Each manufacturer shall electronically file with the Executive Director through the MAEDbS a statement for each appliance that is sold or offered for sale in California. The statement shall contain all of the information described in paragraphs (2) through (4) of this subsection and shall meet all of the requirements of paragraph (1) of this subsection and all other applicable requirements in this Article.
The effective dates of this section shall be the same as the effective dates shown in section 1605.1, 1605.2 or Section 1605.3 of this Article for appliances for which there is an energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in section 1605.1, 1605.2, or section 1605.3 of this Article. For appliances with no energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in section 1605.1, 1605.2, or 1605.3 of this Article, the effective date of this section shall be one year after they are added to section 1601 of this Article unless a different effective date is specified.
Exceptions to Section 1606(a) of this Article: Section 1606(a) of this Article is not applicable to:
(1) external power supplies,
(2) small electric motors,
(3) à la carte chargers meeting the EXCEPTION noted in Section 1605.3(w)(2) of this Article.
(4) General service lamps, excluding state-regulated LED lamps and state-regulated small diameter directional lamps subject to the standards in section 1605.3(k) of this Article., or
(5) federally regulated consumer water heaters ≥ 2 and < 20 gallons rated storage volume.
(6) single and dual duct portable air conditioners with variable speed motors.
(A) A statement that the appliance has been tested in accordance with all applicable requirements of Sections 1603 and 1604 of this Article. If Section 1604 of this Article provides more than one test method that may be used, the manufacturer shall identify which method was used.
EXCEPTION 1 to Section 1606(a)(3)(A) of this Article:
For appliances for whom an alternative efficiency determination method (AEDM) was used to determine energy consumption or efficiency values consistent with 10 C.F.R. section 429.70, the manufacturer shall submit a statement that the appliance has been tested in accordance with all applicable requirements of Sections 1603 and 1604 of this Article, or that the appliance has been rated according to an alternative efficiency determination method (AEDM) in accordance with all applicable requirements of section 1604(s) of this Article
EXCEPTION 2. to Section 1606(a)(3)(A) of this Article:
For integral cartridge-filter pool pumps and integral sand-filter pool pumps manufactured on or after July 19, 2021, in lieu of the statement required in section 1606(a)(3)(A) of this Article, a statement that the appliance meets the energy design requirements of sections 1605.1(g)(7)(C) and 1605.1(g)(7)(D) of this Article.
EXCEPTION 3 to section 1606(a)(3)(A) of this Article:
For residential pool pump and motor combinations and residential replacement pool pump motors, in lieu of the statement required in section 1606(a)(3)(A) of this Article, a statement that the appliance meets the design requirements of section 1605.3(g)(5)(A) and 1605.3(g)(5)(B) of this Article.
Exception 1. to Section 1606(a)(3)(C) of this Article:
If an appliance has an alternative test procedure pursuant to section 1603(c)(1) of this Article, or an alternative assessment method specified pursuant to section 1603(c)(2)(A) of this Article, then the statement shall include:
Exception 2. to Section 1606(a)(3)(C) of this Article:
If the Executive Director has specified that there is no test method for an appliance pursuant to section 1603(c)(2)(B) of this Article, then the statement shall include the following information from Table X: Manufacturer's Name, Brand Name, Model Number, and Regulatory Status.
Exception 3. to Section 1606(a)(3)(C) of this Article:
Manufacturers of state-regulated LED lamps and LED versions of state-regulated small-diameter directional lamps may certify estimated values for rated lifetime until testing per section 1604 of this Article is complete. When reporting estimated values, the certification report shall describe the prediction method, which must be generally representative of the methods specified in 10 C.F.R. Appendix BB to subpart B of part 430, “Uniform Test Method for Measuring the Input Power, Lumen Output, Lamp Efficacy, Correlated Color Temperature (CCT), Color Rendering Index (CRI), Power Factor, Time to Failure, and Standby Mode Power of Integrated Light-Emitting Diode (LED) Lamps.” Manufacturers shall maintain records of the development of all estimated values and any associated initial test data. Manufacturers shall update the certification in the MAEDbS upon completion of the required test procedures for rated lifetime.
Example: An air conditioner is tested using the appropriate test method specified in Section 1604, and the test method does not include specific instructions about the precision of reporting.
- Cooling capacity is measured as: 36,014 Btu per hour.
- For cooling capacity, consumers prefer higher values.
- The manufacturer may not report any value over 36,014 Btu per hour.
- The manufacturer chooses to report 36,000 Btu per hour.
- Electrical energy use is measured at 3,487 watts.
- For electrical energy use, consumers prefer lower values.
- The manufacturer may not report any value under 3,487 watts.
- The manufacturer chooses to report 3,500 watts.
- Using the data the manufacturer chooses to report, EER = 36,000/3,500 = 10.285714.
- For EER, consumers prefer higher values.
- The manufacturer may not report any value of EER over 10.285714 (if EER is reported with only one decimal place, the maximum value would be 10.2).
- The manufacturer chooses to report EER = 10.2 Btu per watt hour.
- If the manufacturer had chosen to report the cooling capacity as 36,014 Btu per hour, and the electrical energy use as 3,487 watts, the calculated EER would have been 36,014/3,487 = 10.328076. In this case the manufacturer could not report any value of EER over 10.328076 (if EER is reported with only one decimal place, the maximum value would be 10.3).
A - Refrigerators, Refrigerator-Freezers, and Freezers
B - Room Air Conditioners
C - Central Air Conditioners
D - Portable Air Conditioners
E - Space Heating Products
F - Water Heaters
G - Pool Heaters, Portable Electric Spas, Residential Pool Pump and Motor Combinations…
H - Plumbing Fittings
I - Plumbing Fixtures
J - Fluorescent Lamp Ballasts and Deep-Dimming Lamp Ballasts
K - Lamps
L - Emergency Lighting
M - Traffic Signal Modules
N - Luminaires and Torchieres
O - Dishwashers
P - Clothes Washers
Q - Clothes Dryers
R - Cooking Products and Food Service Equipment
S - Electric Motors
T - Distribution Transformers
U – None.
V - Computers, Computer Monitors, Televisions, Signage Displays, and Consumer Audio and Video Equipment
W - Battery Chargers and Battery Charger Systems
X – Landscape Irrigation Equipment
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Non‐Commercial Refrigerators, Non‐Commercial Refrigerator‐Freezers, Non‐Commercial Freezers |
| |
| *Product Class | Category in Table A-2 or A‐3 (specify) | |
| Access1, 2 | Door, drawer, both door and drawer | |
| Kitchen Unit1, 2 | True, False | |
| Refrigerator Volume |
| |
| Freezer Volume |
| |
| Total Volume |
| |
| Adjusted Total Volume |
| |
| Height |
| |
| Width |
| |
| Depth |
| |
| Annual Energy Consumption (low) |
| |
| Annual Energy Consumption (high) |
| |
| Annual Energy Consumption (mean) |
| |
| Anti‐sweat Heater Switch | True, False | |
| Refrigerant Type1, 2 | Ozone‐depleting, non‐ozone‐ depleting | |
| Insulation Type1, 2 | Ozone‐depleting, non‐ozone‐ depleting | |
| Self‐contained Commercial Refrigerators with or without doors, Self‐contained Commercial Refrigerator‐ Freezers with or without doors, Self‐ contained Commercial Freezers with or without doors, Self‐contained Commercial Refrigerators specifically designed for display and sale of bottled or canned beverages with or without doors, Remote Condensing Commercial Refrigerators, Remote Condensing Commercial Freezers, Commercial Ice Cream Freezers(Note: units with multiple compartments must certify data for each compartment) |
| |
| *Cabinet Style | Ice cream cabinet; milk or beverage cabinet; milk, beverage, or ice cream cabinet; undercounter cabinet; other reach‐in cabinet; pass‐through cabinet; roll‐in or roll‐through cabinet; preparation table; buffet table; wedge case; work top table. | |
| *Defrost System | Automatic, manual, partial‐automatic | |
| *Type | Ice‐cream application, low‐temperature application, medium‐temperature application, pull‐down application | |
| Total Compartments (for hybrid models and refrigerator-freezers) |
| |
| Equipment Family | Vertical open, semivertical open, horizontal open, vertical closed transparent, horizontal closed transparent, vertical closed solid, horizontal closed solid, service over counter | |
| Condensing Unit Configuration | Remote, self‐contained | |
| Multiple Compartments Number Code |
| |
| Total Display Area (TDA) |
| |
| Total Volume |
| |
| Height |
| |
| Width |
| |
| Depth |
| |
| Anti‐condensate Energy Consumption (AEC) (for hybrid models and refrigerator-freezers) |
| |
| Condensate Evaporator Pan Energy Consumption (PEC) (for hybrid models and refrigerator-freezers) |
| |
| Defrost Energy Consumption (DEC) (for hybrid models and refrigerator-freezers) |
| |
| Fan Energy Consumption (FEC) (for hybrid models and refrigerator-freezers) |
| |
| Compressor Energy Consumption (CEC) (for hybrid models and refrigerator-freezers) |
| |
| Lighting Energy Consumption (LEC) (for hybrid models and refrigerator-freezers) |
| |
| Other Energy Consumption (OEC) (for hybrid models and refrigerator-freezers) |
| |
| Daily Energy Consumption |
| |
| Calculated Daily Energy Consumption (CDEC) |
| |
| Total Daily Energy Consumption (TDEC) |
| |
| Refrigerant Type | Ozone‐depleting, non‐ozone‐depleting | |
| Insulation Type | Ozone‐depleting, non‐ozone‐depleting | |
| Automatic Commercial Ice‐ Makers |
| |
| *Equipment Type | Ice‐making head, remote‐condensing, self‐contained, both remote‐condensing and remote‐compressor | |
| *Cooling Type | Air, water | |
| *Ice Maker Process Type | Batch, continuous, cube other (specify) | |
| Harvest Rate |
| |
| Energy Consumption |
| |
| Water Consumption |
| |
| Ice Hardness Adjustment Factor (for continuous type models) |
| |
| Water Dispensers |
| |
| *Type | Bottle type; Bottle type with compartment; Pressure type, bubbler; Pressure type with compartment, bubbler; Pressure type, faucet; Pressure type with compartment, faucet, Point‐of‐Use | |
| *Condenser Cooling Medium | Air‐cooled; Water‐cooled | |
| *Style | Free‐standing; Flush‐to‐Wall; Wall Hung; Wall Hung semi‐recessed; Remote; Recessed | |
| *Refrigerated Compartment |
| |
| Temperatures delivered | Cold only, cook (ambient) and cold, hot and cold | |
| Cooling Capacity (gallons/hour) |
| |
| Heating Capacity (6‐oz. cup per hour) |
| |
| Standby Energy Consumption (kWh/day) |
| |
| Walk‐in Coolers, and Walk‐in Freezers: Doors |
| |
| Door Type | Passage door (medium temperature), passage door (low temperature), freight door (medium temperature), freight door (low temperature), display door (medium temperature), display door (low temperature) | |
| Door surface area (ft2) |
| |
| Transparent reach-in? | Door, window, both | |
| Glass Type of Doors and Door Windows (if applicable) | 1” triple pane insulated, 1” triple pane tempered, 2-pane Low-E Gas Fill, 3-pane gas fill, 3-pane heat reflective, 3-pane Low-E gas fill, 3-pane reflective gas fill, 3-pane heated, 3- pane unheated, none | |
| Anti-sweat heater power draw (W per ft2 of door opening) (if applicable) |
| |
| Door insulation R-value (if applicable) |
| |
| All applicable design standards incorporated? | True, False | |
| Daily energy consumption (kWh/day) |
| |
| Equipped with a timer, control system, or other demand-based control reducing lighting power and/or heater wire and/or other electricity-consuming device? | Lighting, heater wire, other electricity-consuming device, lighting + heater wire, lighting + other electricity-consuming device, heater wire + other electricity-consuming device, all, none | |
| Total rated lighting power (W) (if applicable) | c | |
| Total rated heater wire power (W) (if applicable) |
| |
| Total rated other electricity-consuming device power (W) (if applicable) |
| |
| Walk‐in Coolers, and Walk‐in Freezers: Panels | Panel Type | Wall panels for walk-in coolers, ceiling panels for walk-in coolers, wall panels for walk-in freezers, ceiling panels for walk-in freezers, floor panels for walk-in freezers |
| R-value of wall insulation (if applicable) |
| |
| R-value of ceiling insulation (if applicable) |
| |
| R-value of floor insulation (if applicable) |
| |
| Walk‐in Coolers, and Walk‐in Freezers: Refrigeration Systems | Refrigeration system Type | Dedicated condensing system medium temperature indoor; Dedicated condensing system medium temperature outdoor; Dedicated condensing system low temperature indoor; Dedicated condensing system low temperature outdoor; unit cooler medium temperature, unit cooler low temperature |
| Is outdoor dedicated condensing system also certified (for indoor dedicated condensing systems only? | True, False | |
| Model number for outdoor dedicated condensing system (only applicable for indoor dedicated condensing systems where outdoor dedicated condensing system is also certified) |
| |
| Refrigeration system net capacity (Btu/hr) (if applicable) |
| |
| Evaporator fan motor horsepower (if applicable) |
| |
| Condenser fan motor horsepower (if applicable) |
| |
| All applicable design requirements incorporated? | True, False | |
| Process cooling refrigeration system? | True, False | |
| Annual Walk-in Energy Factor(AWEF) |
| |
| Configuration tested for certification (if applicable) | Condensing unit only, unit cooler only, single package dedicated system, matched pair | |
| Refrigerated Bottled or Canned Beverage Vending Machines |
| |
| Equipment Class (reporting of Combination A or Combination B for models manufactured on or after January 8, 2019) | Class A, Class B, Combination A,Combination B | |
| Door Type | Glass front, closed front, | |
| Machine use designation | Indoor, indoor / outdoor | |
| Maximum Daily Energy Consumption at 75°F. Ambient Temperature |
| |
| Standard Vendible Capacity |
| |
| Low Power State – lighting | True, false | |
| Low Power State – refrigeration | True, false | |
| Low Power State – whole machine | True, false | |
| On‐Site Adjustable by Operator or Owner | True, false | |
| Refrigerant Type | Ozone‐depleting, non‐ozone‐depleting | |
| Insulation Type | Ozone‐depleting, non‐ozone‐depleting | |
| Internal volume |
| |
| Miscellaneous Refrigeration Products | Product Class Variable Defrost Control Least time Between Defrosts (hours) (when “Variable Control” = True) | 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 |
| Max time Between Defrosts (hours) (when “Variable Control” = True) |
| |
| Variable Anti-Sweat Heater Control Heater Watts at 5%, 15%, 25%, 35%, 45%, 55%, 65%, 75%, 85%, and 95% humidity (Watts) (when “Variable Anti-Sweat Heater Control” = True) | True, False | |
| Testing Conducted with Modifications to Standard Temperature Sensor Locations Total Refrigerated Volume (ft3)Total Adjusted Volume (ft3)Annual Energy use (kWh/year) | True, False | |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Packaged Terminal Air Conditioners, and Packaged Terminal Heat Pumps
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Room Air Conditioners and Room Air‐Conditioning Heat Pumps |
| |
| *Voltage |
| |
| *Electrical Phase | 1, 3 | |
| *Type | Room air conditioner, room air conditioning heat pump, casement‐only room air conditioner, casement‐slider room air conditioner. | |
| *Louvered Sides | Yes, no | |
| Cooling Capacity at 95°F |
| |
| Electrical Input at 95°F |
| |
| Combined Energy Efficiency Ratio at 95°F |
| |
| Standby and Off Mode Annual Energy Consumption |
| |
| Heating Capability | Heat pump, electric resistance heating, heat pump and electric resistance heating, no heating capability | |
| Refrigerant Type1 | Ozone‐depleting, non‐ozone‐depleting | |
| Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps |
| |
| *Voltage |
| |
| *Electrical Phase | 1, 3 | |
| *Type | PTAC, PTHP | |
| Size | Standard, non‐standard | |
| Cooling Capacity at 95°F |
| |
| Electrical Input at 95°F |
| |
| Combined Energy Efficiency Ratio (EER) at 95°F |
| |
| Heating Capability | Heat pump, electric resistance heating, heat pump and electric resistance heating, no heating capability | |
| Heating Capacity (for models with heating capability only) |
| |
| Electrical Input (for models with heating capability only) |
| |
| Coefficient of Performance (for models with heating capability only) |
| |
| Refrigerant Type1 | Ozone‐depleting, non‐ozone‐depleting | |
| Compressor Power1 |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Data Submittal Requirements
| Appliance | Required Information | Possible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Air Filters manufactured on or after July 1, 2024 | Length of tested air filter (inches) |
|
| Width of tested air filter (inches) |
| |
| Depth of tested air filter (inches) |
| |
| Face Area of tested air filter (inches) |
| |
| Test Procedure used | AHRI Standard 680 (I-P)-2017, ANSI/ASHRAE Standard 52.2-2017 | |
| Face Velocity Utilized for the test procedure (feet per minute) |
| |
| Minimum Efficiency Reporting Value (MERV) (if ANSI/ASHRAE Standard 52.2-2017 was used.) |
| |
| Particle size Efficiency for 0.3 to 1.0 µm particle size |
| |
| Particle size Efficiency for 1.0 to 3.0 µm particle size |
| |
| Particle size Efficiency for 3.0 to 10 µm particle size |
| |
| Airflow Rate value 1 (cubic feet per minute) |
| |
| Airflow Rate value 2 (cubic feet per minute) |
| |
| Airflow Rate value 3 (cubic feet per minute) |
| |
| Airflow Rate value 4 (cubic feet per minute) |
| |
| Airflow Rate value 5-(cubic feet per minute) (Maximum Rated Airflow Rate if ANSI/ASHRAE Standard 52.2-2017 was used) |
| |
| Calculated Airflow Rate value at an Initial Resistance of 0.1 inches water column (cubic feet per minute) |
| |
| Initial Resistance at air flow rate value 1 (inches water column) |
| |
| Initial Resistance at air flow rate value 2 (inches water column) |
| |
| Initial Resistance at air flow rate value 3 (inches water column) |
| |
| Initial Resistance at air flow rate value 4 (inches water column) |
| |
| Initial Resistance at air flow rate value 5 (inches water column) (if ANSI/ASHRAE Standard 52.2-2017 was used) |
| |
| Final Resistance at the point where test is terminated and results determined (inches water column) |
| |
| Dust Holding Capacity (grams) |
|
| Central Air Conditioners and Heat Pumps Other than Multi-Split Systems (tested under 10 C.F.R. section 420.23(m) (Appendix M1 to subpart B of part 430)) | Individual Model Number Covered by Basic Model (outdoor unit or package unit) | Individual Model Number Covered by Basic Model (outdoor unit or package unit) |
| Individual Model Number (indoor unit) (if applicable) | Gas, oil, electric heat pump, electric resistance, heat pump and electric resistance, none | |
| Individual Model Number (air mover or indoor unit if fan is part of indoor unit) (if applicable) |
| |
| Product Group Code |
| |
| Certification Is Based on a Waiver of DOE's Test Procedure Requirements | True, False | |
| Certification Is Based upon an Exception Relief from an Applicable Standard by DOE's Office of Hearing and Appeals | True, False | |
| Cooling Capacity (Btu/h) |
| |
| Heating Capacity (Btu/h) (heat pumps only) (voluntary) |
| |
| Seasonal Energy Efficiency Ratio 2 (SEER2) (Btu/Wh) |
| |
| Heating Seasonal Performance Factor 2 (HSPF2) (Btu/Wh) (heat pumps only) |
| |
| Average Off Mode Power Consumption Rating is Based on Testing of This Combination | True, False | |
| Average Off Mode Power Consumption (watts) |
| |
| Energy Efficiency Ratio 2 (EER2) (in Btu/Wh) (if applicable) |
| |
| Coil System Type | Coil-Only, Blower Coil | |
| This is a Variable-Speed Compressor System | True, False | |
| Type of Air Conditioner or Heat Pump Used in Testing or Rating | Ceiling-Mount, Wall-Mount, Small-Duct High-Velocity (SDHV), Space Constrained, Mobile Home, Conventional | |
| Multi-Split System Central Air Conditioners and Heat Pumps (tested under 10 C.F.R. section (Appendix M1 to subpart | Manufacturer (outdoor unit) |
|
| Brand Name (outdoor unit) |
| |
| Individual Model Number Covered by Basic Model (outdoor unit) |
| |
| Indoor Unit Manufacturer(s) |
| |
| Indoor Unit Individual Model Number(s) |
| |
| Air Mover Manufacturer(s) (if applicable) |
| |
| Air Mover Brand(s) (if applicable) |
| |
|
Air Mover Individual Model Number(s) (if applicable) |
| |
| Product Group Code |
| |
| Certification is Based on a Waiver of DOE's Test Procedure Requirements | True, False | |
| Certification is Based upon an Exception Relief from an Applicable Standard by DOE | True, False | |
| Cooling Capacity (Btu/h) |
| |
| Heating Capacity (Btu/h) (heat pumps only) (voluntary) |
| |
| Number of Indoor Units Tested with the Outdoor Unit |
| |
| Seasonal Energy Efficiency Ratio 2 (SEER2)(Btu/Wh) |
| |
| Type of Air Conditioner or Heat Pump Used in Testing or Rating | Ceiling-Mount, Wall-Mount, Low-Static, Mid-Static, Small Duct High Velocity, Space Constrained, Mobile Home Conventional, Not Otherwise Listed | |
| Heating Seasonal Performance Factor 2(HSPF2) (Btu/W-h) (heat pumps only) |
| |
| Average Off Mode Power Consumption Rating is Based on Testing of This Combination | True, False | |
| Average Off Mode Power Consumption (Watts) |
| |
| Energy Efficiency Ratio 2 (EER2) (Btu/Wh) (if applicable) |
| |
| This is a Variable-Speed Compressor System | True, False | |
| Commercial Air Conditioners and Commercial Heat Pumps | Individual Model Number Covered by Basic Model |
|
| Certification Is Based Upon a Waiver of DOE's Test Procedure Requirements | True, False | |
| Seasonal Energy Efficiency Ratio (SEER) (Btu/Wh) (if applicable) |
| |
| Energy Efficiency Ratio (EER) (Btu/Wh) (if applicable) |
| |
| Integrated Energy Efficiency Ratio (IEER) (Btu/Wh) (if applicable) |
| |
| Heating Seasonal Performance Factor (HSPF) (if applicable) |
| |
| Coefficient of Performance (COP) (if applicable) |
| |
|
Rated Cooling Capacity (Btu/h) |
| |
| Heating Type | Electric Resistance Heating or No Heating, Heating Types Other than Electric Resistance, or All | |
| Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps | Outdoor Unit Module 1 Model Number |
|
| Outdoor Unit Module 2 Model Number (if applicable) |
| |
| Outdoor Unit Module 3 Model Number (if applicable) |
| |
| Outdoor Unit Module 4 Model Number (if applicable) |
| |
| Outdoor Unit Module 5 Model Number (if applicable) |
| |
| Product Group Code |
| |
| Rated Cooling Capacity (Btu/h) |
| |
| Certification Is Based on a Waiver of DOE's Test Procedure Requirements | True, False | |
| Certification Is Based upon an Exception Relief from an Applicable Standard by DOE's Office of Hearing and Appeals | True, False | |
| Seasonal Energy Efficiency Ratio (SEER) (Btu/Wh) (if applicable) |
| |
| Downflow Unit SCOP (Air‐cooled, water‐cooled, glycol‐cooled, chilled-water-cooled models only) |
| |
| Heating Seasonal Performance Factor (HSPF)(if applicable) |
| |
| Integrated Energy Efficiency Ratio (IEER) (Btu/Wh) (if applicable) |
| |
| Coefficient of Performance (if applicable) |
| |
| Rated Heating Capacity (Btu/h) (if applicable) |
| |
| Tested Combination | Non-Ducted, Ducted, Small Duct High-Velocity (SDHV), Non-Ducted/Ducted Mix, Non-Ducted/Small Duct High-Velocity (SDHV) Mix, Ducted/Small Duct High-Velocity (SDHV) Mix | |
| Indoor Units Identified in the Tested Combination |
| |
| Single Package Vertical Air Conditioners and Heat Pumps | Individual Model Number Covered by Basic Model |
|
| Sample Size (number of units tested) |
| |
| Certification Is Based Upon a Waiver of DOE's Test Procedure Requirements | True, False | |
| Certification Is Based Upon an Exception Relief from an Applicable Standard by DOE's Office of Hearing and Appeals | True, False | |
| Energy Efficiency Ratio (EER) (Btu/Wh) |
| |
| Coefficient of Performance (COP) (if applicable) |
| |
| Rated Cooling Capacity (Btu/h) |
| |
| Computer Room Air Conditioners | Individual Model Number Covered by Basic Model |
|
| Certification Is Based Upon a Waiver of DOE's Test Procedure Requirements | True, False | |
| Certification Is Based Upon an Exception Relief from an Applicable Standard by DOE's Office of Hearing and Appeals | True, False | |
| Sensible Coefficient of Performance (SCOP) |
| |
| Net Sensible Cooling Capacity (Btu/h) |
| |
| Net Cooling Capacity (Btu/h) |
| |
| Rated Airflow (standard cubic feet per minute (SCFM)) |
| |
| Configuration | Upflow, Downflow | |
| Economizer Present | Economizer Present True, False | |
| Condenser Medium | Condenser Medium Air, water, or glycol-cooled |
| Heat pump water-heating packages | Voltage* |
| ||
| Phase* | 1, 3 | |||
| Refrigerant Type* | Ozone-depleting, non-ozone-depleting | |||
| Compressor Motor Design* | Single-speed, dual-speed, multiple-speed, variable-speed | |||
| OD Fan Motor Design* | Single-speed, dual-speed, multiple-speed, variable-speed | |||
| Model number includes all components? | True, False | |||
| Is the model designed for space cooling? | True, False | |||
| Cooling Capacity (BTU per hour) if applicable |
| |||
| Cooling power input (watts) if applicable |
| |||
| Energy Efficiency Ratio (EER) if applicable |
| |||
| Integrated part load value (IPLV) |
| |||
| Heating Capacity (BTU per hour) at 47º |
| |||
| Heating power input (watts) at 47º |
| |||
| Coefficient of Performance (COP) at 47º |
| |||
| Heating Capacity (BTU per hour) at 17º |
| |||
| Heating power input (watts) at 17º |
| |||
| Coefficient of Performance (COP) at 17º |
| |||
| Heating Capacity (BTU per hour) of heat reclaim2 |
| |||
| COPR of heat reclaim2 |
| |||
* “Identifier” information as described in Section 1602(a)|topic=(a) General.
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Portable Air Conditioners, Evaporative Coolers, Ceiling Fans, Ceiling Fan Light Kits, Whole House Fans, Residential Exhaust Fans, Dehumidifiers, Residential Furnace Fans and Commercial and Industrial Fans and Blowers
Data Submittal Requirements
| Appliance | Required Information | Possible Answers | |
| All Appliances | * Manufacturer’s Name |
| |
| * Brand Name |
| ||
| *Model Number |
| ||
| Date model to be displayed |
| ||
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | ||
| Single-Duct and Dual-Duct Portable Air Conditioners | *Duct configuration | Single-duct, dual-duct, ability to operate in both single-duct and dual-duct configurations | |
| Heating function available | True, False | ||
| Dehumidification mode available | True, False | ||
| Primary condensate removal feature | Auto-evaporation, gravity drain, removable internal collection bucket, condensate pump | ||
| Single-Duct Portable Air Conditioners | Combined Energy Efficiency Ratio (CEER) (Btu/Wh) |
| |
| Seasonally Adjusted Cooling Capacity (SAAC) (Btu/h |
| ||
| Adjusted Cooling Capacity at 83⁰F conditions (Btu/h |
| ||
| Adjusted Cooling Capacity at 95⁰F conditions (Btu/h |
| ||
| Annual energy consumption in off-cycle mode (kWh/year) |
| ||
| Annual energy consumption in inactive or off mode (kWh/year) |
| ||
| Annual energy consumption in cooling mode (kWh/year) |
| ||
| Dual-Duct Portable Air Conditioners | Combined Energy Efficiency Ratio (CEER) (Btu/Wh) |
| |
| Seasonally Adjusted Cooling Capacity (SAAC) (Btu/h |
| ||
| Adjusted Cooling Capacity at 83⁰F conditions (Btu/h |
| ||
| Adjusted Cooling Capacity at 95⁰F conditions (Btu/h |
| ||
| Annual energy consumption in off-cycle mode (kWh/year) |
| ||
| Annual energy consumption in inactive or off mode (kWh/year) |
| ||
| Annual energy consumption in cooling mode at 83⁰F conditions (kWh/year) |
| ||
| Annual energy consumption in cooling mode at 95⁰F conditions (kWh/year) |
| ||
| Spot Air Conditioners | *Type | Single package, air‐cooled; single package, evaporatively‐cooled; split system: air‐cooled condensing unit, coil with blower; split system: evaporatively‐cooled condensing unit, coil alone; single package, air‐cooled (FD); single package, evaporatively‐cooled (FD); split system: air‐cooled condensing unit, coil with blower (FD); split system: evaporatively‐ cooled condensing unit, coil alone (FD) | |
| Cooling Capacity |
| ||
| Total Electrical Input |
| ||
| Cooling Efficiency Ratio (CER) |
| ||
| Fan Electrical Input |
| ||
| Refrigerant Type | Ozone‐depleting, non‐ozone‐depleting | ||
| Evaporative Coolers (only those subject to the evaporative cooler testing requirements in section 1604(d) of this Article | *Type Evaporative Media Saturation Effectiveness (%) (for direct evaporative coolers only) | Direct, indirect, indirect/direct | |
|
| |||
|
Media Type (for direct evaporative coolers only) | Expanded paper, woven plastic, aspen wood, rigid cellulose, other (specify). | ||
| Cooling Effectiveness (for indirect evaporative coolers only) |
| ||
| Total Power (watts) |
| ||
| Airflow Rate (CFM) |
| ||
| Ceiling Fans | *Ceiling fan type (required for models manufactured on or after January 21, 2020 only) | High-speed small-diameter (HSSD), hugger, large diameter, standard, very small-diameter (VSD) | |
| Diameter (inches) |
| ||
| CFM (low, medium, high) |
| ||
| Watts (low, medium, high) |
| ||
| Efficacy (low, high) [CFM/watt] (required for models manufactured before January 21, 2020 only) |
| ||
| Efficacy [CFM/watt] (required for models manufactured on or after January 21, 2020 only) |
| ||
| Fan speed controls separate from light controls | True, false | ||
| Adjustable Speed Controls | (Specify) speed, variable | ||
| Reversible Fan Action Capable | True, False, Exception [See Section 1605.1(d)(1)(A)(3) of this Article] | ||
| Light Source Type | Compact fluorescent, incandescent, other (specify), None | ||
| Standby Power (watts) |
| ||
| Ceiling Fan Light Kits manufactured before January 21, 2020 | Socket Type | Medium screw base, pin‐based; other (specify) | |
| Packaged with all appropriate lamps to fill all sockets | True, False | ||
| Screw-based Lamps Requirement (screw-base only) | 1605.1(d)(2)(A)(1) of this Article (specify) | ||
| Meet 1605.1(d)(2)(B) (pin-based sockets only) | True, False | ||
| Operate with lamps totaling more than 190 watts (other socket types only) | True, False | ||
| Ceiling Fan Light Kits manufactured on or after January 21, 2020 |
| ||
| Socket Type | Medium screw base, pin‐based; other (specify) | ||
| Packaged with all appropriate lamps to fill all sockets | True, False | ||
| Lumens for each basic model of lamp or each basic model of integrated SSL (lm) |
| ||
| Rated wattage (watts) |
| ||
| Efficacy (lm/W) |
| ||
| Medium screw base sockets packaged with compact fluorescent lamps | True, False | ||
| Medium screw base compact fluorescent lamps meet section 1605.1(d)(2)(B). of this Article (medium screw base sockets packaged with compact fluorescent lamps only) | True, False | ||
| Pin-based sockets for fluorescent lamps | True, False | ||
| Uses an electronic ballast (Pin-based sockets for fluorescent lamps only) | True, False | ||
| Whole House Fans and Residential Exhaust Fans | *Residential Exhaust Fan Type | Inline single‐port, Inline multi‐port, Range hood, Bathroom and utility room | |
| *Whole‐House Fan Type | Belt‐drive single‐fan, Belt‐drive dual‐fan, Direct‐drive single‐fan, Direct‐drive dual‐ fan | ||
| Fan Motor Power (watts) |
| ||
| Air Flow (CFM) |
| ||
| Air Flow Efficiency (CFM/watt) |
| ||
|
|
| ||
| Dehumidifiers | Dehumidifier Type | Portable dehumidifiers with a capacity less than or equal to 25 pints per day, Portable dehumidifiers with a capacity greater than 25 pints per day and less than or equal to 50 pints per day, Portable dehumidifiers with a capacity greater than 50 pints per day, Whole-home dehumidifiers with a product case volume less than or equal to 8 cubic feet, Whole-home dehumidifiers with a product case volume greater than 8 cubic feet | |
| Water Capacity (pints per day) |
| ||
| Case Volume |
| ||
| Integrated Energy Factor (Liters/Kilowatt Hour) |
| ||
| Residential Furnace Fans | Furnace Fan Types | Non-weatherized, non-condensing gas (NWG-NC); Non-weatherized, condensing gas (NWG-C); Weatherized non-condensing gas (WG-NC); Weatherized condensing gas (MH-NWG-C);Non-weatherized, non-condensing oil (NWO-NC); Non-weatherized electric furnace/ modular blower fan (NWEF/NWMB); Mobile home non-weatherized, non-condensing gas (MH-NWG-NC); Mobile home non-weatherized, condensing gas (MH-NWG-C); Mobile home electric furnace/modular blower fan (MH-EF/MB); Mobile home non-weatherized oil (MG-NOW); Mobile home weatherized gas | |
| Wattage |
| ||
| Airflow at the maximum airflow-control setting (in cfm) (QMax) |
| ||
| Fan Energy Rating (FER) |
| ||
| Fan type |
| ||
| Commercial and Industrial Fans and Blowers manufactured on or after April 21, 2024 | Fan impeller diameter (in.) | Centrifugal housed, centrifugal inline, centrifugal unhoused, centrifugal PRV supply, centrifugal PRV exhaust, axial inline, axial PRV, inline mixed-flow, power roof/wall ventilators, axial panel, radial housed | |
| Type of Motor (if fans sold with a motor) |
| ||
| Motor nameplate horsepower (if fan sold with an induction motor) (hp) | None, Single-phase induction, Polyphase induction, Synchronous DC (including ECM), Permanent magnet AC, or Other | ||
| Pressure type |
| ||
| Transmission type (if fan is sold with a transmission) | S = Static pressure T = Total pressure | ||
| Type of Controller (if fan sold with controller) | Direct, V-belt, synchronous-belt, flexible coupling, none | ||
| Maximum fan speed (RPM) | None, Variable frequency drive, or Other | ||
| Airflow at maximum fan speed (CFM) |
| ||
| Pressure at maximum fan speed (inches water gauge) |
| ||
| FEPact at maximum fan speed (kW |
| ||
| FEPref at maximum fan speed (kW) |
| ||
| Maximum pressure (inches water gauge) |
| ||
| Airflow at maximum pressure (CFM) |
| ||
| Fan speed at maximum pressure (RPM) |
| ||
| FEPact at maximum pressure (kW) |
| ||
| FEPref at maximum pressure (kW) |
| ||
| Maximum air flow (CFM) |
| ||
| Pressure at maximum airflow (inches water gauge) |
| ||
| Fan speed at maximum airflow (RPM) |
| ||
| FEPact at maximum airflow (kW) |
| ||
| FEPref at maximum airflow (kW) |
| ||
| Is the model a Series tested fan? |
| ||
| Associated Series Tested Fan Model Number (if not a series tested fan | Yes, No | ||
| Method used to determine FEPact of test method in section 1604(d) |
Fan product line and model, (Field is N/A if it is a Series tested fan) | ||
|
|
| ||
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Space Heating Products
Data Submittal Requirements
| Appliance | Required Information | Possible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| All Space Heaters |
| |
| *Energy Source | Natural gas, LPG, oil, combination (natural gas and oil), electricity | |
| *Burner Type | Induced draft, luminous, injection type, power, pressure | |
| Constant burning pilot light, (for gas or oil models only) | True, False | |
| *Labeled for Outdoor Installation | True, False | |
| *Electrical Phase | 1, 3, none | |
| Draft Equipment1, 2 | Draft hood, draft diverter, barometric regulator, none | |
| Off‐Cycle Devices | Stack damper, electro‐mechanical inlet damper, electro‐mechanical flue damper, none | |
| Flue Gas | Condensing, non‐condensing | |
| Control | Single‐stage, two‐stage modulating, step modulating | |
| Fan Motor Design (furnaces only)1, 2 | Single‐speed, dual‐speed, multiple‐speed, variable speed | |
| Total Nominal Fan Motor Horsepower (furnaces only) |
| |
| Fan Motor Type (furnaces only) | Premium, standard | |
| Fan Motor Power Factor (furnaces with variable‐speed motors only)1, 2 |
| |
|
Pump Motor Design (boilers only). Note: This information is not required for boilers that are not provided with a pump. |
Single‐speed, dual‐speed, multiple‐speed, variable speed | |
|
Total Nominal Pump Motor Horsepower (boilers only). Note: This information is not required for boilers that are not provided with a pump. |
| |
|
Pump Motor Type (boilers only) Note: This information is not required for boilers that are not provided with a pump. |
Premium, standard | |
| Pump Motor Power Factor (boilers with variable‐speed motors only)1, 2 |
| |
| Nameplate Input Rating |
| |
| Rated Output |
| |
| Central Furnaces |
| |
| *Mobile Home | True, False | |
| *Air Flow Direction | Up, down, horizontal | |
| Weatherized (required for non-mobile‐home furnaces manufactured on or after November 19, 2015 only) | True, False | |
| Fan Blower Capacity, High, at 0.5” W.C.1, 2 |
| |
| Fan Blower Capacity, Low, at 0.5” W.C.1, 2 |
| |
| Thermal Efficiency (for models ≥ 225,000 Btu/hour input and for three‐phase equipment < 225,000 Btu/hour input for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76 |
| |
| Standby Watts [controls, not fan energy] (for models ≥ 225,000 Btu/hour input only)1, 2 |
| |
| Annual Fuel Energy Consumption (for models < 225,000 Btu/hour input only, except for three‐phase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76 ) |
| |
| Annual Fuel Utilization Efficiency [AFUE] (for models < 225,000 Btu/hour input only, except for three‐phase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76) |
| |
| Annual Auxiliary Electrical Energy Consumption (for models < 225,000 Btu/hour input only, except for three‐phase equipment for which the manufacturer chooses to test using 10 C.F.R. sections 431.75 and 431.76 |
| |
| Thermal Efficiency at Minimum Capacity Provided and Allowed by the Controls (for models ≥ 225,000 Btu/hour input only)1, 2 |
| |
| Maximum Standby Mode Electrical Power Consumption (Watts) (applies to models manufactured on or after May 1, 2013 only)1, 2 |
| |
| Maximum Off Mode Electrical Power Consumption (Watts) (applies to models manufactured on or after May 1, 2013 only) 1, 2 |
| |
| Vented Home Heating Equipment |
| |
| *Type | Room heater (vented fan); room heater (gravity); floor furnace (fan); floor furnace (gravity); wall furnace (direct vent fan); wall furnace (direct vent gravity); wall furnace (vented fan); wall furnace (vented gravity) | |
| Annual Fuel Utilization Efficiency (AFUE) |
| |
| Auxiliary Electric Power (for fan‐type heaters only) |
| |
| Average Annual Auxiliary Electrical Energy Consumption (for fan‐type heaters only)1 |
| |
| Duct Furnaces and Unit Heaters |
| |
| *Type | Duct furnace; low static unit heater; high static unit heater; floor‐mounted unit heater | |
| Thermal Efficiency at Maximum Rated Capacity (mandatory for duct furnaces, voluntary for unit heaters only) |
| |
| Energy Consumption During Standby (mandatory for duct furnaces, voluntary for unit heaters only) |
| |
| Thermal Efficiency at Minimum Rated Capacity (mandatory for duct furnaces, voluntary for unit heaters only) |
| |
| Power‐Venting | True, False | |
| Automatic Flue Damper | True, False | |
| Infrared Gas Space Heaters |
| |
| *Type | Patio heater, non‐patio heater | |
| Intensity | High, low | |
| Radiant Tube Type | True, False | |
| Portable | True, False | |
| Vented | True, False | |
| Physically Possible to Measure Radiant Coefficient | True, False | |
| Combustion Efficiency (for models using ANSI test method only) |
| |
| Radiant Coefficient (for models using ANSI test method only; for models for which it is physically possible to measure radiant coefficient only) |
| |
| Effective Heating Area (for patio heaters only) |
| |
| Efficiency Index (for patio only) |
| |
| Combination Space‐Heating and Water‐Heating Equipment |
| |
| *Primary Function | Primary function is space heating, secondary function is domestic water heating; primary function is domestic water heating, secondary function is space heating | |
| Volume (rated) |
| |
| Energy Factor (for those models whose primary function is water heating) |
| |
| Effective Space‐Heating Efficiency (CAAFUE) (for those models whose primary function is water heating) |
| |
| Annual Fuel Utilization Efficiency (AFUE) (for those models whose primary function is space heating) |
| |
| Effective Water‐Heating Efficiency (CAEF) (for those models whose primary function is space heating) |
| |
| Combined Annual Efficiency (CAE) |
| |
| Boilers |
| |
| *Type | Steam, hot water | |
| Natural Draft (for gas‐fired steam models manufactured on or after March 2, 2012 and ≥ 300,000 Btu/hour input only) | True, False | |
| Design | Copper, cast iron, other | |
| Automatic means for adjusting water temperature (small hot water boilers only) | True, False | |
| Input at Minimum Capacity1 |
| |
| Output at Minimum Capacity1 |
| |
| Combustion Efficiency (for models ≥ 300,000 Btu/hour input only) |
| |
| Thermal Efficiency (for models ≥ 300,000 Btu/hour input and < 2,500,000 Btu/hour input only) |
| |
| Thermal Efficiency (for models ≥ 2,500,000 Btu/hour input only)1 |
| |
| Standby Loss (for packaged boilers ≥ 300,000 Btu/hour input only)1 |
| |
| Standby Loss (for non‐packaged boilers ≥ 300,000 Btu/hour input only) 2 |
| |
| Thermal Efficiency at Minimum Capacity Rating (for non‐ packaged boilers ≥ 300,000 Btu/hour input only) |
| |
| AFUE (for models < 300,000 Btu/hour input only) |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Water Heaters
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| All Water Heaters |
| |
| *Energy Source | Natural gas, LPG, oil, electric resistance, heat pump | |
| Rated Volume (except booster heaters, hot water dispensers, and large instantaneous water heaters < 10 gallons capacity) |
| |
| Measured Volume (water heaters regulated under 10 C.F.R. section 431 subpart G as of January 1, 2017 only) |
| |
| Input Rating |
| |
| Heat Traps (for storage models only) | True, False | |
| Ozone Depleting Substance in Insulation1, 2 | True, False | |
| Ozone Depleting Substance in Refrigerant (for heat pump water heaters only) 1, 2 | True, False | |
| Constant burning pilot light (for large gas and oil models only) | True, False | |
| Mobile Home | True, False | |
| Water Heaters Regulated Under 10 C.F.R. section 430.32(d) |
| |
| Water Heater Type | Gas-fired storage, oil-fired storage, electric storage, tabletop, instantaneous gas-fired, instantaneous electric, grid-enabled | |
| First Hour Rating (for storage models only) |
| |
| Maximum Gallons Per Minute (for instantaneous models only) |
| |
| Recovery Efficiency |
| |
| Annual Electrical Energy Consumption |
| |
| Annual Fossil Fuel Energy Consumption (fossil fuel-fired models only) |
| |
| Draw Pattern | Very small, low, medium, high | |
| Uniform Energy Factor |
| |
| Pilot Light Energy Consumption (for gas instantaneous models only) |
| |
| Water Heaters Regulated Under 10 C.F.R. section 431.110 (EXCEPT residential-duty commercial water heaters) |
| |
| Water Heater Type | Electric storage, gas-fired storage, oil-fired storage, gas-fired instantaneous, gas-fired instantaneous | |
| Thermal Efficiency |
| |
| Standby Loss, %/hr. (electric models only) except for those models > 140 gallons for which exemption from standby loss standard is claimed) Note: this data requirement is mandatory for all models except instantaneous models in which the data requirement is voluntary |
| |
| Standby Loss Btu/hr. (fossil fuel fired models only) except for those models > 140 gallons for which exemption from standby loss standard is claimed) Note: this data requirement is mandatory for all models except instantaneous models in which the data requirement is voluntary |
| |
| Electrical Power During Recovery While Appliance is Heating (for storage models only) |
| |
| Electrical Power During Standby R-value of Insulation (for models > 140 gallons only) for which exemption from standby loss is claimed |
| |
| Flue Damper (for models > 140 gallons only) | True, False | |
| Fan Assisted Combustion (for models > 140 gallons only) | True, False | |
| Hot Water Supply Boiler (for instantaneous models with input ≥ 300,00 Btu/hour and ≤ 12,500,000 Btu/hour only) | True, False | |
| Residential Duty Commercial Water Heaters | Water Heater Type | Gas-fired storage, oil-fired storage electric instantaneous |
| Volume |
| |
| Input |
| |
| Draw Pattern | Very small, low, medium, high | |
| Uniform Energy Factor |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
|
Appliance |
Required Information |
Permissible Answers |
|
All Appliances |
* Manufacturer’s Name |
|
|
* Brand Name |
||
|
*Model Number |
||
|
Date model to be displayed |
||
|
Regulatory Status |
Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
|
Heat Pump Pool Heaters |
||
|
Heating Capacity at Standard Temperature Rating |
||
|
Readily‐Accessible on‐off Switch |
True, False | |
|
Coefficient of Performance at Standard Temperature Rating |
||
|
Heating Capacity at Low Temperature Rating |
||
|
Coefficient of Performance at Low Temperature Rating |
||
|
Average Coefficient of Performance (COP) at Standard Temperature Rating and Low Temperature Rating |
||
|
Refrigerant Type1, 2 |
Ozone‐depleting, non‐ozone‐ depleting | |
|
Other Pool Heaters |
||
|
Energy Source |
Natural gas, LPG, oil, electric resistance | |
|
Constant Burning Pilot Light (for gas models) |
True, False | |
|
Input |
||
|
Thermal Efficiency |
||
|
Pumps (data collection required for models manufactured on or after January 27, 2020 only) |
||
|
Equipment Class |
||
|
Total Pump Head in feet at BEP |
||
|
Total Pump Head in feet at nominal speed |
||
|
Volume per unit time (flow rate) in gallons per minute (gpm) at BEP |
||
|
Volume per unit time (flow rate) in gallons per minute (gpm) at nominal speed |
||
|
Nominal speed of rotation (rpm) |
||
|
Calculated driver power at each load point i (Pini) corrected to nominal speed, in horsepower (hp)3 |
||
|
Driver power input at each load point i (Pini), corrected to nominal speed, in horsepower, (hp)4 |
||
|
Driver power input (measured as the input power to the driver and controls)at each load point i (Pini), corrected to nominal speed, in horsepower, (hp)5 |
||
|
Full impeller diameter in inches |
||
|
PEICL calculated or tested4 |
||
|
PEIVL calculated or tested5 |
||
|
Number of stages tested RSV and ST pumps only |
||
|
Pump efficiency at BEP in in percent (%)1,3,4 |
||
|
Pump efficiency at BEP in PERCL1,3,4 |
||
|
Pump efficiency at BEP in percent (%)1,5 |
||
|
Pump efficiency at BEP in PERVL1,5 |
||
|
Pump configuration |
||
|
Nominal motor efficiency in percent (%)4,5,6 |
||
|
Motor horsepower (hp) for the motor with which the pump is being rated4,5,6 |
||
|
Bowl diameter in inches (ST pumps only)3,4,5 |
||
|
PEICL |
||
|
PEIVL |
||
|
C-value |
||
|
Residential Pool Pump and Motor Combinations and Replacement Residential Pool Pump Motors manufactured before July 19, 2021 |
||
|
Motor Construction is Split-Phase |
True, False | |
|
Motor Construction is Capacitor Start-Induction Run |
True, False | |
|
Motor Design |
Single‐speed, dual‐speed, multi‐speed, variable‐speed | |
|
Motor has Capability of Operating at Two or More Speeds with the Low Speed having a Rotation Rate that is No More than One‐Half of the Motor’s Maximum Rotation Rate |
True, False | |
|
Unit Type Residential |
Residential Pool Pump and Motor
Combination, | |
|
Pool Pump Motor Capacity |
||
|
Motor Service Factor |
||
|
Nameplate Horsepower |
||
|
Pump Control Speed (compliance with Section 1605.3(g)(5)(B)(2) of this Article) |
True, False | |
|
|
||
|
Dedicated-Purpose Pool Pumps manufactured on or after July 19, 2021 |
Dedicated-purpose pool pump product group |
Self-priming pool filter pumps with rated hydraulic horsepower of 0.711 hp <= hhp < 2.5 hp. Self-priming pool filter pumps with rated hydraulic horsepower of hhp <0.711 hp. Non-self-priming pool filter pumps. Pressure cleaner booster pumps. Integral cartridge-filter pool pumps. Integral sand-filter pool pumps. Waterfall pumps |
|
Freeze Protection Controls when Shipped |
Enabled, Disabled, Not applicable | |
|
Default Dry-Bulb Air Temperature setting (in degrees F) (when “Freeze Protection Controls when Shipped” = Enabled) |
||
|
Default Run-Time Setting (in minutes) (when “Freeze Protection Controls when Shipped” = Enabled) |
||
|
Default Motor Speed (in rpm) (when Freeze Protection Controls when “Freeze Protection Controls when Shipped” = Enabled) |
||
|
Default Motor Speed is More than ½ of the Maximum Available Speed (when Freeze Protection Controls when “Freeze Protection Controls when Shipped” = Enabled) |
True, False | |
|
Self-Priming Pool Filter pumps, Non-Self-Priming Pool Filter Pumps, Pressure Cleaner Booster pumps or Waterfall Pumps |
Weighted Energy Factor (WEF) in kilogallons per kilowatt-hour (kgal/kWh) |
|
|
Rated Hydraulic Horsepower in horsepower (hp) |
||
|
Speed Configuration for which the pump is being rated |
Single-speed, Two-speed, Multi speed, or Variable-speed | |
|
True Power Factor at High Load Point |
||
|
Dedicated-Purpose Pool Pump Nominal Motor Horsepower |
||
|
Dedicated-Purpose Pool Pump Motor Total Horsepower |
||
|
Dedicated-Purpose Pool Pump Service Factor |
||
|
Input Power at the High Flow Load Point (watts) |
||
|
Flow Rate at the High Flow Load Point (gpm) |
||
|
Speed at the High Flow Load Point (rpm) |
||
|
|
||
|
Self-priming pool filter pumps, Non-self-priming pool filter pumps or Pressure cleaner booster pumps |
Input Power at Maximum Rotating Speed (watts) |
|
|
Flow Rate at Maximum Rotating Speed (gpm) |
||
|
Speed at Maximum Rotating Speed (rpm) |
||
|
Self-priming pool filter pumps or Non-self-priming pool filter pumps |
||
|
True Power Factor at Low Load Point |
||
|
Pump Certified with NSF/ANSI 50-2015 |
True, False | |
|
Vertical Lift (in feet) (when “Pump Certified with NSF/ANSI 50-2015” = False) |
||
|
True Priming Time (in minutes) (when “Pump Certified with NSF/ANSI 50-2015” = False) |
||
|
Input Power at the Low Flow Load Point (watts) |
||
|
Flow Rate at the Low Flow Load Point (gpm) |
||
|
Speed at the Low Flow Load Point (rpm) |
||
|
|
||
|
Self-priming pool filter pumps, Non-self-priming pool filter pumps, or Waterfall Pumps |
Maximum Head (in feet) |
|
|
|
||
|
Integral cartridge-filter pool pumps or Integral sand-filter pool pumps |
Pool pump control is either integral to the pump or a separate component that is sold or offered for sale with the pump. |
True, False |
|
Maximum Run-Time (in hours) of the Pool Pump Control |
||
|
|
||
|
Replacement Dedicated-Purpose Pool Pump Motors manufactured on or after July 19, 2021 |
Replacement Dedicated-Purpose Pool Pump Motor is a Variable-speed replacement dedicated-purpose pool pump motor |
True, False |
|
Dedicated-purpose pool pump motor total horsepower (hp) |
||
|
Nominal efficiency at full-load and maximum operating speed (%) |
||
|
Motor speed at full-load and maximum operating speed (rpm) |
||
|
Motor torque at full-load and maximum operating speed (lb-ft) |
||
|
Input power at full-load and maximum operating speed (watts) |
||
|
Power factor at full-load and maximum operating speed (%) |
||
|
Motor phase |
Single-phase, polyphase | |
|
Sold with motor drive |
True, False | |
|
Meets requirements of 1605.3(g)(6)(D) (when “Sold with motor drive” = True) |
True, False | |
|
Freeze protection controls is shipped enabled |
Enabled, Disabled, Not applicable | |
|
Default dry bulb air temperature setting (“Freeze protection controls are shipped enabled”) |
||
|
Default motor speed (rpm) (when “Freeze protection controls are shipped enabled”) |
||
|
Default run time (minutes) (when “Freeze protection controls are shipped enabled”) |
||
|
Is the default motor speed more than 1/2 of the maximum available speed? (when “Freeze protection controls are shipped enabled”) |
True, False | |
|
|
||
|
Portable Electric Spas |
*Spa type |
Combination Spa, Exercise Spa, Inflatable Spa, Standard Spa |
|
*Tested Spa Cover Model Number |
||
|
Tested Spa Cover Manufacturer |
||
|
Rated Capacity (number of people) |
||
|
Rated Voltage (volts) |
||
|
Tested Spa Cover Is Insulated |
True, False | |
|
Spa Enclosure is Fully Insulated |
True, False | |
|
Spa includes a skimmer |
True, False | |
|
Maximum water Temperature setting is less than 1000 (for exercise spas and the exercise spa portion of combination spas only) |
True, False | |
|
Portable Electric Spa Rated Volume (gallons) (for standard spas, inflatable spas, and the standard spa portion of combination spas only) |
||
|
Exercise Spa Rated Volume (gallons) (for exercise spas, and the exercise spa portion of combination spas only) |
||
|
Portable Electric Spa Fill Volume (gallons) for standard spas, inflatable spas, and the standard spa portion of combination spas only) |
||
|
Exercise Spa Fill Volume (gallons) (for exercise spas, and the exercise spa portion of combination spas only) |
||
|
Portable Electric Spa Normalized Standby Power (Watts) (for standard spas, inflatable spas, and the standard spa portion of combination spas only) Exercise Spa Normalized Standby Power (Watts) (for exercise spas, and the exercise spa portion of combination spas only) |
||
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Plumbing Fittings |
| |
| *Type | Showerhead, lavatory faucet (independent or collective), public lavatory faucet, kitchen faucet, metering faucet (independent or collective), lavatory replacement aerator, kitchen replacement aerator, wash fountain, lift‐type tub spout diverter, turn‐type tub spout diverter, pull‐type tub spout diverter, push-type tub spout diverter | |
| Flow Rate |
| |
| Pulsating (for showerheads only) | True, False | |
| Minimum Flow rate at 45 psi and 80 psi (for showerheads manufactured on or after July 1, 2016 |
| |
| Minimum Flow rate at 20 psi (for showerheads manufactured on or after July 1, 2016 |
| |
| Rim Space (for wash fountains only) |
| |
| Tub Spout Leakage Rate When New |
| |
| Tub Spout Leakage Rate After 15,000 Cycles |
| |
| Commercial Pre‐rinse Spray Valves |
| |
| Product Class (required for models manufactured on or after January 28, 2019) | Product Class 1, Product Class 2, Product Class 3 | |
| Flow Rate (gpm) |
| |
| Spray force (ounce-force (ozf)) |
| |
|
|
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Plumbing Fixtures |
| |
| *Type | Blowout water closet, gravity tank type water closet, dual‐flush water closet, electromechanical hydraulic water closet, flushometer tank water closet, prison‐type urinal, prison‐type water closet, flushometer valve water closet, trough‐type urinal, wall‐mounted urinal, waterless urinal, other type urinal, vacuum type water closet | |
| Water Consumption (dual‐flush effective flush volume for dual‐flush water closet) |
| |
| Passes waste extraction test | True False | |
| Waste extraction value | grams | |
| Trough Length (trough‐type urinals only) |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Fluorescent Lamp Ballasts and Deep Dimming Lamp Ballasts
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Fluorescent Lamp Ballasts |
| |
| *Ballast Input Voltage | 120, 277, between 120 and 277 other (specify) | |
| *Number of Lamps |
| |
| *Type of Fluorescent Lamp | F34T12, F96T12/ES, F96T12HO/ES (2-foot U-shaped, 4-foot medium bipin, 4-foot miniature bipin high output, 4-foot miniature bipin standard output, 8-foot high output, 8-foot slimline | |
| Product Class (from U.S. DOE CCMS product template |
| |
| Designed for Dimming to 50% or Less of Maximum Output | True False | |
| Power Factor |
| |
| *Building Application | Commercial, designed (not classified as sign ballasts) to operate 8-foot high output lamps, designed and labeled as sign ballasts to operate 8-foot high output lamps, residential; not classified as residential, other | |
| Sign Ballasts | True False | |
| Input Power Watts |
| |
| Ballast Luminous Efficiency |
| |
| Circuit Design | Cathode cut‐out, electronic, magnetic | |
| *Start | Instant, programmed rapid | |
| Ballast Frequency | High frequency, low frequency, other | |
| Average Total Lamp Arc Power |
| |
|
| ||
|
Deep-Dimming Fluorescent Lamp Ballasts | *Ballast Input Voltage | 120, 277, other (specify) |
| *Number of Lamps |
| |
| *Lamp Type | T5, T8, other (specify) | |
| *Dimming Type | Continuous, stepped, individual lamp control, other (specify) | |
| *Control Type | 3-wire, 0-10 volts, digital communication, phase, other (specify) | |
| *Start Type | Instant start, rapid start, program start, other (specify) | |
| P100 |
| |
| Arc Power 100 |
| |
| P80 |
| |
| Arc Power 80 |
| |
| P50 |
| |
| Arc Power 50 |
| |
| BLE 100 |
| |
| BLE 80 |
| |
| BLE 50 |
| |
| P0 (standby mode power) |
| |
| Weighted Ballast Luminous efficacy |
| |
| Power Factor |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Lamps
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| State-regulated small diameter directional lamps | Base Type | |
| Lamp Type (examples PAR16, MR11, MR16, R) |
| |
| Lamp Power (Watts) |
| |
| Lamp Output (Lumens) |
| |
| Beam Angle |
| |
| Color Rendering Index (CRI) |
| |
| Combined CRI + Efficacy (only applies where efficacy < 80 LPW) |
| |
| Center Beam Candle Power (CBCP) |
| |
| Efficacy (Lumens per Watt) |
| |
| Correlated Color Temperature |
| |
| Rated Lifetime Test Completed |
| |
| Estimated rated Lifetime (hours) (when “Rated Lifetime Test Completed" = False | True False | |
| Rated Lifetime (hours) (when “Rated Lifetime Test Completed" = True) |
| |
| State-regulated Light Emitting Diode (LED) lamps | Base Type | |
| Lamp Shape | E12, E17, E26, GU-24, retrofit kit | |
| Dimmable | A, B, BA, C, CA, F, G, T, other | |
| Minimum Dimming level (%) (if Dimmable = True) | True, False | |
| Reduced Flicker Operation (if Dimmable = True) | True, False | |
| Correlated Color Temperature |
| |
| Duv |
| |
| Rated Lifetime Test Complete |
| |
| Estimated rated Lifetime (hours) (when “Rated Lifetime Test Completed" = False |
| |
| Rated Lifetime (hours) (when “Rated Lifetime Test Completed" = True) | Ambient, Elevated | |
| Lifetime test environment temperature |
| |
| Lamp Power (Watts) |
| |
| Lumen Output (Lumens) |
| |
| Efficacy (Lumens per Watt) |
| |
| Color Rendering Index (Ra) |
| |
| Compliance Score |
| |
| Power Factor |
| |
| Standby Mode |
| |
| Standby Power (Watts (if applicable) |
| |
| Connected network type (if applicable) | Wi-Fi, ZigBee, ANT, Bluetooth, RF, Wired, Other | |
| R1 |
| |
| R2 |
| |
| R3 |
| |
| R4 |
| |
| R5 |
| |
| R6 |
| |
| R7 |
| |
| R8 |
| |
| R92 |
| |
| Meets applicable luminous intensity distribution requirements | ENERGY STAR Omnidirectional, ENERGY STAR Decorative, none. | |
| Audible Noise at 100% output (decibels) (when “Dimmable” = True) |
| |
| Audible Noise at 20% output (decibels) (when “Dimmable” = True) |
| |
| Start Time2 |
| |
| 6000 hour lumen maintenance2 |
| |
| 6000 hour survival rate2 |
| |
| Projected time to L702 |
| |
| Dimming Control Compatibility (when “Dimmable” = True) | Forward, Phase cut control, reverse phase cut, powerline carrier, digital, 0‐10 VDC, other | |
| NEMA SSL 7A Compatible 2 (If compatible with forward phase cut dimmer control answer “True,” If not answer “False.”) | True, False | |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Emergency Lighting
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| * Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Emergency Lighting |
| |
| Light Source Type | LED, electroluminescent, fluorescent, incandescent, other (specify) | |
| Battery Backup | True, False | |
| Number of Faces |
| |
| Sign Format | Edge‐lit, panel, matrix, stencil, other (specify) | |
| Input Power Demand |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliance
Traffic Signal Modules
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| * Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Traffic Signal Modules for Vehicle control |
| |
| Module Color | Green, amber, red | |
| Module Type | Circular, arrow, lane control‐arrow, lane control‐X, pedestrian, other (specify) | |
| Modular Size (circular, arrow only) |
| |
| Nominal Wattage at 25° C |
| |
| Maximum Wattage at 74° C |
| |
| Traffic Signal Modules |
| |
| Module Type | Hand, Walking Person, walk, don’t walk, countdown (Specify) | |
| Power Consumption at 25° C |
| |
| Power Consumption at 74° C |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Luminaires and Torchieres
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Torchieres |
| |
| *Lamp Type of Upward‐Facing Lamp(s) | Screw‐based Incandescent, Halogen, Fluorescent Pin‐based, Other (specify) | |
| *Lamp Type of Side Lamp(s) | Screw‐based Incandescent, Halogen, Fluorescent Pin‐based, Other, None (specify) | |
| Total Number of Lamp Sockets |
| |
| Maximum Possible Power Demand, All Sockets (watts) |
| |
| Method of Insuring 190 Watt Maximum Power Consumption | Current‐limiting Device, Thermal Switch, Other (specify) | |
| Metal Halide Luminaires |
| |
| *Lamp Position (orientation) | Vertical Base‐Up, Vertical Base‐ Down, Horizontal, Universal, Other (specify) | |
| Lamp Rating, low (watts) |
| |
| Lamp Rating, high (watts) |
| |
| Outdoor Luminaire | True, False | |
| Compliance Option Used |
≥ 90/92% efficient ballast, ≥ 88% efficient ballast with integral control (Occupancy Sensor), ≥ 88% efficient ballast with integral control (Automatic Daylight Control), ≥ 88% efficient ballast labeled for relamping with only 150‐160 watt, 200‐215 watt, 290‐335 watt, or 336‐500 watt lamps | |
| Ballast Type [only applies to models manufactured on or after January 1, 2006] | Probe‐start electronic, probe‐start magnetic, pulse‐start electronic, pulse‐start magnetic, other (specify) | |
| Minimum Ballast Efficiency (percent) |
| |
| Integral Control Type (for integral control compliance method only) | Occupancy sensor, Automatic daylight control | |
| Integral Control Method (for integral control compliance method only) | Directly into luminaire housing Packaged and sold pre‐wired Integrated wireless radio controlled sensor | |
| Maximum relamping rated wattage on a factory‐installed label (watts) (for relamping wattage compliance method only) |
| |
| Packaged with efficient lamps (for relamping wattage compliance method only) | True, False | |
| Under‐Cabinet Fluorescent Fixtures (Luminaires) |
| |
| Lamp Length (inches) |
| |
| Number of Lamps for which Fixture (Luminaire) is Designed |
| |
| Ballast Efficacy Factor |
| |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Dishwashers
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | * Manufacturer’s Name |
|
| * Brand Name |
| |
| * Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Dishwashers |
| |
| *Type | Compact, standard | |
| * Number of Place Settings |
| |
| Water Heating Dishwasher | True, False | |
| Truncated Normal Cycle Capable | True, False | |
| Soil Sensing | True, False | |
| Maximum Energy Use |
| |
| Maximum Water Use |
| |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Clothes Washers
Data Submittal Requirements
| Appliance | Required Information | Possible Answers |
| All Appliances | ** Manufacturer’s Name |
|
| * Brand Name |
| |
| * Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Clothes Washers that are consumer products |
| |
| *Type | Front‐loading, top loading | |
| *Controls | Automatic, semi‐automatic, other (specify) | |
| *Axis | Horizontal, vertical | |
| Suds‐Saving | True, False | |
| Combination Washer/Dryer1 | True, False | |
| Clothes Container Compartment Capacity |
| |
| Power Consumption Per Cycle1 |
| |
| Water Consumption Per Cycle |
| |
| Integrated Modified Energy Factor |
| |
| Integrated Water Factor |
| |
| Remaining Moisture Content |
| |
| Corrected Remaining Moisture Content |
| |
| Commercial Clothes Washers |
| |
| *Type | Front‐loading, top loading | |
| *Controls | Automatic, semi‐automatic, other (specify) | |
| *Axis | Horizontal, vertical | |
| Suds‐Saving | True, False | |
| Combination Washer/Dryer | True, False | |
| Clothes Container Compartment Capacity |
| |
| Power Consumption Per Cycle |
| |
| Water Consumption Per Cycle |
| |
| Modified Energy Factor |
| |
| Water Factor (effective for models manufactured before January 1, 2018) |
| |
| Integrated Water Factor (effective for models manufactured on or after January 1, 2018) |
| |
| Remaining Moisture Content |
| |
| Corrected Remaining Moisture Content |
| |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Clothes Dryers
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | ** Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Clothes Dryers |
| |
| *Energy Source | Gas, electric | |
| *Drum Capacity |
| |
| *Voltage | 120, 240, other (specify) | |
| Combination Washer/Dryer1 | True, False | |
| Venting | Vented, ventless | |
| Combined Energy Factor |
| |
| Constant Burning Pilot Light (Gas models only) | True, False | |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Cooking Products and Food Service Equipment
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | ** Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Consumer Product Cooking Products |
| |
| *Type | Conventional range, conventional cooking top, conventional oven, microwave‐only oven, countertop convection microwave oven, built‐in microwave oven, over‐the‐ range convection microwave oven, combined cooking products, other (specify) | |
| *Energy Source | Gas, electric, microwave | |
| Electrical Supply Cord (for gas models only) | True, False | |
| *Constant Burning Pilot Light | True, False | |
| Annual Cooking Energy Consumption |
| |
| Clock Power Consumption (for gas conventional ovens only) |
| |
| Pilot Light Consumption (for gas conventional ovens only) |
| |
| Annual Secondary Energy Consumption (for gas conventional ovens only) |
| |
| Average Standby Power (data required for various microwave ovens manufactured on or after June 17, 2016 only) |
| |
| Off Mode Power1 |
| |
| On Mode Power |
| |
| Commercial Convection Ovens |
| |
| Energy Input Rate |
| |
| Idle Energy Consumption Rate |
| |
| Commercial Hot Food Holding Cabinets |
| |
| Measured Interior Volume (ft3) |
| |
| Energy Input Rate |
| |
| Idle Energy Consumption Rate |
| |
| Commercial Range Tops |
| |
| Energy Input Rate |
| |
| Cooking Energy Efficiency |
| |
| Test Cooking Vessel Diameter |
| |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Electric Motors
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | ** Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Electric Motors |
| |
| Type | NEMA Design A, NEMA Design B, IEC NEMA Design C, IEC, Design H, IEC Design N, Fire pump electric motor | |
| Voltage (V) |
| |
| Speed1 (RPM) |
| |
| Rated Horsepower (hp) |
| |
| Input Power (kW) |
| |
| Air Exchange | Open, enclosed | |
| Number of Poles | 2, 4, 6, 8 | |
| Nominal Full Load Efficiency (%) |
| |
| State-regulated Compressors | Isentropic Efficiency |
|
| Equipment Class | Rotary, lubricated, air-cooled, fixed-speed compressor; Rotary, lubricated, air-cooled, variable-speed compressor; Rotary lubricated, liquid-cooled, fixed-speed compressor; Rotary, lubricated, liquid-cooled, variable-speed compressor | |
| Full-load package isentropic efficiency (fixed-speed compressor only) or part-load package isentropic efficiency (variable-speed compressor only) |
| |
| Full-load actual volume flow rate (CFM) |
| |
| Compressor motor nominal horsepower (HP) |
| |
| Full-load operating pressure (psig) |
| |
| Maximum full-flow operating pressure (psig) |
| |
| Pressure ratio at full-load operating pressure |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Distribution Transformers
Data Submittal Requirements
| Appliance | Required Information | Permissible Answers |
| All Appliances | ** Manufacturer’s Name |
|
| * Brand Name |
| |
| *Model Number |
| |
| Date model to be displayed |
| |
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Distribution Transformers |
| |
| Distribution Transformer type (Data required for liquid‐immersed and medium‐voltage dry‐type on or after January 1, 2010 only) | Low‐voltage dry‐type; liquid‐ immersed; medium‐voltage dry‐type | |
| *Phase | 1, 3 | |
| kVa (BIL kVa for medium‐voltage dry‐ type) |
| |
| Rated Output Power |
| |
| Total Loss Power |
| |
| Efficiency (for medium‐voltage models, this will be the Efficiency at 20‐45 kV) |
| |
| Efficiency 2 (medium voltage models only, Efficiency at 46‐95 kV) |
| |
| Efficiency 3 (medium voltage models only, Efficiency at ≥ 96 kV) |
| |
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
Landscape Irrigation Equipment
Data Submittal Requirements
| Appliance | CFDHBG Required Information | Permissible Answers |
| All Appliances | ** Manufacturer’s Name | |
| * Brand Name | ||
| * Model Number | ||
| Date model to be displayed | ||
| Regulatory Status | Federally‐regulated consumer product, federally‐regulated commercial and industrial equipment, non‐federally‐regulated | |
| Spray Sprinkler Bodies | Regulation pressure (psi) | |
| Maximum operating pressure (psi) | ||
| Percent difference between the initial calibration flow rate and the maximum flow rate at any tested pressure level, averaged for the selected samples at the test pressure levels where the maximum flow rate occurred (percent) | ||
| Percent difference between the initial calibration flow rate and the flow rate at any tested pressure level, averaged across all pressure levels and all selected samples (percent) | ||
| Average outlet pressure at the initial calibration point of the selected samples (psi) |
* “Identifier” information as described in Section 1602(a)
1 = Voluntary for federally‐regulated appliances
2 = Voluntary for state‐regulated appliances
3 = Voluntary for single package vertical air conditioners and single package vertical heat pumps only.
3 = For pumps tested to the test methods prescribed in 10 C.F.R. Section III of appendix A to subpart Y of part 431.
4 = For pumps tested to the test methods prescribed in 10 C.F.R. Section IV or V of appendix A to subpart Y of part 431.
5 = For pumps tested to the test methods prescribed in 10 C.F.R. Section VI or VII of appendix A to subpart Y of part 431.
6 = For pumps sold with electric motors regulated by DOE's energy conservation standards for electric motors at § 431.25.
(3) for appliances for which there is an energy efficiency, energy consumption, energy design, water efficiency, water consumption, or water design standard in Section 1605.1, 1605.2, or Section 1605.3, of this Article that the appliance complies with the applicable standards;
-
(1) federally regulated organic light emitting diode (OLED) lamps,
- (2) federally regulated candelabra base incandescent lamps,
- (3) federally regulated intermediate base incandescent lamps,
- (4) traffic signal lamps, and
- (5) torchieres, and

In this subsection, “manufacturer” also includes a third party filing a statement under Section 1606(f) of this Article.
(1) Determination. The Executive Director shall determine whether a statement is complete, accurate, and in compliance with all applicable provisions of this Article, and whether the appliance for which the statement was submitted complies with all applicable standards in Section 1605.1, 1605.2, and Section 1605.3 of this Article.
If basic models are certified using an alternate test procedure established pursuant to Section 1603(c)(1) of this Article or for which the Executive Director has made a specification under either section 1603(c)(2)(A) or section 1603(c)(2)(B) of this Article, the Approved MAEDbS shall contain a second section which shall contain only those basic models for which certification to an applicable alternate test procedure is made.
2. have been removed from the Approved MAEDbS pursuant to sections 1606(e)(2) or 1608(c) of this Article.
(d) for appliances for which there is an energy efficiency, energy consumption, energy design, water consumption, water efficiency, or water design standard in section 1605.1, 1605.2, or Section 1605.3, of this Article that the model complies with the current applicable standards.
“This directory [insert parts if appropriate] has been approved by the California Energy Commission (Energy Commission) for determining compliance with its appliance efficiency regulations (Title 20, California Code of Regulations Sections 1601-1609) and its building standards (Title 24, California Code of Regulations, Part 6). UNLESS INDICATED OTHERWISE, any appliance listed in this directory [insert parts if appropriate] may be sold, offered for sale, or installed in new construction in California. For appliances manufactured by manufacturers participating in this directory, but who have not given authorization for data submittal to the Energy Commission, this directory cannot be used for determining compliance. For information about such appliances, appliances that are beyond the scope of this directory, or appliances produced by manufacturers who do not participate in this directory, please contact the Appliance Efficiency Program at: <appliances@energy.ca.gov>. Manufacturers not granting authorization for data submittal to the Energy Commission as of the publication date of this directory include [list all affected manufacturers]”; and
Manufacturers, and third parties or trade associations acting under sections 1606(a), 1606(f) and 1606(g) of this Article shall retain all data, forms, information, and all other records required by this Article concerning each appliance:
The Executive Director shall retain all data, forms, information, and all other records required by this Article concerning each appliance for at least 10 years after the record is initially filed or reconfirmed. Notwithstanding any other provision of this Article, MAEDbS listings that have not been confirmed within ten (10) years of original submittal or subsequent confirmation shall be presumed to be for products no longer in production and shall be automatically removed from the Approved MAEDbS and moved into the Archived MAEDbS.
The following documents are incorporated by reference in section 1606.
| Number | Title |
| CALIFORNIA ENERGY COMMISSION | |
|
|
|
| California Title 24, Part 6,Joint Appendix 8 JA-8 - 2015 | Qualification Requirements for High Efficacy Light Sources |
|
|
|
| Copies available from: | CALIFORNIA ENERGY COMMISSION |
|
|
ENERGY HOTLINE |
|
|
1516 NINTH STREET, MS-25 |
|
|
SACRAMENTO, CALIFORNIA 95814 |
|
|
PHONE: (916) 654-5106 |
|
|
FAX: (916) 654-4304 |
| FEDERAL STATUTES AND REGULATIONS | |
| C.F.R., Title 10, section 430 | Energy Conservation Program for Consumer Products |
| 430.23(ee) (Appendix BB to subpart B of part 430) (Jan. 1, 2017) | Uniform Test Method for Measuring the Input Power, Lumen Output, Lamp Efficacy, Correlated Color Temperature (CCT), Color Rendering Index (CRI), Power Factor, Time to Failure, and Standby Mode Power of Integrated Light-Emitting Diode (LED) Lamps |
| C.F.R., Title 10, section 430.23(m) (Appendix M1 to Subpart B of Part 430) | Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps |
|
C.F.R., Title 10, section 431.174 (Appendix A to Subpart J of Part 431) |
Uniform Test Method for the Measurement of Energy Consumption of Fans and Blowers Other Than Air Circulating Fans |
|
|
|
| Copies available from: | SUPERINTENDENT OF DOCUMENTS |
|
|
U.S. GOVERNMENT PRINTING OFFICE |
|
|
WASHINGTON D.C. 20402 |
|
|
http://www.ecfr.gov |
|
|
|
| AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI) | |
| AHRI Standard 680 (I-P)-2017 | 2017 Standard for Performance Rating of Residential Air Filter Equipment |
|
|
|
| AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL , INC (AMCA) | |
| ANSI/AMCA Standard 214-21 | Test Procedure for Calculating Fan Energy Index (FEI) for Commercial and Industrial Fans and Blowers (Approved by ANSI on March 1, 2021) |
|
|
|
| AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) | |
| ANSI/ASHRAE Standard 52.2-2017 | Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size |
|
|
|
| NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) | |
|
|
|
| NEMA SSL 7A (2013) | Qualification Requirements for High Efficacy Light Sources |
|
|
|
| Copies available from: | NATIONAL ELECTRIC MANFACTURERS |
|
|
ASSOCIATION |
|
|
1300 N. 17TH STREET, SUITE 1847 |
|
|
ROSSLYN, VA 22209 |
|
|
www.nema.org |
|
|
PHONE: (703) 841-3200 |
|
|
FAX: (703) 841-3300 |
Note: Authority cited: Sections 25213, 25218(e), 25401.9, 25402(a)-25402(c), and 25960, Public Resources Code; and sections 16, 26, and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015). Reference: Sections 25216.5(d), 25401.9, 25402(a)-25402(c), 25402.5.4, and 25960, Public Resources Code; and section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).
- HISTORY
1. Order of Repeal of subsections (c)(7)(F)1, (c)(7)(F)2 and (d) filed 6-3-85 by OAL pursuant to Government Code section 11349.7; effective thirtieth day thereafter (Register 85, No. 26). For prior history, see Register 83, No. 18.
2. Amendment of subsection (c)(7)(C) filed 3-3-86; effective thirtieth day thereafter (Register 86, No. 10).
3. Amendment filed 7-20-87; operative 8-19-87 (Register 87, No. 30).
4. Amendment filed 8-29-88; operative 9-28-88 (Register 88, No. 37).
5. Amendment filed 6-5-90; operative 7-5-90 (Register 90, No. 31).
6. Amendment of subsections (a), (b), (d) and (f) filed 11-6-91; operative 12-6-91 (Register 92, No. 9).
7. Amendment of Table J and subsection (b)(9) filed 7-23-92; operative 8-24-92 (Register 92, No. 35).
8. Repealer and new section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).
9. Amendment of subsections (a) and (a)(3)(D)-(a)(3)(E)3.b., Table U and subsection (b)(2)(A) filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.
10. Certificate of Compliance as to 4-1-2003 order, including amendment of Table U footnote, transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).
11. Amendment of Table U, subdivision P, filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).
12. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).
13. Amendment of Exceptions to subsection (a) and subsection (a)(2)(A), repealer of Exception and new Exceptions 1-3 to subsection (a)(3)(D), amendment of Table V, parts A, C, D, G, K, N and U, new subsections (a)(4)(A)4.-(a)(4)(A)5.h., amendment of subsection (c)(1)(A) and new subsections (f)(1)(F)-(f)(1)(F)4. filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
14. Amendment of Table V-D, V-F, V-G, V-K and V-N and subsection (a)(4)(A)5.f., and amendment of Note filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).
15. Amendment of subsection (a) - Table V and subsections (b)(2)-(b)(2)(A) filed 8-22-2007; operative 9-17-2007 pursuant to Government Code section 11343.4 (Register 2007, No. 34).
16. Amendment of subsection (a) - Table V filed 11-29-2007; operative 12-29-2007 (Register 2007, No. 48).
17. Amendment of subsection (a), and subdivisions thereof, including redesignation of former Table V as new Table X, amendment of subsections (c)(1)(A)-(c)(2), (e)(1)-(2), (f)(1)(A)1. and (f)(1)(F) filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
18. Amendment of subsection (a) - Table X-K and X-N, new subsection (j) and amendment of Note filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
19. Amendment of subsection (a) - Table X-V and new subsections (a)(4)(A)5.j.-k. filed 9-1-2010; operative 1-1-2011 (Register 2010, No. 36).
20. New Exception 4 to subsection (a)(3)(D), amendment of subsection (a) - Table X-L and X-W and new subsection (a)(4)(A)4.m. filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).
21. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).
22. Amendment of subsection (a) - Table X-H and Table X-I, new subsection (a)(4)(A)4.j. and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5-15-2015 (Register 2015, No. 20).
23. Amendment of subsection (a)(3)(E) - Table X-H filed 8-20-2015; operative 8-20-2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).
24. Amendment of subsection (a)(3)(E) - Table X filed 6-30-2016; operative 7-1-2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).
25. Amendment of subsection (k) and list of documents incorporated by reference filed 11-1-2016; operative 1-1-2017 (Register 2016, No. 45).
26. Amendment of subsection (a)(3)(E) - Table X-G filed 3-27-2017 as an emergency; operative 3-27-2017 (Register 2017, No. 13). A Certificate of Compliance must be transmitted to OAL by 9-25-2017 or emergency language will be repealed by operation of law on the following day.
27. Amendment of subsection (a)(3)(E) - Table X-C filed 3-27-2017 as an emergency; operative 3-27-2017 (Register 2017, No. 13). A Certificate of Compliance must be transmitted to OAL by 9-25-2017 or emergency language will be repealed by operation of law on the following day.
28. Amendment of Table X, part V and new subsections (e)(3) and (k)-(k)(2) filed 8-22-2017; operative 10-1-2017 (Register 2017, No. 34).
29. Change without regulatory effect amending subsection (a)(4)g. filed 9-11-2017 pursuant to section 100, title 1, California Code of Regulations (Register 2017, No. 37).
30. Certificate of Compliance as to 3-27-2017 order transmitted to OAL 8-25-2017 and filed 10-5-2017 (Register 2017, No. 40).
31. Amendment of subsection (a)(3)(E)3.b., Table X-V and subsection (k)(2) filed 1-25-2018; operative 1-25-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 4).
32. Amendment of Table X-G filed 7-19-2018; operative 10-1-2018 (Register 2018, No. 29).
33. Amendment of section heading, section and Note filed 9-26-2018; operative 10-1-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).
34. Editorial correction of subsections (a) and (a)(3)(C) and Table X - sections C, G, J, S and T (Register 2018, No. 45).
35. Editorial correction of Table X (Register 2019, No. 11).
36. Change without regulatory effect amending subsection (a), Table X and list of documents incorporated by reference filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).
37. Amendment of subsection (a)(1), new subsection (a)(1)(H) and amendment of Table X filed 3-18-2019; operative 3-18-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 12).
38. Amendment of subsections (a), (a)(3)(A) and (a)(3)(C) and Table X and new subsection (a)(4)(A)4.i. filed 6-10-2019; operative 6-10-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).
39. Amendment of Table X adding new section (X) and amendment of Note filed 10-7-2019; operative 10-1-2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).
40. Amendment of EXCEPTIONS to subsection (a) and Table X - section K filed 12-24-2019; operative 1-1-2020 (Register 2019, No. 52).
41. Amendment of subsection (a)(3)(A) adding Exceptions 2. and 3., amendment of Table X - section G and subsection (a)(4)(A)5.g. and new subsection (a)(4)(A)5.i. filed 9-21-2020; operative 1-1-2021 (Register 2020, No. 39). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-66-20.
42. Amendment of Table X, section V filed 2-3-2021; operative 12-9-2021 pursuant to Government Code section 11343.4(b)(1) and Public Resources Code section 25402(c)(1) (Register 2021, No. 6).
43. Amendment of subsections (a)(3)(A), amendment of Table X, sections A, D, G, L and X, amendment of subsections (c)(4)(A)4.h.-i., (e)(3), (f)(1)(A)1. and (j)(1) filed 3-16-2021; operative 3-16-2021 pursuant to Government Code section 11343.4(b)(3) (Register 2021, No. 12). (Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20.)
44. Change without regulatory effect amending subsection (a)(3)(C) - Exception 3., Table X, section V and subsections (a)(4)(A)5.i., (c)-(c)(1) and (h)(1)(A) filed 7-12-2021 pursuant to section 100, title 1, California Code of Regulations (Register 2021, No. 29).
45. Amendment of Table X - section G filed 9-8-2021; operative 1-1-2022 (Register 2021, No. 37).
46. Change without regulatory effect amending subsections (a)(1)(E), (a)(2)(B), (d)(1), (g)(3) and (h)(3) filed 8-24-2022 pursuant to section 100, title 1, California Code of Regulations (Register 2022, No. 34).
47. Amendment of Table X section D adding “Commercial and Industrial Fans and Blowers” filed 1-17-2023; operative 11-16-2023 (Register 2023, No. 3).
48. New subsection (a)(1)(I), amendment of Table X -- section C and amendment of list of documents incorporated by reference filed 4-7-2023; operative 7-1-2024 (Register 2023, No. 14).
49. Repealer of subsection (n)(3) - Portable luminaires and amendment of subsection (a)(4) - EXCEPTIONS to section 1606(a)(4)(A)4. filed 4-25-2023; operative 4-25-2023 pursuant to Government Code section 11343.4(b)(3) (Register 2023, No. 17).
50. Amendment filed 7-18-2024; operative 7-18-2024 pursuant to Government Code section 11343.4(b)(3) (Register 2024, No. 29).
This database is current through 12/5/25 Register 2025, No. 49.
Cal. Admin. Code tit. 20, § 1606, 20 CA ADC § 1606
