B & C – inserted note at the bottom of the table
o “Note: Where insulation is
installed above the roofing membrane, or above the layer used to seal the roof from water
penetration, the insulation shall have a maximum water absorption of 0.3 percent
by volume when tested according to ASTM Standard C272.”
CF2R-ALT-02
•
Updated minimum required HVAC efficiency:
o AFUE = 81%
o HSPF = 8.0
o SEER = 14
CF1R-ALT-03/04
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-ALT-03-E-PaperVersionOfALT-HVAC-CZ%201,3-7,16.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-ALT-04-E-PaperVersionOfALT-HVAC-CZ%202,8-15.pdf
• Updated minimum required Lineset R-value
o ≥ R-2.8
• Removed all references to “Plenums”
CF1R-ALT-05
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/Alterrations_and_Additions_Paper_Forms/2016-CF1R-ALT-05-E-PrescriptiveAlterations-SimpleNonHERS-PaperVersion.pdf
•
Section B – inserted note at the bottom of the table
“Note: Where
insulation is installed above the roofing membrane or above the layer used to
seal the roof from
water penetration, the insulation shall have a maximum water absorption of 0.3
percent by volume when tested according to ASTM Standard C272.”
CF1R-SRA-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF1R/2016-CF1R-SRA-01-E-SolarReadyBuildings.pdf
•
Section F. – revised Section name: “Smart Thermostats and
Alternative Efficiency Measure”
•
F01 – revised static text
o “All thermostats comply with
Reference Joint Appendix JA5 and are capable of receiving and responding to Demand
Response Signals prior to granting of an occupancy permit by the enforcing
agency.”
•
F02 – inserted new F02: “Alternative Efficiency Measure”
o User selects one from list:
§ Install a dishwasher that meets or
exceeds ENERGY STAR Program requirements with either a refrigerator that meets
or exceeds the ENERGY STAR Program requirements or a whole house fan driven by
an electronically commutated motor; or
§ Install a home automation system capable
of, at a minimum, controlling the appliances and lighting of the dwelling and
responding to demand response signals; or
§ Install alternative plumbing piping to
permit the discharge from the clothes washer and all showers and bathtubs to be
used for an irrigation system in compliance with the California Plumbing Code
and any applicable local ordinances; or
§ Install a rainwater catchment system
designed to comply with the California Plumbing Code and any applicable
local ordinances, and that uses rainwater flowing from at least 65% of the
available roof area
CF2R-ADD-02
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/Alterrations_and_Additions_Paper_Forms/2016-CF2R-ADD-02-E-PrescriptiveAdditions-SimpleNonHERS-PaperVersion.pdf
•
Sections B – inserted note at the bottom of the table
o “Note: Where insulation is
installed above the roofing membrane or above the layer used to seal the roof from water
penetration, the insulation shall have a maximum water absorption of 0.3 percent
by volume when tested according to ASTM Standard C272.”
•
Deleted “Kitchen Lighting Requirements”
•
Deleted Section Q. – “Installed Kitchen Lighting Compliance”
•
Deleted “Kitchen Lighting Requirements Worksheet”
CF2R-ALT-05
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/Alterrations_and_Additions_Paper_Forms/2016-CF2R-ALT-05-E-PrescriptiveAlterations-SimpleNonHERS-PaperVersion.pdf
•
Inserted new A14 – “Exceptions to Minimum Aged Solar
Reflectance and Minimum Thermal Emittance or SRI”
•
Sections B – inserted note at the bottom of the table
o “Note: Where insulation is
installed above the roofing membrane or above the layer used to seal the roof from water
penetration, the insulation shall have a maximum water absorption of 0.3 percent
by volume when tested according to ASTM Standard C272.”
•
Deleted “Kitchen Lighting Requirements”
•
Deleted Section Q. – “Installed Kitchen Lighting Compliance”
•
Deleted “Kitchen Lighting Requirements Worksheet”
CF2R-ENV-03
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-ENV-03-InsulationInstallation.pdf
•
G08 – updated R-value
o R-22
•
G09 – revised static text
o “Vapor Retarder – 150.0(g)1:
In Climate
Zones 14 through 16, the earth floor of unvented crawl space shall be covered with a
Class I or Class II vapor retarder. This requirement shall also apply to
controlled ventilation crawl space for buildings complying with the Exception to
Section 150.0(d).”
•
G10 – revised static text”
o “Vapor Retarder – 150.2(g)2:
In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be
installed on the conditioned side of all insulation in all exterior walls,
vented attics and unvented attics with air-permeable insulation.”
•
Deleted G11
CF2R-LTG-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-LTG-01-E-Lighting–SingleFamilyDwellings.pdf
•
Completely revised from 2013
CF2R-MCH-01a,b,c
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-01a-SpaceConditioningSystem-Performance.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-01b-SpaceConditioningSystem-PrescriptiveAlterations.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-01c-SpaceConditioningSystem-PrescriptiveNCB.pdf
•
Inserted new N09/K09/M09
o “Liquid Line Filter Drier: If
applicable, a liquid line filter drier shall be installed according to the
manufacturer’s specifications. Section 150.0(h)3B.”
CF2R-MCH-02
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-02-WholeHouseFan.pdf
•
Updated required airflow rate
o CFM per ft2
•
Updated minimum required net free vent area
o 1 ft2 per 750 CFM
CF2R/3R-MCH-20a,d
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-20a-DuctLeakageTest-NewConst.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-20d-DuctLeakageTest-ExistingConst.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-20a-DuctLeakageTest-NewConst.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-20d-DuctLeakageTest-ExistingConst.pdf
•
Updated “New/Complete Replacement” Duct Leakage Factor: 5%
CF2R/3R-MCH-21
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-21-DuctLocation.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-21-DuctLocation.pdf
•
Removed all references to “Supply”
CF2R/3R-MCH-25a,b,c,d,e
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-25a-RefrigerantCharge-Superheat.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-25b-RefrigerantCharge-Subcooling.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-25c-RefrigerantCharge-WeighIn.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-25e-RefrigerantCharge-WinterSetup.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-25a-RefrigerantCharge-Superheat.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-25b-RefrigerantCharge-Subcooling.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-25c-RefrigerantCharge-WeighinObservation.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-25d-RefrigerantCharge-FID.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-25e-RefrigerantCharge-WinterSetUp.pdf
•
Replaced “Charge Indicator Display (CID)” with “Fault Indicator
Display (FID)”
•
Inserted new A09: “Liquid Line Filter Drier Installed According to
Manufacturer’s Specifications (if applicable)”
o User selects from list:
Yes; or
NA
CF2R/3R-MCH-25f
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-25f-RefrigerantCharge-PackagedSystemManufacturerCert.pdf
•
Replaced “Charge Indicator Display (CID)” with “Fault Indicator
Display (FID)”
•
Inserted new A09: “Liquid Line Filter Drier Installed According to
Manufacturer’s Specifications (if applicable)”
o User selects from list:
§ Yes; or
§ NA
•
Captured new role of installer
o Deleted D01
CF2R/3R-MCH-26
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-26-RatedSystemVerification.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-26-RatedSystemVerification.pdf
•
Updated to capture approved directories:
o CEC
o DOE
o AHRI
CF2R/3R-MCH-28
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-MCH-28-ReturnDuctAndFilterGrilleDesign-Table150.0-BorC.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-MCH-28-ReturnDuctAndFilterGrilleDesign-Table150.0-BorC.pdf
•
Revised static text: Table 150.0-B/C
CF2R-PLB-02
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-PLB-02-NonHERS-SingleDwellingUnitHotWaterSystemDistribution.pdf
•
Inserted a new Section I. – “Point of Use”
CF2R/3R-PLB-22
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-PLB-22-HERS-SingleDwellingUnitHotWaterSystemDistribution.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-PLB-22-HERS-SingleDwellingUnitHotWaterSystemDistribution.pdf
•
Deleted Section I. – “HERS-Verified Point of Use Requirements”
CF2R-SPV-01a,c
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-SPV-01a-PVSystems-ComplianceCredits.pdf
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-SPV-01c-PvComplianceCreditsAndExemptionsToSRA.pdf
•
Deleted Section B. – “PV System Eligibility for Compliance Credit: NSHP
Program Participant”
•
Removed references to NSHP Program
CF2R-SPV-01b
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-SPV-01b-PVSystemsExceptionsToSRA_Requirements.pdf
•
Removed references to NSHP Program
CF2R-STH-01
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF2R/2016-CF2R-STH-01-SolarWaterHeatingSystems.pdf
•
Deleted Section E. – “Sizing Compliance with Prescriptive Electric Water
Heating Requirement”
CF3R-ENV-21
http://www.energy.ca.gov/2015publications/CEC-400-2015-032/appendices/forms/CF3R/2016-CF3R-ENV-21-HERS-QII-FramingStage-Batt,Loose,Fill,SPF.pdf
•
C13 – revised static text
o “All single-member window and door headers shall be
insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a
minimum of R-5 for all other assemblies. Insulation is to be placed between the
interior face of the header and inside surface of the interior wall finish.”