F1.2 Summary of Requirements

Prescriptive compliance approach –

  1. Zonally controlled systems are not required, but if installed must meet mandatory airflow and fan efficacy requirements using slightly different test methods than for single speed and variable speed compressors.
  2. Bypass ducts/dampers are not allowed.

Performance compliance approach –

  1. Zonally controlled systems must be modeled then installed.
  2. Bypass dampers are allowed only if modeled and indicated on the CF1R.
  3. Dual speed/multi speed condensers may also qualify for a credit (at reduced penalty) and if modeled, must be installed.

Note: when a feature is “modeled” using the performance compliance approach it will appear on the certificate of compliance.

This panel displays referenced content when certain links are clicked.

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2024 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.