JA3.2 Summary of Data

Table 3-1 through Table 3-3 give a statistical summary of the TDV conversion factors for electricity, natural gas and propane. Each table has the annual minimum, maximum, and average for each climate zone and building type.

  1. Table 3-1 – TDV Statistical Data – Electricity (kBtu/kWh)
  2. Table 3-2 – TDV Statistical Data – Natural Gas (kBtu/therm)
  3. Table 3-3 – TDV Statistical Data – Propane (kBtu/therm)

Table 3-1 – TDV Statistical Data – Electricity (kBtu/kWh)
     Residential                            Nonresidential (15yr)                              Nonresidential (30 yr)

Climate Zone
Minimum
Average
Maximum
Minimum
Average
Maximum
Minimum
Average
Maximum
1
14.13
27.22
309.69
13.26
28.21
423.98
12.99
27.21
333.97
2
13.92
26.97
2755.84
13.06
27.97
334.02
12.81
27.00
2992.60
3
14.07
27.15
2441.14
13.19
28.12
2924.14
12.93
27.13
2648.86
4
13.95
27.01
1866.06
13.22
28.16
2324.98
12.97
27.18
2028.71
5
14.15
27.25
669.24
13.32
28.27
873.02
13.05
27.28
724.78
6
14.14
26.96
1501.89
13.53
28.11
1546.57
13.17
27.13
1632.17
7
14.20
27.06
662.28
13.51
28.12
1016.86
13.15
27.12
717.65
8
13.84
26.61
923.37
13.63
28.23
1103.70
13.27
27.24
1008.16
9
13.82
26.58
1878.92
13.57
28.15
2072.04
13.21
27.17
2052.46
10
13.81
26.58
682.02
13.52
28.10
917.99
13.16
27.12
743.46
11
13.96
27.02
1533.26
13.16
28.08
2162.91
12.93
27.13
1665.42
12
13.95
27.01
1507.16
13.16
28.09
2112.00
12.93
27.14
1637.22
13
13.89
26.94
2537.01
13.10
28.02
3109.71
12.86
27.05
2757.28
14
13.68
26.42
1911.10
13.51
28.09
2454.87
13.16
27.11
2090.42
15
13.73
26.48
2068.49
13.52
28.10
2533.73
13.17
27.12
2261.44
16
14.63
27.54
1286.61
13.99
28.66
1591.54
13.62
27.65
1396.28

Table 3-2 – TDV Statistical Data – Natural Gas (kBtu/therm)
Residential                            Nonresidential(15yr)                              Nonresidential (30 yr)

Climate Zone
Minimum
Average
Maximum
Minimum
Average
Maximum
Minimum
Average
Maximum
1
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
2
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
3
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
4
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
5
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
6
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
7
330.41
352.40
381.47
226.80
255.27
293.31
259.74
287.70
324.97
8
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
9
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
10
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
11
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
12
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
13
330.15
351.04
378.53
226.53
253.18
288.62
259.47
285.66
320.39
14
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
15
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37
16
330.33
351.58
379.63
226.75
254.56
291.68
259.69
287.01
323.37

Table 3-3 – TDV Statistical Data – Propane (kBtu/therm)

Residential                            Nonresidential(15yr)                              Nonresidential (30 yr)

Climate Zone
Minimum
Average
Maximum
Minimum
Average
Maximum
Minimum
Average
Maximum
1
567.80
626.40 4
686.90
451.71
495.37
540.44
462.53
505.74
550.36
2
567.80
626.40 4
686.90
451.71
495.37
540.44
462.53
505.74
550.36
3
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
4
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
5
567.80
626.40
686.90
451.71
495.37
540.44 4
462.53
505.74
550.36
6
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
7
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
8
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
9
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
10
567.80
626.40 4
686.90
451.71
495.37
540.44
462.53
505.74
550.36
11
567.80
626.40 4
686.90
451.71
495.37
540.44
462.53
505.74
550.36
12
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
13
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
14
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
15
567.80
626.40 4
686.90
451.71
495.37
540.44
462.53
505.74
550.36
16
567.80
626.40
686.90
451.71
495.37
540.44
462.53
505.74
550.36
loading