5.5 Performance Approach Compliance for Water Heating
5.5.1 Energy Budget Calculation

When the performance compliance method is used, the water heating energy budget is based on the performance of a heat pump water heater in most climate zones. In addition to a heat pump water heater, a compact hot water distribution system is required in climate zone 1 and 16 and a drain water heat recovery device also is required in climate zone 16. The water heating energy budget in climate zones 3, 4, 13, or 14, is based on the performance of a gas instantaneous water heater. Both gas and electric water heaters used in the standard design meet the minimum requirements in California’s Title 20 Appliance Efficiency Regulations Section 1605.1(f) for federally regulated appliances

The computer performance approach allows for the modeling of water heating system performance by taking into account building characteristics, climate, system type, efficiency, and fuel type. The standard design water heating budget is defined by the corresponding prescriptive requirements. The performance method allows for modeling alternative water heater and distribution system combinations. Some of these options will offer compliance credits, and others will result in penalties.

5.5.2 Systems Serving a Single Dwelling Unit

In the case of single dwelling units, any type or number of water heaters supported by the software can be installed. The calculated energy use of the proposed design is compared to the standard design energy budget based on either a single gas instantaneous water heater with a standard distribution system for gas water heaters, or a HPWH with compact distribution system and drain water heat recovery for electric water heaters. Adding multiple water heaters to a single-family design will generally result in an energy penalty in the water heating budget that must be offset elsewhere in the total energy budget.

A standard distribution system serving a single dwelling unit does not incorporate a pump for hot water recirculation and does not take credit for any additional DHW design features. All mandatory pipe insulation requirements must be met, such as insulating all hot water pipes. Alternative distribution systems are compared to the standard design case by using distribution system multipliers (DSMs), which effectively rate alternative options.

Table 5-9 lists all the recognized distribution systems that can be used in the performance approach with the assigned distribution multiplier. The standard distribution system has a multiplier of 1.0. Distribution systems with a multiplier less than 1 represent an energy credit, while distribution systems with a multiplier greater than 1 are counted as an energy penalty. For example, pipe Insulation with HERS Inspection Required (PIC-H) has a multiplier of 0.8. That means that it is modeled at 20 percent less distribution loss than the standard distribution system. For more information or installation requirements on any of the systems, refer to Section 5.6.

​​​​​Table 5-9: Applicability of Distribution Systems Options Within a Dwelling Unit
Distribution System Types
Assigned Distribution System Multiplier
Systems Serving a Single Dwelling Unit
No HERS Inspection Required
Trunk and Branch -Standard (STD)
1.0
Yes
No HERS Inspection Required
Compact Design – Basic (CHWDS)
0.7
Yes
No HERS Inspection Required
Parallel Piping (PP)
1.1
Yes
No HERS Inspection Required
Point of Use (POU)
0.3
Yes
No HERS Inspection Required Recirculation: Non-Demand Control Options (R-ND)
9.8
Yes
No HERS Inspection Required Recirculation with Manual Demand Control (R-Dman)
1.75
Yes
No HERS Inspection Required Recirculation with Motion Sensor Demand Control (R-DAuto)
2.6
Yes
HERS Inspection Required
Pipe Insulation (PIC-H)
0.85
Yes
HERS Inspection Required
Parallel Piping with 5’ maximum length (PP-H)
1
Yes
HERS Inspection Required
Compact Design - Expanded (CHWDS-H)
0.3 – 0.7 1
Yes
HERS Inspection Required
Recirculation with Manual Demand Control (R-Drmc-H)
1.6
Yes
HERS Inspection Required
Recirculation with Motion Sensor Demand Control (RDRsc-H)
2.4
Yes

1. The multiplier for the Compact Design – Expanded credit varies depending on the home’s floorplan and water heater location. See Section 5.6.2.4 for more information.

5.5.3 Treatment of Water Heater Efficiency

For information on how water heater efficiency is considered in terms of modeling energy performance using the compliance software tool, please refer to the Residential Alternative Calculation Method (ACM) Reference Manual.

5.5.4 Compliance Issues

Water heating is becoming more important to overall building compliance as building envelope performance and mechanical efficiency improve. When the performance approach is used, a high-efficiency water heater and an efficient distribution system can significantly affect the overall performance margin of a building, especially in the milder climates like Climate Zones 4 through 9, where water heating typically represents a larger fraction of the overall energy budget.

Asking for a cut sheet on the installed equipment to verify efficiency is a simple shortcut to checking compliance. When used in a combined hydronic system, it is important to check the capacity of the system to verify that both space and water heating loads can be met.

This panel displays referenced content when certain links are clicked.

This website and the messages contained in its webpages are funded by customers unless otherwise noted.
This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2026 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.