6.2 Scope, Approach, and Applications

This chapter applies to all nonresidential outdoor lighting, whether attached to buildings, poles, structures or self-supporting, including, but not limited to, lighting for hardscape areas such as parking lots, lighting for building entrances, lighting for all outdoor sales areas, and lighting for building façades.

The nonresidential outdoor lighting part of the Energy Code includes minimum control requirements, maximum allowable lighting power, and shielding (uplight and glare) zonal lumen limits for outdoor luminaires.

All section (§) and table references in this chapter refer to sections and tables contained in the Energy Code.

Refer to Residential Compliance Manual Chapter 6 for information on lighting requirements for single-family residential buildings.

Refer to Nonresidential Compliance Manual Chapter 14 for information on lighting requirements for multifamily buildings.

6.2.1 Outdoor Lighting Power Compliance Approach

Outdoor lighting power densities are structured using a layered lighting approach. With the layered approach, the first layer of allowed lighting power is general hardscape for the entire site. After the allowed lighting power has been determined for this first layer, additional layers of lighting power are allowed for specific applications when they occur on the site. For example, the total allowed power for a sales lot with frontage is determined by layering the general hardscape, outdoor sales lot, and outdoor sales lot frontage allowances, with specific restrictions associated with the location of the power used for frontage and sales lot lighting.

Figure 6-1: Concept of a Layered Lighting Approach for Outdoor Lighting — Lighting Power Allowance (LPA)

Additional Lighting Power allowance for specific applications
General Hardscape Perimeter allowance
General Hardscape Area allowance
General Hardscape Initial allowance
Figure 6-1: Concept of a layered lighting approach for outdoor lighting - Lighting Power Allowance (LPA) . Graphic shows outdoor lighting power densities structured using a layered lighting approach. This image illustrates how the total allowed power for a sales lot with frontage is determined by layering the general hardscape, outdoor sales lot and outdoor sales lot frontage allowances, with specific restrictions associated with the location of the power used for frontage and sales lot lighting.

Image Source: California Energy Commission

The outdoor lighting applications that are addressed by the Energy Code are shown in the first two columns of Table 6-1. The first column is general site illumination applications, which allow trade-offs within the outdoor portion only. The second column is specific outdoor lighting applications, which do not allow trade-offs and are considered “use it or lose it.” The lighting applications in the third column are exempt from lighting power requirements. However, these lighting applications must meet applicable lighting control requirements.

6.2.2 Lighting Power Trade-Offs

The Energy Code does not allow trade-offs between outdoor lighting power allowances and indoor lighting, sign lighting, heating, ventilation, and air-conditioning (HVAC) system, building envelope, or water heating (§140.7(a)).

There is only one type of trade-off permitted for outdoor lighting power. Allowed lighting power determined according to §140.7(d)1 for general hardscape lighting may be traded to specific applications in §140.7(d)2, provided the luminaires used to determine the illuminated area are installed as designed. This means that if luminaires used to determine the total illuminated area are removed from the design, resulting in a smaller illuminated area, then the general hardscape lighting power allowance must also be reduced accordingly.

Allowed lighting power for specific applications may not be traded between specific applications or to hardscape lighting in §140.7(d)1. This means that for each specific application, the allowed lighting power is the smaller of the allowed power determined for that specific application according to §140.7(d)2, or the actual installed lighting power that is used in that specific application. These additional power allowances are “use it or lose it” allowances.

Table 6-1: Scope of the Outdoor Lighting Requirements
Lighting Applications Covered General Hardscape
(trade-offs permitted)
Lighting Applications Covered Specific Applications
(trade-offs not permitted)
Lighting Applications
Not Regulated (only as detailed in § 140.7)
The general hardscape area of a site shall include parking lot(s), roadway(s), driveway(s), sidewalk(s), walkway(s), bikeway(s), plaza(s), bridge(s), tunnel(s), and other improved area(s) that are illuminated.
Canopies: Sales and Non-sales
Tunnels
Drive-Up Windows
Emergency Vehicle Facilities
Building Entrances or Exits
Building Façades
Guard Stations
Hardscape Ornamental Lighting
Outdoor Dining
Primary Entrances for Senior Care Facilities, Police Stations, Healthcare Facilities, Fire Stations, and Emergency Vehicle Facilities
Outdoor Sales Frontage and Lots
Special Security Lighting for Retail Parking and Pedestrian Hardscape
Student Pick-up/Drop-off zone
Vehicle Service Station: Canopies, Hardscape, and Uncovered Fuel Dispenser
ATM Lighting
Security Cameras
Temporary outdoor lighting
Required and regulated by FAA
Required and regulated by the Coast Guard.
For public streets, roadways, highways, and traffic signage lighting, and occurring in the public right-of-way
For sports and athletic fields, and children’s playground
For industrial sites
For public monuments
Signs regulated by §130.3 and § 140.8
For stairs and wheelchair elevator lifts
For ramps that are not parking garage ramps
Landscape lighting
For themes and special effects in theme parks
For outdoor theatrical and other outdoor live performances
For qualified historic buildings

Source: California Energy Commission

Other outdoor lighting applications that are not included in Energy Code Tables 140.7-A or 140.7-B are assumed to be not regulated by the Energy Code. This includes decorative gas lighting and emergency lighting powered by an emergency source as defined by the California Electrical Code. The text in the above list of lighting applications that are not regulated has been shortened for brevity. Please see Section 6.2.3 for details about unregulated lighting applications.

6.2.3 Outdoor Lighting Applications Not Regulated by §140.7

When a luminaire is installed only to illuminate one or more of the following applications, the lighting power for that luminaire shall be exempt from the lighting power requirements in §140.7(a). Refer to the right column of Table 6-1 for a quick reference to the lighting applications that are exempted. Also, the Energy Code clarifies that at least 50 percent of the light from the luminaire must fall within an application to qualify as being installed for that application.

This panel displays referenced content when certain links are clicked.

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2025 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.