Lamp stabilization: Lamp stabilization shall be determined in accordance with:
IES-LM-9 for circleline, and U-tube fluorescent systems;
Code of Federal Regulations - 10 CFR 430.23(q) for linear fluorescent systems;
IES-LM-66 for compact fluorescent systems and induction lighting systems;
IES-LM-79 for light emitting diode systems; and
IES-LM-46 for high intensity discharge systems.
Lamp light output shall be stabilized in advance of taking measurements at each dimming level. Light output shall be considered stabilized when consecutive measurements taken at one minute intervals deviate by no more than 0.5%.
Recording interval: Measured data shall be recorded to a digital file with an interval between each measurement no greater than 0.00005 sec (50 microseconds) corresponding to an equipment measurement rate of no less than 20kHz, and capture at least 1 second of data.
For each dimming level after the lamps have stabilized, record lighting measurements (in footcandles or volts) from test equipment with readings taken at intervals of no greater than 50 microseconds. These readings shall be recorded for a test period of no less than one second.